1.  From the top of the box cover, insert the M22 button into the 

box cover.

2.  From the bottom of the cover, tighten the nut onto M22 but-

ton.

3.  From the bottom of the cover, snap the shroud (if supplied) 

cut to the appropriate length for the reset rod into the M22 

button.

4.  If the reset paddle is not already assembled to the required 

reset rod (see Reset Rod Kit table), assemble as shown by 

inserting reset rod into reset paddle.

5.  From the bottom of the cover, snap the required reset rod 

into M22 button.  The flat side of the paddle should face 

away from the box cover’s rectangular opening with the 

“Up” arrow facing toward the top of the box.

Reset Rod Installation

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

A

A

B

B

C

C

D

D

EATON CORPORATION - CONFIDENTIAL AND PROPRIETARY

NOTICE TO PERSONS RECEIVING THIS DOCUMENT AND/OR TECHNICAL INFORMATION

THIS DOCUMENT, INCLUDING THE DRAWING AND INFORMATION CONTAINED THEREON, IS CONFIDENTIAL AND IS THE 

EXCLUSIVE PROPERTY OF EATON CORPORATION, AND IS MERELY ON LOAN AND SUBJECT TO RECALL BY EATON AT ANY TIME.

BY TAKING POSSESSION OF THIS DOCUMENT, THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT

BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE

COPIED OR OTHERWISE REPRODUCED WITHOUT THE PRIOR WRITTEN CONSENT OF EATON. IN THE CASE OF CONFLICTING

CONTRACTUAL PROVISIONS, THIS NOTICE SHALL GOVERN THE STATUS OF THIS DOCUMENT.

C            Eaton Corporation, All Rights Reserved

TITLE

DRAWING

NUMBER

SIZE

D

CHANGE RESPONSIBILITY

REVISION

CLASS CODE

SHEET

SCALE

OF

DATE (YYYY/MM/DD)

DRAFTER/DESIGNER

MANUFACTURING

REVISION DESCRIPTION

DIMENSIONS IN

UNLESS OTHERWISE SPECIFIED

DRAWING IN ACCORDANCE WITH

ASME Y14.5M-1994

ENG/MFG REFERENCE

X.XX+/-XX

ST

SYMBOLS PER

468-1143

J. UPHAUS

ENGINEERING APPROVED

ECO#

INCHES

X.X

X.XX

X.XXX   

     

X.X°

±

0.1

±

0.02

±

0.005

±

±

.5°

NA

N/A

2015/03/18

J. UPHAUS

N/A

N/A

N/A

N/A

P52899 RESET ASSEMBLY VIEW

 

 

N/A

NTS

2015

Eaton

1000 Eaton Boulevard

Cleveland, OH 44122

United States

Eaton .com

© 2014 Eaton

All Rights Reserved

Publication No . P52899 / 002

May 2015

Eaton is a registered trademark .

All other trademarks are property  

of their respective owners .

Box 1 Non-Combination Enclosed Control 

and C600M Cover Control Kit Wiring

Instructions and Operation 

P52899

Effective May 2015

Summary of Contents for Box 1

Page 1: ...nstallation 2 Starter Contactor Wiring Diagrams 3 C600M Kit Wiring Instructions 4 Starter Contactor Mounting Locations 8 Enclosures without Starters or Contactors 9 Reset Rod Kits 9 Reset Rod Installa...

Page 2: ...trol kit see instructions below 1 Remove rectangular blank cover by pushing on the blank cover from the back side 2 Discard blank cover Cover Control Installation 3 Using the included mounting screws...

Page 3: ...C Starters and Contactors Wiring Diagrams FVR NEMA and IEC Starters and Contactors 3 Instructions and Operation P52899 Effective May 2015 Box 1 Non Combination Enclosed Control and C600M Cover Control...

Page 4: ...ROL VOLTAGES CHECK NAMEPLATE FOR COIL VOLTAGE CONNECT SEPARATE CONTROL LINES TO THE NO 61 TERMINAL ON THE TOP ADDER AUX AND TO THE NO 96 TERMINAL ON THE OVERLOAD RELAY REMOVE WIRE C2 IF SUPPLIED IF WI...

Page 5: ...DEVICE TERMINAL FOR COMMON CONTROL 1 2 3 4 OPTION FOR OFF LIGHT GREEN TYPICAL INCLUDES 1NO 1NC AUX BLK RED X2 X1 OFF G 1 2 1 2 RED RED BLK WHT BLK WHT T1 62 61 M X2 X1 RUN R 1 2 1 2 RED RED 1 2 DASHED...

Page 6: ...ON CONTROL 5 T1 62 61 M T1 54 53 M 5 3 R F OL F FWD UP 0 REV DWN RED BLK REV OFF FWD OR DWN OFF UP 3 POSITION SELECTOR SWITCH OPTIONS SHOWN REV DWN LIGHT AND FWD UP LIGHT RED BLU IF DC RED BLU IF DC B...

Page 7: ...TE PILOT DEVICE TERMINAL PER DIAGRAM AND TO THE NO 96 TERMINAL ON THE OVERLOAD RELAY ADD WIRE C2 IF NOT SUPPLIED ADD CONNECTOR BETWEEN L1 TERMINAL AND THE NO 61 OR NO 63 TERMINAL PER DIAGRAM ON THE TO...

Page 8: ...op Location AN16AN AN19AN AN16BN AN19BN AN16DN AN19DN AN19GN All Other 00 00 0 0 1 1 2 00 2 14B 14B 14B 14B 14A 14A 14A 1 Starter Contactor Mounting Locations Example If you want to mount a AN16AN you...

Page 9: ...length 1 56 C899B156 A27 B27 Fixed Overload Empty Box 1 Enclosure with 1 56 inch reset rod length 1 68 C899B168 ECN_C306 Size 00 0 1 A25 B25 C306 Empty Box 1 Enclosure with 1 68 inch reset rod length...

Page 10: ...SSESSION OF THIS DOCUMENT THE RECIPIENT ACKNOWLEDGES AND AGREES THAT THIS DOCUMENT CANNOT BE USED IN ANY MANNER ADVERSE TO THE INTERESTS OF EATON AND THAT NO PORTION OF THIS DOCUMENT MAY BE COPIED OR...

Reviews: