3.5 Connection with a FlexPDU (Power Distribution Unit) module (optional)
1. 5PX
1000 / 1500 : Use the power cable of the protected
equipment.
5PX
2000 / 2200/ 3000 connect the UPS input socket to
the AC power source using the cable (13) supplied.
2. Connect the input socket on the FlexPDU module (40)
to the UPS outlet (3) using the cable (24) supplied. The
cable and the connectors are marked in red.
3. Connect the equipment to the outlets (41) on the
FlexPDU module. These outlets differ, depending on the
version of the FlexPDU module.
4. Fit the connection securing system that prevents the
plugs from being pulled out accidentally.
3.6 Connection with a HotSwap MBP module (optional)
The HotSwap MBP module makes it possible to service or even replace the UPS without affecting the connected loads
(HotSwap function).
1. Connect the input socket (48) on the HotSwap MBP
module to the AC power source using the cable (13)
supplied.
2. Connect the UPS input socket (2) to the “UPS
Input” (47) on the HotSwap MBP module, using the cable
(26) supplied. These cables and the connectors are
marked blue.
3. Connect the UPS outlet (3) to the “UPS Output” (56)
on the HotSwap MBP module, using the cable (46)
supplied.
These cables and the connectors are marked in
red.
4. Connect the equipment to the outlets (42) on the
HotSwap MBP module.
These outlets differ, depending on the version of
the HotSwap MBP module.
Caution : Do not use UPS outlets (4) to supply
equipment because use of switch (45) on the HotSwap
MBP module would cut supply to the equipment.
HotSwap MBP module operation
The HotSwap MBP module has a rotary switch (45) with
two positions:
Normal
: the load is supplied by the UPS, LED (43) is on.
Bypass
: the load is supplied directly by the AC power
source. LED (44) is on.