background image

2

Toxin    |    Installation & Service Manual

Unpacking & Inspection

Basic Guidelines

Be sure to inspect the entire shipment immediately upon receipt for any shipping damage or parts 
loss.  Also note any damage to the shipping carton.  

Contact the transportation company for all 

damages and loss claims.  EasyWater is not responsible for damages in transit.

 

»

Before you begin installation, read the entire manual. 

 

»

CHECK LOCAL PLUMBING AND ELECTRICAL CODES. THE INSTALLATION MUST 
CONFORM TO STATED CODES.

  

 

»

Use only lead-free solder and flux for all sweat-solder connections, as required by state and 
federal codes.

 

»

Use care when handling the filter.  Do not drop or set on sharp objects.

 

»

Do not locate the system where freezing temperatures occur.  Do not attempt to treat water that 
is over 120°F.  

FREEZE DAMAGE OR HOT WATER DAMAGE VOIDS THE WARRANTY.

 

»

If installing outdoors, protect from direct sunlight.  Excessive sun and heat may cause distortion 
or other damage to non-metallic parts.

 

»

While the electronic components, protect the filter if installing it outdoors where water damage 
can occur.

 

»

Unplug the filter from electrical power before servicing the filter or removing the outer valve 
cover.  Complete maintenance or repairs and replace covers before plugging into the power 
outlet again.

 

»

The filter works on 120V – 60 Hz electrical power only.  

MAKE SURE THE FILTER IS PLUGGED 

INTO AN OUTLET WITH CONTINUOUS POWER.

Summary of Contents for Toxin Shield+ TS+1000

Page 1: ...Installation Service Manual ...

Page 2: ...on Where to install the filter 4 Tools pipe fittings other materials needed 4 Plan how you will install the filter 5 Product Installation Sequence 5 Installing Valve Head on Tank 5 Setting the Controller 6 7 System Start Up 8 Troubleshooting 9 Limited Warranty 10 Toxin Shield Installation Service Manual ...

Page 3: ...es Use care when handling the filter Do not drop or set on sharp objects Do not locate the system where freezing temperatures occur Do not attempt to treat water that is over 120 F FREEZE DAMAGE OR HOT WATER DAMAGE VOIDS THE WARRANTY If installing outdoors protect from direct sunlight Excessive sun and heat may cause distortion or other damage to non metallic parts While the electronic components ...

Page 4: ... gpm 12 gpm Max Service Flow Rate 20 gpm 20 gpm Min Backwash Flow Rate 5 gpm 10 gpm Max Pressure 120 psi 120 psi Tank Size 10 x 54 13 x 54 A B C Depth All10 Diameter Filters 11 57 64 5 16 All13 Diameter Filters 14 57 64 5 16 All16 Diameter Filters 16 65 72 5 16 INLET OUTLET OUT INLET C B A 2 6 5 7 5 ...

Page 5: ...e it could freeze Freeze damage is not covered by the warranty A 120 volt electric outlet is required to plug in the filter controller The filter comes with a 24 volt transformer with a 10 foot power cord This connection must meet local electrical codes Keep the filter out of direct sunlight as excessive sun and heat can distort any not metallic parts TOOLS PIPE FITTINGS OTHER MATERIALS NEEDED A m...

Page 6: ...to the tank ensuring the threads are not cross threaded Note All Fleck valves are right hand threads or clockwise to install 2 Rotate the valve freely without using force until it comes to a stop this position is considered zero 3 Rotate valve clockwise from zero to between turn and turn see diagram to the right Turn Tank Valve Turn Zero Turn Good Zone Rotation Turn Zero INSTALLING VALVE HEAD ON T...

Page 7: ...n cycle is approximately 16 minutes 1 Backwash 15 minutes Water flow is reversed inside the unit to lift the filter media rinsing contaminants and sediment from the filter bed 2 Fast Rinse 1 minute This packs the bed readying the system to begin filtering water again 3 The system then returns to the Service position Untreated water is available during the regeneration cycle It is important that no...

Page 8: ...ill give your filter full capacity should you expect much higher than normal water usage tomorrow a Press the REGEN button b The words Regen Today will flash on the display to indicate that the system will regenerate tonight at the normal set time typically 12 30am SCHEDULING A REGENERATION IMMEDIATELY Water conditions fluctuate as does water usage If you begin getting iron or manganese staining o...

Page 9: ... the water service valve SLOWLY 4 Close the two open faucets inside the home 5 Check installation for leaks 6 Backwash the unit until water runs clear 7 Press and Hold the REGEN button for 5 seconds to initiate an immediate regeneration 8 Let homeowner know the system will be regenerating for the next 16 minutes During this time they will have water to the home but it will be untreated until regen...

Page 10: ... at same time as another system Solution Ensure unit is plugged in and receiving power Ensure system is not on a switch that gets turned off Reset time of day and check settings Replace motor Ensure drain line is as straight as possible without any kinks Check drain fitting drain line and clear any obstructions Increase backwash frequency Ensure tube is not cracked or broken Ensure O ring where tu...

Page 11: ...rges will apply We assume no warranty liability in connection with this Filter other than specified herein This warranty is in lieu of all other warranties express or implied including warranties of fitness for a particular purpose We do not authorize any person or representative to assume for us any other obligations on the sale of this filter Should a defect or malfunction occur contact your Eas...

Reviews: