Mounting- and Operating instructions AT-S+ ESF30 KV

   40071860413_A   October 2021   www.eaton.com

1 Important notes

1 Important notes

1.1 General information

Installation work may only be carried out by qualified elec-

tricians (cf. DIN VDE 0105 part 1, the accident prevention 

regulation Accident Prevention Regulation BGV A3 of the 

main of the Employer‘s Liability Insurance Associations or 

analogous regulations and directives of the country in which 

the system is installed and operated). Other persons may 

carry out the activities described in this manual only if they 

have been properly and professionally instructed, and have 

received proper instruction,
•   their tasks and activities have been precisely defined and 

understood.

•   the activities are carried out under the supervision and 

control of  competent personnel.

Observe:

•   the requirements of the usability certificates

•   the regulations of the MLAR, MBO, technical building 

regulations

•   the extended documentation obligations resulting from 

the  amendment of the MBO.

•   all instructions for maintenance contracts!

•   the instructions in the safety data sheets for building 

materials!

•   Keep the swivel area of the door free and always keep 

the door closed!

•  Only use the system when it is in proper condition!

•   For installation, operation and maintenance, the respective 

accident prevention and DIN/VDE regulations must be 

observed.

•  that the suitability of the product and any additional expert 

opinions must be checked on a project-specific basis during 

the planning phase. The area of application of the products, 

e.g. according to the usability certificate, must be checked 

by the customer.

•  building regulations (especially building regulations) and 

building requirements!

•  Impairment of the stability of the system when the doors 

are open is to be expected if the system has not yet been 

screwed to the building structure.

IMPORTANT NOTE: 

The operator is required by the applicant of a general building 

authority approval/general type approval general building 

approval must inform the operator in writing that the fire 

protection system only meets the requirements of fire 

resistance only when closed. This has been done herewith.
•   Improper installation may impair the protective function.

•   Screw connections to the building may only be made with 

approved,  suitable screws/dowels. 

•   The suitability of the screws/dowels must be checked 

depending on the building.

•   The enclosures must not be glued, painted or otherwise 

coated.

•   They must not be damaged (holes, screws) on the corpus. 

(holes, screws). The locking systems must not be changed 

or exchanged.

•   When working with these assembly and installation 

instructions the following instructions, marked with an at-

tention symbol and a password, the following instructions 

to be observed.

1.2 Explanation of symbols

Important safety instructions in these operating instructions 

are marked with symbols.

  NOTE:

Gives important tips and advice on the procedure or handling 

of the described devices or system parts.

  ATTENTION!

Indicates sources of danger that may be the cause of da-

mage to plants or plant damage to installations or parts of 

installations as well as environmental can be.

   WARNING!

Draws attention to sources of danger that can cause injury 

to persons or serious damage to installations or parts of 

installations and serious environmental damage.

  DANGER!

Draws attention to sources of danger that may cause life-

threatening injuries to persons or serious damage, which 

indirectly pose a danger to persons or the environment.

   WARNING!

The illustrations in these assembly and installation instruc-

tions are only intended to illustrate the described circum-

stances.
Wherever
•  work is carried out with dimensional accuracy or

•   precise drawings adapted to the special features on site, 

the drawings are required, the drawings that have been dra-

wings that have been specially prepared for the installation.

   WARNING!

Only carry out work for which you have sufficient profes-

sional and have been instructed in the local and operational 

conditions! 
In the case of extensions, conversions, repairs or work 

that is work that is not described in these instructions are 

to be carried out by specially trained specialist and service 

personnel (of the manufacturer CEAG or sales and service 

companies authorised by CEAG)! 

Summary of Contents for AT-S PLus ESF30 KV

Page 1: ...d Operating instructions AT S ESF30 KV Mounting and Operating instructions Small distribution board with function maintenance type AT S ESF30 KV Target group qualified electricians according to DIN VDE 0105 Part 1 ...

Page 2: ...F30 SU5 and SU4 IO 6 4 3 2 Drawings AT S ESF30 SU5 6 4 4 AT S ESF30 SU4 6 4 4 1 Components AT S ESF30 SU4 6 4 4 2 Drawings AT S ESF30 SU4 6 4 5 AT S ESF30 SU2 7 4 5 1 Components AT S ESF30 SU2 7 4 5 2 Drawings AT S ESF30 SU2 7 4 6 AT S ESF30 SOU5 8 4 6 1 Components AT S ESF30 SOU5 8 4 6 2 Drawings AT S ESF30 SOU5 8 4 7 AT S ESF30 SOU3 8 4 7 1 Components AT S ESF30 SOU3 8 4 7 2 Drawings AT S ESF30 ...

