9. Introduction – 6000H(XL)/ 10000H(XL) 

 

9.1 Product Specification and Performance 

 

1) General Specification

 

Model 6000H 

6000HXL 

10000H 

10000HXL 

Power Rating 

6KVA/4.2KW 

6KVA/4.2KW 

10KVA/7KW 

10KVA/7KW 

Frequency (Hz) 

50 

50 

50 

50 

Voltage 

(176-276)VAC (176-276)VAC (176-276)VAC (176-276)VAC 

Input 

Current 

31A max. 

31A max. 

50A max 

50A max. 

Voltage 240VDC 

240VDC 

240VDC 

240VDC 

Battery 

Current 

24A max 

24A max 

40A max 

40A max 

Voltage 220VAC 

220VAC 

220VAC 

220VAC 

Output 

Current  27A 27A 45A 45A 

Dimension (WxDxH) mm 

260x570x717 260x570x717 260x570x717 260x570x717 

Weight (kg) 

90 

35 

93 

38 

 

2) Electrical Performance 

Input 

Model Voltage 

Frequency 

Power 

Factor 

6000H(XL)/10000 H(XL)  Single-phase 

46Hz-54Hz 

>0.98 (Full load) 

 

Output 

Voltage 

Regulation 

Power 
Factor 

Frequency 

tolerance. 

Distortion

Overload capacity 

Current crest 

ratio 

±

1% 

0.7 lag 

Synchronized 

46-54Hz in 

Line mode 

(AC mode) 

±

0.1% of 

normal 

frequency in 

Battery mode

THD<2% 

Full load 

(Linear 

Load) 

105%-130% load 

transfers to bypass 

mode after 10 minutes

>130% load transfers 

to bypass mode after 1 

second and shutdown 

the output after 1 

minute 

3:1 

maximum 

 

3) Operating Environment 

Temperature Humidity 

Altitude Storage 

temperature

0

°

C-40

°

<95% <1000m 0

°

C-40

°

 

 

Note: if the UPS is installed or used in a place where the altitude is above than 

1000m, the output power must be derated in use, please refer to the following: 

Altitude 

(M) 

1000 1500

2000

2500

3000

3500 4000 4500

5000

Derating 

Power 

100% 95%

91%

86%

82%

78% 74% 70%

67%

Summary of Contents for 1000H(XL)

Page 1: ...24 www eaton com dxups USER MANUAL ON LINE UPS 1000H XL 2000H XL 3000H XL 6000H XL 10000H XL Uninterruptible Power Supply...

Page 2: ...a 13 14 8 1 Electrical Specifications 13 8 2 Operating Environment 13 8 3 Typical Stored Energy Time Typical values at 25 C in minutes 13 8 4 Dimensions and Weights 14 9 Introduction 6000H XL 10000H X...

Page 3: ...all Models 28 29 16 Communication Port 30 17 Software for all models 31 18 Appendix 32 36 Appendix1 Display Panel for 6000H XL 10000H XL 32 Appendix2 The Corresponding Form of the LED Display for 6000...

Page 4: ...block ventilation openings in the UPS s housing Do not connect appliances or items of equipment which would overload the UPS e g laser printers etc to the UPS outlet sockets Place cables in such a way...

Page 5: ...f socket during operation as this would remove the ground to the UPS and of all connected loads The UPS output socket or output terminal block may be electrically lived even if the UPS system is not c...

Page 6: ...y be toxic Please replace the fuse only by a fuse of the same type and of the same amperage in order to avoid fire hazards Do not dismantle the UPS except the qualified maintenance personnel 1 Safety...

Page 7: ...evel 4 SURGE IEC EN 61000 4 5 Level 4 Low Frequency Signals IEC EN 61000 2 2 Warning This is a product for restricted sales distribution to informed partners Installation restrictions or additional me...

Page 8: ...e batteries and powers the inverter On the basis of this DC voltage the inverter generates a sinusoidal AC voltage which permanently supplies the loads Computers and periphery are thus powered entirel...

Page 9: ...lerance BATTERY LED The orange coloured BATTERY LED lights up when the mains power has failed and the inverter is being powered by the batteries BYPASS LED The orange coloured BYPASS LED lights up whe...

Page 10: ...put of 1000H XL and 2000HXL Non CE are socket types only Simply plug the load power cord to the output sockets to complete connection Model No Output Socket pcs Terminal Block 1000H XL 4 Nil 2000H 6 N...

Page 11: ...at this time the Utility Power LED Inverter LED and Load and Battery Capacity LEDs will light up 4 2 Without utility power connecting Even though utility power is connected to the UPS the UPS still ca...

Page 12: ...required will cause abnormality 2 One end of the external battery cord is a plug for connecting the UPS and the other end has a plug for connecting the user battery cabinet 3 Do not connect the UPS t...

Page 13: ...of the UPS to supply utility power to the UPS to make the UPS operation in utility power mode 8 Plug the external battery cord to the external battery socket on the rear panel of the UPS to complete t...

