Operating Instructions
Be sure all operators and others around the compressor and its controls comply with all applicable OSHA, Federal,
State and Local regulations, codes and standards relating to personal protective equipment. This includes respiratory
protective equipment, protection for the extremities, protective clothing, protective shields and barriers, electrical
protective equipment, and personal hearing protective equipment.
2.
DO NOT
use air line anti-icer systems in air lines supplying respirators or other equipment used to produce
breathable air.
DO NOT
discharge air from these systems in unventilated or other confined areas.
1.
Install compressor pump in a clean, dry and well-lit area. Be sure installation area can maintain a
temperature range between 35˚ - 110˚ F.
2. Insulate cold water or other low temperature pipes that pass overhead to avoid condensation dripping on
compressor which could cause rust and/or motor shorting.
Inspect compressor pump prior to any use. Check for external damage that
might have occurred during transit. Be careful of moving parts then test
pulley by turning it freely by hand.
Report any damage to delivery carrier
immediately.
WARNING
Do not operate unit if damaged during shipping, handling or use.
Damage may result in bursting and cause injury or property damage.
WARNING
DO NOT install compressor in boiler room, paint spray room, or area
where sandblasting occurs. Make sure inlet air is away from exhaust
fumes or other toxic, noxious or corrosive fumes or substances.
DANGER
Personal Protective Equipment
Inspection
Installation
Area
4
Summary of Contents for POLAR AIR P01PSXXP10V120V208X
Page 1: ...Polar Air Electric Operated Piston Compressors 1...
Page 32: ......
Page 39: ......
Page 40: ......