34. Install 7 dry cap screws in
end cap. Pretighten cap
screws to 17Nm [150 lb-in],
then torque screws to
28-34 Nm [250-300 lb-in] in
sequence shown in
figure 29.
1
3
5
7
2
4
6
Figure 29
Assembly
Figure 28
31 Install back-up ring and seal
ring in gerotor star.
32. Lubricate and install 72,6 mm
[2.86 in.] ID seal in gerotor
(meter).
33. Install end cap on gerotor,
aligning holes.
Screw, Cap, Hex Head
Cap, End
Seal
Seal, Ring (metal)
Low Slip
Sealed
Gerotor
Star
Ring, Back-up (rubber)
Gerotor
Groove cross section
w/ rings