Commonly use simple judgment method of platform standard distance: put a
sheet of paper between the nozzle and platform, and pull it out, the paper with
a scratch but no broken means the distance is proper.
If the distance between the nozzle and the platform is too far, turn the screw
nut counterclockwise to raise the printing platform to the standard distance.
If the distance between the nozzle and the printing platform is too close, turn
the srew nut clockwise to reduce the printing platform to the standard distance.
Adjust the remaining "second point", "third point" and "fourth point" according
to the method of "first point". When the distance between the nozzle and the
printing platform is a sheet of paper thickness standard, the printing platform is
leveled
Note: If in the adjustment process, the screw has been set to the limit, indicating that
the entire height of the platform needs to be adjusted, adjust the height of the
platform and limit switch, and then adjust four points.
After Leveling, you can more the print head from one conner to another conner , to
check if the distance between the nozzle and platform is proper.