IMPORTANT
Verify that the top & lower seals have not extruded into
the ports. If seals have extruded, gently tap bottom of
the seals with the Seal Tool until seals are past the ports.
If not, repeat “Inserting Cartridge ” instructions.
28.
Sizes 1-¼” through 4”
: If cartridge does not lower sufficiently
to tighten the four (4)
cap screws, Item 13
, you will need
to run a washer and nut up the
Extractor Tool
. Insert the
Extractor Tool
through
the bolt hole in cartridge and into
screw threads in strainer body. With washer between nut and
cartridge, tighten the nut that lowers the cartridge into the
body a sufficient distance for the four (4)
cap screws, Item 13
to be tightened.
IMPORTANT
Verify that the top & lower seals have not extruded into
the ports. If seals have extruded, gently tap bottom of
the seals with the Seal Tool until seals are past the ports.
If not, repeat “Inserting Cartridge ” instructions.
29. Tighten
the four (4)
cap screws, Item13
, until the cartridge is
completely
in the strainer body.
For any questions or further assistance,
please call Eaton Technical Support
Cartridge Assembly
IOM53CART Rev.1
June 2010
For more information,
please e-mail us at
or call 732-767-4200.
Visit us online at
for
a complete list of Eaton’s
©2009 Eaton Corporation. All Rights Reserved.
All trademarks and registered trademarks are the
property of their respective owners. Litho USA
Eaton
Singapore
4 Loyang Lane #04-01/02
Singapore 508914
Voice: +65 68251668
Fax: +65 68251639
Eaton
Brazil
Av. Julia Gaioli, 450 –
Bonsucesso
07250-270 – Guarulhos
Brazil
Voice: +55 (11) 6465-8780
Fax: +55 (11) 6480-2808
Eaton
China
NO.3, Lane 280, Linhong Road,
Changning District, 200335,
Shanghai, P.R. China
Voice: 86-21-5200-0099
Fax: 86-21-5200-040
Eaton
North America — HQ
70 Wood Avenue, South
2nd Floor
Iselin, NJ 08830
Toll Free: (800) 656-3344
(North America only)
Voice: (732) 767-4200
Fax: ( 952) 906-3706
Eaton
Europe/Africa/Middle East
Auf der Heide 2
53947 Nettersheim
Germany
Voice: +49-2486-809-0
Fax: +49-2486-809-800
All information and recommendations appearing in this brochure concerning the use of products
described herein are based on tests believed to be reliable. However
, it is the user’s responsibility to
determine the suitability for his own use of such products. Since the actual use by others is beyond
our control, no guarantee, expressed or implied, is made by Eaton as to the effects of such use or the
results to be obtained. Eaton assumes no liability arising out of the use by others of such products. Nor
is the information herein to be construed as absolutely complete, since additional information may be
necessary or desirable when particular or exceptional conditions or circumstances exist or because of
applicable laws or government regulations.
Cartridge Maintenance
Model 53 BTX Duplex Strainer, Sizes
3
⁄
4
” - 4”
8