Page 3: ...ng that the fire protection system only meets the requirements of fire resistance only when closed This has been done herewith Improper installation may impair the protective function Screw connections to the building may only be made with approved suitable screws dowels The suitability of the screws dowels must be checked depending on the building The enclosures must not be glued painted or other...

Page 4: ... the right to make technical changes that serve to improve the enclosures or that are caused by legal changes even without separate notification All information and notes in these assembly and installation instructions have been compiled taking into account the ap plicable regulations the state of the art and our many years of knowledge and experience The assembly and installation instructions mus...

Page 5: ...ngs consist of coated non metallic plate shaped components and are light grey on the outside similar to RAL7035 The edges are colour contrasting Fire insulation is provided by processing fire protection panels in accordance with DIN 4102 The cable penetrations have a fire resistance duration of more than 30 minutes if the cables are inserted correctly and are smoke tight in the sense of a cable sm...

Page 6: ...itch over modules SU S 2 x 6 A 1 1 4 4 2 Drawings AT S ESF30 SU4 4 4 AT S ESF30 SU4 4 4 1 Components AT S ESF30 SU4 1 Enclosure 2 Switch over modules SU S 2 x 6 A 1 1228 478 295 A A 200 950 139 139 139 139 A A 200 950 139 139 139 139 928 A A A A 1 5 295 478 200 139 139 139 928 A A A A 1 5 295 478 200 139 139 139 139 650 928 A A A A 1 5 295 478 200 139 139 139 1228 478 295 A A 200 950 139 139 139 1...

Page 7: ...eaton com 4 Layout 4 5 2 Drawings AT S ESF30 SU2 4 5 AT S ESF30 SU2 4 5 1 Components AT S ESF30 SU2 1 Enclosure 2 Switch over modules SU S 2 x 6 A 1 778 A A A A 1 5 295 478 200 139 139 139 500 139 A A A A 1 5 478 200 139 139 139 500 139 778 A A A A 1 5 295 478 200 139 139 139 500 139 ...

Page 8: ...6 2 Drawings AT S ESF30 SOU5 4 7 2 Drawings AT S ESF30 SOU3 1228 478 295 A A 200 950 139 139 139 139 A A 200 950 139 139 139 139 928 A A A A 1 5 295 478 200 139 139 139 928 A A A A 1 5 295 478 200 139 139 139 139 650 928 A A A A 1 5 295 478 200 139 139 139 1228 478 295 A A 200 950 139 139 139 139 1 Enclosure 2 Switch over modules SOU CG S 2 x 4 A 1 Enclosure 2 Switch over modules SOU CG S 2 x 4 A ...

Page 9: ...1 4 9 1 Components AT S ESF30 SOU1 4 9 2 Drawings AT S ESF30 SOU1 778 A A A A 1 5 295 478 200 139 139 139 500 139 A A A A 1 5 478 200 139 139 139 500 139 628 478 295 A A 139 A 628 478 295 A A 200 350 139 139 139 A A 1 5 139 628 478 295 A A 139 A A 778 A A A A 1 5 295 478 200 139 139 139 500 139 1 Enclosure 2 Switch over modules SOU CG S 2 x 4 A 1 Enclosure 2 Switch over modules SOU CG S 2 x 4 A 1 ...

Page 10: ...k is upon delivery Defects which have arisen due to onward transport of the systems are exclu ded from subsequent fulfilment Transport of the fire protection system to the place of use with a suitable forklift truck on a transport pallet protective corners and strapping Improper transport hard knocks transport without air suspension repeated reloading one sided loading when loading on one side dur...

Page 11: ...ng installations such as gas or water is required In In the vicinity of doors a distance corresponding to the door must be maintained 1 Check the accessories for completeness 6 2 Inserting the cables The cable entry as a system component of the electrical enclosure consists of a a metal cover b the intumescent and endothermic areas The metal cover with different dimensi ons depending on the type o...

Page 12: ...s our highest priority always to find the right solution for every application Our stakeholders therefore expect more than just innovative products Companies turn to Eaton because they know that individual support and the success of our customers is always our top priority For more information visit www eaton com Eaton EMEA Headquarters Route de la Longeraie 7 1110 Morges Switzerland Eaton eu CEAG...

Reviews: