Eaton Box 1 Instructions And Operation Download Page 5

ote:

N

source drawing reference wiring diagram 286979 .

ote:

N

For kits with a green OFF light, an additional top added 

NC auxiliary is needed to be supplied by the customer .

NO4

NO3

STOP/OFF

START/ON
OX

2/13

3/14

R1

M

A2

A1

M

X2

X1

RUN

R

1 2

96

95

OL

X2

X1

OFF

G

1 2

T1

62

61

M

98

97

OL

1

2

1 2

1 2

BLK/RED

BLK/RED

RED

RED

RED

RED

BLK/WHT

BLK/WHT

RED

BLK

RED
(BLU IF DC)

RED
(BLU/WHT IF DC)

DASHED COMPONENTS ARE OPTIONAL

USE AS REQUIRED FOR SELECTED COVER CONTROL OPTIONS

REFERENCE NOTES BELOW FOR CONTROL POWER WIRING OPTIONS

1/L1 OR SEPARATE CONTROL

3/L2 OR SEPARATE CONTROL

RED

RED

STOP/START OR OFF/ON 2-POSTION SELECTOR SWITCH

OPTIONS SHOWN: RUN LIGHT, AND OFF LIGHT

WIRING FOR DC STARTERS ONLY

A1

M HOLD

A2

M PICKUP

X2

X1

RUN

R

R1

M LATE OPENING

96

95

OL

98

97

OL

BLU

RED

BLK/RED

BLK/RED

BLU

BLU

T1

62

61

M

T1

54

53

M

4

3

CONTROL POWER WIRING NOTES

CAUTION

READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL
MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.

: CONNECT SEPARATE CONTROL LINES TO THE

NO. 61 TERMINAL ON THE TOP ADDER AUX. AND TO THE NO. 96 TERMINAL ON THE
OVERLOAD RELAY.

: REMOVE WIRE "C2" IF SUPPLIED. IF WIRE

"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE NO. 96 TERMINAL ON THE OVERLOAD RELAY.

: ADD WIRE "C2" IF NOT SUPPLIED. ADD

CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 TERMINAL ON THE TOP ADDER
AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM.

: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.

SEPARATE CONTROL POWER

COMMON CONTROL POWER

FOR COIL VOLTAGES 120V AND LESS

FOR COIL VOLTAGES GREATER THAN 120V

FOR COIL VOLTAGES 120V AND LESS

FOR COIL VOLTAGES GREATER THAN 120V

OPTION FOR RUN LIGHT (RED TYPICAL)

REQUIRED FOR 480V OPTION

1NO-1NC TOP ADDER AUX INCLUDED FOR COIL VOLTAGES 120V AND
LESS FOR SEPARATE CONTROL.  FOR HIGHER COIL VOLTAGES, 1/L1 IS
CONNECTED TO PILOT DEVICE TERMINAL FOR COMMON CONTROL

1

2

3

4

OPTION FOR OFF LIGHT (GREEN TYPICAL) (INCLUDES 1NO-1NC AUX)

BLK/RED

X2

X1

OFF

G

1 2

1 2

RED

RED

BLK/WHT

BLK/WHT

T1

62

61

M

X2

X1

RUN

R

1 2

1 2

RED

RED

1

2

DASHED COMPONENTS ARE OPTIONAL

USE AS REQUIRED FOR SELECTED COVER CONTROL OPTIONS

REFERENCE NOTES BELOW FOR CONTROL POWER WIRING OPTIONS

1/L1 OR SEPARATE CONTROL

3/L2 OR SEPARATE CONTROL

RED

YEL

RED

(BLU/WHT IF DC)

RED

(BLU/WHT IF DC)

NO4

NO3

XOO

HAND/TEST 0 AUTO

NO4

NO3

OOX

A2

A1

M

96

95

OL

98

97

OL

2/13

3/14

R1

M

REMOTE

SWITCH

HAND/OFF/AUTO OR TEST/OFF/AUTO 3-POSTION SELECTOR SWITCH

OPTIONS SHOWN: RUN LIGHT, AND OFF LIGHT

WIRING FOR DC STARTERS ONLY

A1

M HOLD

A2

M PICKUP

X2

X1

RUN

R

R1

M LATE OPENING

96

95

OL

98

97

OL

BLU

RED

BLK/RED

BLK/RED

BLU

BLU

T1

62

61

M

T1

54

53

M

4

3

CONTROL POWER WIRING NOTES

CAUTION

READ AND FOLLOW INSTRUCTIONS PRIOR TO WIRING OR CONNECTING POWER!
THIS PRODUCT CAN BE FACTORY OR FIELD CONFIGURED FOR MULTIPLE CONTROL
MODES OR CONTROL VOLTAGES. CHECK NAMEPLATE FOR COIL VOLTAGE.

: CONNECT SEPARATE CONTROL LINES TO THE

NO. 61 TERMINAL ON THE TOP ADDER AUX. AND TO THE NO. 96 TERMINAL ON THE
OVERLOAD RELAY.

: REMOVE WIRE "C2" IF SUPPLIED. IF WIRE

"C1" IS TERMINATED ON L1, DISCONNECT FROM L1. CONNECT SEPARATE CONTROL
LINES TO THE "C1" WIRE OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM
AND TO THE NO. 96 TERMINAL ON THE OVERLOAD RELAY.

: ADD WIRE "C2" IF NOT SUPPLIED. ADD

CONNECTOR BETWEEN L1 TERMINAL AND THE NO. 61 TERMINAL ON THE TOP ADDER
AUX. OR APPROPRIATE PILOT DEVICE TERMINAL PER DIAGRAM.

: ADD WIRE "C1" AND "C2" IF NOT SUPPLIED.

SEPARATE CONTROL POWER

COMMON CONTROL POWER

FOR COIL VOLTAGES 120V AND LESS

FOR COIL VOLTAGES GREATER THAN 120V

FOR COIL VOLTAGES 120V AND LESS

FOR COIL VOLTAGES GREATER THAN 120V

OPTION FOR RUN LIGHT (RED TYPICAL)

REQUIRED FOR 480V OPTION

1NO-1NC TOP ADDER AUX INCLUDED FOR COIL VOLTAGES 120V AND
LESS FOR SEPARATE CONTROL.  FOR HIGHER COIL VOLTAGES, 1/L1 IS
CONNECTED TO PILOT DEVICE TERMINAL FOR COMMON CONTROL

1

2

3

4

OPTION FOR OFF LIGHT (GREEN TYPICAL) (INCLUDES 1NO-1NC AUX)

5

Instructions and Operation 

P52899

Effective May 2015

Box 1 Non-Combination Enclosed Control 

and C600M Cover Control Kit Wiring

EATON

 www.eaton.com

Summary of Contents for Box 1

Page 1: ...nstallation 2 Starter Contactor Wiring Diagrams 3 C600M Kit Wiring Instructions 4 Starter Contactor Mounting Locations 8 Enclosures without Starters or Contactors 9 Reset Rod Kits 9 Reset Rod Installa...

Page 2: ...trol kit see instructions below 1 Remove rectangular blank cover by pushing on the blank cover from the back side 2 Discard blank cover Cover Control Installation 3 Using the included mounting screws...

Page 3: ...C Starters and Contactors Wiring Diagrams FVR NEMA and IEC Starters and Contactors 3 Instructions and Operation P52899 Effective May 2015 Box 1 Non Combination Enclosed Control and C600M Cover Control...

Page 4: ...ROL VOLTAGES CHECK NAMEPLATE FOR COIL VOLTAGE CONNECT SEPARATE CONTROL LINES TO THE NO 61 TERMINAL ON THE TOP ADDER AUX AND TO THE NO 96 TERMINAL ON THE OVERLOAD RELAY REMOVE WIRE C2 IF SUPPLIED IF WI...

Page 5: ...DEVICE TERMINAL FOR COMMON CONTROL 1 2 3 4 OPTION FOR OFF LIGHT GREEN TYPICAL INCLUDES 1NO 1NC AUX BLK RED X2 X1 OFF G 1 2 1 2 RED RED BLK WHT BLK WHT T1 62 61 M X2 X1 RUN R 1 2 1 2 RED RED 1 2 DASHED...

Page 6: ...ON CONTROL 5 T1 62 61 M T1 54 53 M 5 3 R F OL F FWD UP 0 REV DWN RED BLK REV OFF FWD OR DWN OFF UP 3 POSITION SELECTOR SWITCH OPTIONS SHOWN REV DWN LIGHT AND FWD UP LIGHT RED BLU IF DC RED BLU IF DC B...

Page 7: ...TE PILOT DEVICE TERMINAL PER DIAGRAM AND TO THE NO 96 TERMINAL ON THE OVERLOAD RELAY ADD WIRE C2 IF NOT SUPPLIED ADD CONNECTOR BETWEEN L1 TERMINAL AND THE NO 61 OR NO 63 TERMINAL PER DIAGRAM ON THE TO...

Page 8: ...op Location AN16AN AN19AN AN16BN AN19BN AN16DN AN19DN AN19GN All Other 00 00 0 0 1 1 2 00 2 14B 14B 14B 14B 14A 14A 14A 1 Starter Contactor Mounting Locations Example If you want to mount a AN16AN you...

Page 9: ...length 1 56 C899B156 A27 B27 Fixed Overload Empty Box 1 Enclosure with 1 56 inch reset rod length 1 68 C899B168 ECN_C306 Size 00 0 1 A25 B25 C306 Empty Box 1 Enclosure with 1 68 inch reset rod length...

Page 10: ...SSESSION OF THIS DOCUMENT THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR...