IOM53CART Rev.1  June 2010                                                                   Filtration.Eaton.com  

Ensure that the 

middle stem, Item 26

 is equally spaced between 

upper and lower ball bores of the cartridge. 

Ensure that both 

middle stem O-rings, Item 20

 are compressed 

into the cartridge middle stem bore.

Align flat tabs of the 

middle stem, Item 26

 to be inline to the large 

ports of the cartridge. This allows the flats of the 

middle stem, 

Item 26

 to be aligned with the slots of the 

balls, Item 24

.

15.  Lubricate the 

top stem O-rings, Item 20

 and inside of the 

cartridge top stem bore. Insert 

top stem, Item 25

 into top of 

cartridge. Push down until shoulder on tab end of 

top stem, 

Item 25

 is flush with inside of the large ports of the cartridge 

(cartridge ball bore).

16.  Align flat tab on 

top stem, Item 25

 to be in-line to the large 

ports of the cartridge. 

Top stem

 tabs and 

middle stem

 tabs 

are to be in the same direction. Remove handle from 

top 

stem

.

17.  Place 

stem retainer washer, Item 19

, then 

stem retainer, 

Item 11

 over 

top stem, Item 25

. Centralize the hole of 

the 

stem retainer, Item 11

 around the 

top stem, Item 25

The two (2) small locating posts under 

stem retainer

 point 

towards the inlet on the cartridge. Insert and tighten the two 

(2) 

screws, Items 12 & 14

.

18.  Attach 

handle, Item 17 

to 

top stem, Item 25

 using 

screw, 

Item 18 

(and washer if provided). Move handle counter-

clockwise until contact is made with the stem retainer.

19.  Lay cartridge down on table with top of cartridge away 

from assembler and inlet facing up and the 

handle, Item 17 

pointing to your right.

20.  Insert 

upper ball, Item 24 

keeping closed side of ball opposite 

the

 handle, Item 17

 (see View “B-B”). Assemble two (2) sets 

of 

seals Item 22

 and 

seats, Item 23

. Match the recess groove 

in the 

seat 

to raised channel in the 

seal.

 Slide the 

seat and 

seal 

assemblies into the cartridge around the 

upper ball, 

Item 24

 keeping the recess groove in the 

seat 

and the raised 

channel in the

 seal

 to top of cartridge. 

Wrap securely about 

the center with wire tie provided.

21.  Insert 

lower ball, Item 24

 keeping closed side of ball opposite 

the 

handle, Item 17

 (see View B-B). Assemble two (2) sets of 

seals Item 22 and seats Item 23.

 Match the recess groove 

in the 

seat

 to raised rib on the 

seal

. Slide the 

seat and seal 

assemblies into the cartridge around the 

lower ball, Item 24 

keeping the recess groove in the 

seat

 and the raised channel 

in the 

seal

 to top of cartridge. 

Wrap securely about the 

center with wire tie provided.

22.  Stand the cartridge up with top up and inlet facing assembler. 

Check for alignment.

IMPORTANT 

Inside diameters of balls are to be aligned 

with inside diameter of seats.

23.  Lubricate the outer face of each of the 

seals

, cartridge 

O-rings 

and inside of cartridge bore in the body with a light 

film of Process Compatible lubricant. 

INSERTING CARTRIDGE

When inserting the cartridge into the strainer body: 

Sizes ¾” through 1”

: Make sure that the flow arrow on the 

cartridge is pointing 45 degrees to either side of the outlet 

on the body. 

 

Sizes 1-¼” through 4”:

 Make sure that the 

word “INLET” on the top of the cartridge is 

directly above the inlet of the body.

24.  Lift cartridge and place inside the cartridge bore of the body. 

Carefully

 

start (or lead) the

 

lower seals, Item 22 into the 

cartridge bore of the body.

 Remove wire tie around the lower 

seals when 

lower seals, Item 22

 have been lowered halfway 

into cartridge bore of the body. 

Sizes 1-¼” through 4”

: Make sure that the lower 

seals, Item 22

 smoothly pass through all of the internal 

openings (or ports). If the lower 

seals

 start to extrude 

into ports, gently tap bottom of the 

seals

 with the 

Seal 

Tool

 (provided). Thus greatly assisting the leading edges 

of the 

lower seals 

into cartridge bore of the body

25.  Push cartridge down until half of the 

top seals, Item 22

 are in 

the cartridge bore of the body. Use the 

Seal Tool

 (provided) 

as required. Follow same instructions for the 

upper seals

 as 

described in #24 above for the 

lower seals

.

26. 

Remove wire tie around the top seals at this time

27. 

Sizes ¾” through 1”

: Push cartridge down until just above roll 

pin in body. Turn cartridge 45 degrees, so that the flow arrow 

(cast on the top of the cartridge) is aligned with the outlet of 

the strainer. Insert the four (4) 

cap screws, Item 13

 and turn 

until cartridge is all the way into body.

Cartridge Maintenance

Model 53 BTX Duplex Strainer, Sizes 

3

4

” - 4”