Page 14: ...Switch I INVERTER LED lights up and audible alarm sounding every 1 beep in every 4 seconds Mains power supply has failed Switching to battery mode automatically When audible alarm sounding every seco...

Page 15: ...ient temperature has been exceeded the batteries must be replaced In this case please contact your dealer 7 2 Storage If the batteries are stored in temperate climatic zones they should be charged eve...

Page 16: ...2 1kW Voltage 220 230 240 1 2 VAC Frequency 50Hz 0 2Hz Battery mode Wave form sinusoidal BATTERIES Model No 1000H 2000H 3000H Number and type 3 12V 7 2Ah 8 12V 7 2Ah 8 12V 7 2Ah 8 2 Operating Environm...

Page 17: ...Data 8 4 Dimensions and weights Model No Dimensions W x D x H mm Net Weight kg 1000H 145X400X220 14 1000HXL 145X400X220 7 2000H 192X460X340 34 5 2000HXL 192X460X340 15 3000H 192X460X340 35 5 3000HXL 1...

Page 18: ...cy Power Factor 6000H XL 10000 H XL Single phase 46Hz 54Hz 0 98 Full load Output Voltage Regulation Power Factor Frequency tolerance Distortion Overload capacity Current crest ratio 1 0 7 lag Synchron...

Page 19: ...ay occur if the UPS is unpacked in a very low temperature environment In this case it is necessary to wait until the UPS is fully dried inside out before proceeding installation and use Otherwise ther...

Page 20: ...output power distribution panel of the UPS if necessary 8 To connect the load with the UPS please turn off all the loads first then perform the connection and finally turn on the loads one by one 9 N...

Page 21: ...ied in the general specification 2 Set the battery pack breaker in OFF position and connect the 20 pieces of batteries in series 3 You must connect the external battery cable to the battery first if y...

Page 22: ...ich should have 25 cores corresponding stitches and shield as the UPS parallel cable The length of the parallel cable is appropriate to be less than 3 m 2 Strictly follow the stand alone wiring requir...

Page 23: ...S with utility power supplied in Line mode AC mode 1 After you make sure that the power supply connection is correct set the bypass breaker and the input breaker in the ON position first At this time...

Page 24: ...self diagnosis finally not any display is shown on the display panel and no voltage output is available from the UPS output 4 Turn off the UPS with no utility power supplied in Battery mode 1 Press t...

Page 25: ...d output live wire of parallel system If the voltage difference 1V please close output live wire s witch of new UPS 7 Take apart the board of parallel ports when UPS has turned to bypass mode insert t...

Page 26: ...arallel cover and combine line connected with the UPS which need to remove until all UPS panels become black then lock up the cover of parallel ports again 6 Take apart UPS parallel cover and combine...

Page 27: ...g backup time model is dependent on the external battery pack capacity and the load level as well as other factors The backup time of standard model may vary from different models and load level Pleas...

Page 28: ...egions of hot climates the battery should be charged and discharged every 2 months The standard charging time should be at least 12 hours Under normal conditions the battery life lasts 3 to 5 years In...

Page 29: ...de otherwise it may result in electric shock or fire 6 Make sure that there is no voltage before touching the batteries The battery circuit is not isolated from the input potential circuit There may b...

Page 30: ...ment is faulty Check the loads and remove all no critical equipment Recalculate the load power and reduce the number of loads connected to the UPS Check that the loads are not failed The 1 Fault LED i...

Page 31: ...ation is stable before supplying power of the generator to the UPS be sure that the UPS is in idle mode Then turn on the UPS according to the start up procedure After the UPS is turned on then the loa...

Page 32: ...power LED and the bypass LED are lit The displayed number of the load LEDs will be turned on in accordance with the load capacity connected The UPS will beep once every 2 minutes in bypass mode The ut...

Page 33: ...s series UPS has AS400 card an optional accessory for AS400 communication protocol Please contact your local distributor for details The following is the pin assignment and description of DB 9 connect...

Page 34: ...ontrol any UPS on the same LAN no matter how far from the UPSs Installation procedure 1 Go to the website http www ups software download com winpower htm 2 Choose the operation system you need and fol...

Page 35: ...lity power LED is turned on it shows that the utility power is normal Inv LED green LED Whenever the INV LED is turned on it shows that the loading current is supplied from utility power or battery vi...

Page 36: ...overloaded in utility mode and UPS still in INV mode Beep twice every sec 13 overloaded in utility mode and UPS in bypass mode Beep twice every sec 14 Utility power abnormal 15 Overloaded in battery m...

Page 37: ...nd output socket are vary with different areas the appearance of the products is based on what it is Back View of 1000H XL Figure 1 Back View of 1K 1KS Back View of 2000H XL Non CE certified 2000H CE...

Page 38: ...Back View of 3000H XL Non CE certified Back View of 3000H XL CE certified Back view of 6000H Back view of 6000HXL For XL Model only...

Page 39: ...Back view of 10000H Back view of 10000HXL...

Page 40: ...614 03754 01...

Reviews: