Catalog Number

Output conection

Output cable

5PX1500IRT2UAUG2

(4) IEC10A
(2) IEC10A group 1
(2) IEC10A group 2

(2) IEC10A

5PX2000IRT2UAUG2

5PX2200IRT2UAUG2

(4) (1) IEC16A
(2) (1) IEC16A group 1
(2) IEC10A group 2

5PX2200IRT3UAUG2

5PX3000IRT2UAUG2

5PX3000IRT3UAUG2

8.7  Battery

Internal batteries

Internal batteries

EBM

Specifications

1000VA: 48Vdc - 4 x 12V, 7Ah
1500VA: 48Vdc - 4 x 12V, 9Ah
2000VA: 72Vdc - 6 x 12V, 7Ah
2200VA: 72Vdc - 6 x 12V, 7Ah
3000VA: 72Vdc - 6 x 12V, 9Ah

5PXEBM48RT2UG2: 48Vdc - 2 x 4 x 12V, 9Ah
5PXEBM72RT2UG2: 72Vdc - 2 x 6 x 12V, 9Ah
5PXEBM72RT3UG2: 72Vdc - 2 x 6 x 12V, 9Ah

Type

Sealed, maintenance-free, valve-regulated, lead-acid, with minimum 3-5year float 
service life at 25°C (77°F).

Monitoring

Advanced monitoring for earlier failure detection and warning

EBM battery cable length

400 mm / 15.75 in

8.8  Environmental and safety

Certifications

IEC/EN 62040-1:2008+A1:2013
IEC/EN 62040-2:2017 - Cat. C1
IEC/EN 62040-3
UL1778 5th edition
CSA 22.2

EMC (Emissions)*

CISPR22 Class B
FCC part 15 Class B

EMC (Immunity)

IEC 61000-4-2, (ESD): 8 kV Contact Discharge / 15 kV Air Discharge
IEC 61000-4-3, (Radiated field): 10 V/m
IEC 61000-4-4, (EFT): 4 kV 
IEC 61000-4-5, (Surges): 2 kV Differentiel Mode / 4 kV Common Mode
IEC 61000-4-6, (Electromagnetic field): 10 V
IEC 61000-4-8, (Conducted magnetic field): 30 A/m

Summary of Contents for 5PXEBM48RTG2

Page 1: ...5PX Advanced User Guide Copyright 2021 EATON All rights reserved 614 40099 00 5PX1500IRT2UAUG2 5PX2000IRT2UAUG2 5PX2200IRT3UAUG2 5PX3000IRT2UAUG2 5PX3000IRT3UAUG2 5PXEBM48RTG2 5PXEBM72RTG2 5PXEBM72RT...

Page 2: ...nt a risk of energy or electrical shock or burn from high short circuit current Observe proper precaution Batteries may contain HIGH VOLTAGE and CORROSIVE TOXIC and EXPLOSIVE substances Information ad...

Page 3: ...nit module optional 15 3 6 Connection with a HotSwap MBP module optional 15 4 Interfaces and Communication 16 4 1 Control panel 16 4 2 LCD description 17 4 3 Display functions 18 4 4 User settings 20...

Page 4: ...quipment 33 7 Troubleshooting 33 7 1 Typical alarms and faults 34 7 2 Silencing the alarm 36 7 3 Service and support 36 8 Specification and technical characteristics 36 8 1 Power Module model list 36...

Page 5: ...cy Products are developed according to an eco design approach Substances This product does not contain CFC and HCFC This product does not contain asbestos This product is compliant with regulations on...

Page 6: ...data destroy unsaved work sessions and damage hardware causing hours of lost productivity and expensive repairs With the Eaton 5PX you can safely eliminate the effects of power disturbances and guard...

Page 7: ...2x3 4 603x438x85 5 5PX2200IRT2UAUG2 62 2 28 2 23 7x17 2x3 4 603x438x85 5 5PX2200IRT3UAUG2 60 6 27 5 19x17 2x5 1 483x438x129 5PX3000IRT2UAUG2 69 9 31 7 23 7x17 2x3 4 603x438x85 5 5PX3000IRT3UAUG2 68 6...

Page 8: ...Primary group critical equipment Outlet group programmable outlets USB communication port RS232 communication port Relay output contact Connector for ROO Remote On Off control and RPO Remote Power Of...

Page 9: ...4 DIN HotSwap external maintenance bypass 6 IEC EFLX8F EFLX8D EFLX12I FlexPDU 8 FR FlexPDU 8 DIN FlexPDU 8 IEC 3 Installation 3 1 Inspecting the equipment If any equipment has been damaged during ship...

Page 10: ...ent RS232 communication cable USB communication cable Safety instructions Quick start Cable locking systems Rack kit for 19 inch enclosures Two supports for tower position tower feet Communication car...

Page 11: ...e tower installation with the UPS To install the UPS Place the UPS on a flat stable surface in its final location Always keep 6 or 150 mm of free space behind the UPS rear panel for ventilation If ins...

Page 12: ...614 40099 00 12 Installation in rack position Follow steps 1 to 4 for module mounting on the rails The rails and necessary hardware are supplied by EATON...

Page 13: ...e rail on the back of the rack 2 Fix the rail on the front of the rack using the two holes at the bottom 3 Fix the ears plate to the UPS 4 Place the UPS on the rails and fix the ears plate to the top...

Page 14: ...C power source and the true electrical consumption of the total load 1 For the 5PX 1000 1500 connect the UPS input socket 2 to the AC power source using the cable of the protected equipment For the 5P...

Page 15: ...affecting the connected loads HotSwap function 1 Connect the input socket 48 on the HotSwap MBP module to the AC power source using the cable 13 supplied 2 Connect the UPS input socket 2 to the UPS In...

Page 16: ...e goes ON HotSwap MBP module test 1 Set switch 45 to Bypass position and check that the load is still supplied 2 Set switch 45 back to Normal position 4 Interfaces and Communication 4 1 Control panel...

Page 17: ...fault such as fan blocked or over temperature 4 2 LCD description Load status and measure Equipment status icon Status Message Battery status As default or after 5 minutes of inactivity the LCD displ...

Page 18: ...se the two middle buttons and to scroll through the menu structure Press the Enter button to select an option Press the ESC button to cancel or return to the previous menu Menu map for Display Functio...

Page 19: ...put output signals remote signals IPV4 address Event log Event filter Selects faults alarms and or events to display Event list Displays the events stored Reset event list Clears events Fault log Faul...

Page 20: ...le the buzzer if an alarm occurs Enabled Level 0 8 6 Protected access Enabled Disabled Allow the user to lock the settings modification Password is 0577 Disabled In Out settings Output voltage 200 V 2...

Page 21: ...ult 90 min Enabled 90min Site Wiring Fault Enabled Disabled Prevents from starting the UPS in case of phase vs neutral wires swapping Disabled Power Off alert Yes No If Enabled activates a confirmatio...

Page 22: ...y runtime at the expense of long term battery life warranty is also void if set to disable Enable Comm settings Input signals ROO RPO DB9 4 Sets Input signals parameters function delay operation throu...

Page 23: ...ay 0s 999s Restart Yes No For a proper server shutdown please make sure that the Output OFF delay is long enough Send CMD No Output OFF No OFF delay 0s Restart Yes On battery notice delay 0s 99s Sets...

Page 24: ...8 V DC max Current 25 mA max Power 1 2 W Pin Signal Direction Function 1 Bat low Output Low Battery Output 2 TxD Output Transmit to external device 3 RxD Input Receive from external device 4 I P SIG I...

Page 25: ...tion to the same secure UPS monitoring management and sensor capability as the Gigabit Network card Relay MS card provides isolated dry contact Form C relay outputs for UPS status Utility failure Batt...

Page 26: ...e SELV circuit This circuit must be separated from any hazardous voltage circuits by reinforced insulation The RPO must not be connected to any utility connected circuits Reinforced insulation to the...

Page 27: ...Description On battery On bat DB9 Pin 8 UPS is in battery mode Low battery Low bat DB9 Pin 1 UPS is in battery mode and has reached the low battery alarm threshold Battery fault Batt fault 1 Relay ou...

Page 28: ...alarms and restart if necessary 6 Verify that the indicator illuminates solid indicating that the UPS is operating normally and any loads are powered and protected The UPS should be in Normal mode AC...

Page 29: ...e audible alarm beeps once every 3 seconds This warning is approximate and the actual time to shutdown may vary signifi cantly gracefully shutdown all applications on connected equipment due to immine...

Page 30: ...ure below 10 C 6 2 Storing the equipment If you store the equipment for a long period recharge the battery every 6 months by connecting the UPS to utility power The internal batteries charge to 90 cap...

Page 31: ...tteries replace with the same type and number of batteries or battery packs Contact your service representative to order new batteries Proper disposal of batteries is required Refer to your local code...

Page 32: ...de B Disconnect the battery block by separating the connectors never pull on the wires C Remove the metal protection cover in front of the battery three screws or two screws for 3U models D Pull the p...

Page 33: ...s is required Refer to your local codes for disposal requirements Do not open or mutilate the battery or batteries Released electrolyte is harmful to the skin and eyes It may be toxic Do not discard t...

Page 34: ...nto the Event log Example AC freq in range Alarms are recorded into the Event log and displayed on the LCD status screen with the logo blinking Some alarms may be announced by a beep every 3 seconds E...

Page 35: ...ected If the condition persists contact your service representative The UPS does not provide the expected backup time The batteries need charging or service Apply utility power for 48 hours to charge...

Page 36: ...ontact information If repair is required you will be given a Returned Material Authorization RMA number This number must appear on the outside of the package and on the Bill Of Lading if applicable Us...

Page 37: ...4 22 4 17 6x17 2x3 4 448x438x85 5 5PX2000IRT2UAUG2 61 7 28 0 23 7x17 2x3 4 603x438x85 5 5PX2200IRT2UAUG2 62 2 28 2 23 7x17 2x3 4 603x438x85 5 5PX2200IRT3UAUG2 60 6 27 5 19x17 2x5 1 483x438x129 5PX3000...

Page 38: ...Number Input connection Input cable 5PX1500IRT2UAUG2 IEC C14 10A Not provided 5PX2000IRT2UAUG2 5PX2200IRT2UAUG2 IEC C20 16A Australia 15A 5PX2200IRT3UAUG2 5PX3000IRT2UAUG2 5PX3000IRT3UAUG2 8 5 Electr...

Page 39: ...V 9Ah 5PXEBM72RT3UG2 72Vdc 2 x 6 x 12V 9Ah Type Sealed maintenance free valve regulated lead acid with minimum 3 5year float service life at 25 C 77 F Monitoring Advanced monitoring for earlier failur...

Page 40: ...h the load can be supplied by the UPS operating on battery power EBM Extended Battery Module Low battery warning This is a battery voltage level indicating that battery power is low and that the user...

Reviews: