background image

5 STEP INSTALLATION 

EasyShed

(Two persons required to handle and fasten panels together) 

Step 

1.  Layout the four wall panels as shown with the ribs facing down. 

Step 2. 

Raise the two panels together as shown. The side 

panel will rest in the cut-out section of the front and rear 

U channels. Working from outside the shed, fasten the 

WARNING! 

DO NOT ATTEMPT TO CONSTRUCT 

THE SHED DURING WINDY 

CONDITIONS. SUDDEN WIND GUSTS 

MAY DAMAGE THE PANELS OR 

CAUSE PERSONAL INJURY. 

screws through the corner rib overlap.------------

Alternatively, pre-drill 3mm holes for the screws or use 

3mm pop rivets if desired. Working from top to bottom, 

fasten the corner rib overlap 30mm from the top & 

bottom, then equally space three more screws about 

440mm apart. 

MODEL: EF-D3008 

CORNER 

RIB 

OVERLAP 

Page 18 

Summary of Contents for EF-D3008

Page 1: ...fasyShed 5 Step Assembly SEP 2021 MODEL EF 03008 Flat Roof Model EF D3008 Size 3 0m x 0 78m x 1 82m E E 0 N 00 Page 1 ...

Page 2: ...ROW 710mm w SN1 240 SELF DRILLING SCREW ESCREW12 40 POP RIVET ERIVET S 6 INTERNAL CHANNEL JOINER EICJ 4 BUTT HINGE HINGE64 1 DOOR PLATE EDP 3 PADBOLT HASP EPAH NOTE Where possible most components have been marked with Part Numbers for easy identification Other components not able to be marked can be easily identified by their description sketches and sizes shown on the Pack List and throughout thi...

Page 3: ... QTY DESCRIPTION PART DETAIL IMAGE 2 970mm L FLASHING L970 2 1800mm JAMB J1800 1 1740mm JAMB J1740 4 1125mm JAMB J1125 3 1740mm U CHANNEL C1740 2 1575mm U CHANNEL C1575 4 1500mm U CHANNEL C1500 4 780mm U CHANNEL C780 4 777mm U CHANNEL C777 8 1500mm U CHANNEL CUT OUT ONE END C1500N1 ...

Page 4: ...debris Unpack the cartons check off and familiarise yourself with all the components against the check lists Separate sort and identify the various components Two people are recommended when handling the completed roof wall panels Always carry the panels vertically with one person at each end Do not attempt to handle the panels during windy conditions Sudden wind gusts may damage the panels or cau...

Page 5: ...EasyShed L970 ClS00Nl ClSOONl 80 ClS00Nl J1125 C1740H C777 J1125 l C1740H EXPLODED VIEW OF ALL COMPONENTS C1740 C777 C777 J1740J MODEL EF D3008 ...

Page 6: ......

Page 7: ...revent water entry under the walls of the shed DIAGONAL MEASUREMENTS MUST BE EQUAL PERIMETER BOXING ANCHOR SET 50 X 25 REBATE BOXING E E o 0 LF7 MESH WITH 30mm TOP COVER METHOD C c Cs Drive galvanized anchor pegs into the ground with the hook fastened over the bottom channel for short term temporary anchoring WALL DRILL A 10mm HOLE THROUGH THE WALL PANEL AND SECURE NUT BOLT Using a 10mm diameter m...

Page 8: ......

Page 9: ......

Page 10: ......

Page 11: ...ends butted together to form lengths of 3000mm then join the U channels together with the channel joiners EICJ Fasten the channel joiners and the U channels to the sheet in one operation as shown MODEL EF D3008 3 3 Position and fasten the two L flashings The L flashing fits between the U channel and the outside face of the sheet EasyShed L970 __ SAFETY EDGE _J Page 11 ...

Page 12: ...les into the channel then fasten with two rivets as shown Isa JIr x fJ Once the hinges are fitted to the door channel the door channel part number HINGE PIN THIS SIDE l E will have the letter H added to it as shown below C1740 C1740H This will make it easier to identify the hinged door channel in following door assembly steps 4 2 Repeat Step 4 1 for a second C1740 channel MODEL EF D3008 PAGE 12 LO...

Page 13: ...annels into position and secure with just two screws each at this stage Ensure the U channels are flush with the edges of the sheet 4 5 Move the jamb J1740 and the U channel C1740H into position Ensure the jamb and U channel are butted up firmly to the edges of the sheet following the vertical sheet rib lines Fasten with just one screw at each corner of the sheet at this stage Jl lf 740 JAMB ONLY ...

Page 14: ... two C777 U channels into position and secure with just two screws each at this stage Ensure the U channels are flush with the edges of the sheet 4 10 Position the door plate exactly half way up the door The flat end of the door plate is fitted fitted between the U channel and the door sheet After drilling 3mm holes at rivet locations fasten the door plate to the sheet rib with two rivets then fas...

Page 15: ...Page 15 ...

Page 16: ... 4 Double check that the door opening is correct by laying the door in position The width of the door opening must be exactly the same from top to bottom Continue fastening the remainder of the panel together as shown below 0 MODEL EF D3008 Page 16 ...

Page 17: ...5 diagonally to the inside face of the door Fasten through the door brace into the sheet remove the screws and re fasten the screws from the outside face of the door MODEL EF D3008 Page 17 Each end of the door brace should tuck under the door U channels and meet neatly at the centre of the door as shown 5 5 Turn each door over so they rest upside down on top of the front panel Secure the hinges to...

Page 18: ...annels Working from outside the shed fasten the WARNING DO NOT ATTEMPT TO CONSTRUCT THE SHED DURING WINDY CONDITIONS SUDDEN WIND GUSTS MAY DAMAGE THE PANELS OR CAUSE PERSONAL INJURY screws through the corner rib overlap Alternatively pre drill 3mm holes for the screws or use 3mm pop rivets if desired Working from top to bottom fasten the corner rib overlap 30mm from the top bottom then equally spa...

Page 19: ...N HOLE As the roof is perfectly flat water may become entrapped on the roof during heavy rainfall and may seep between sheet laps and drip into the shed If this is of concern add extra screws and a bead of silicone to seal the joint and drill small holes in the perimeter channels to allow the water to escape Step 5 Secure the shed to the concrete in accordance with the recommendations on page 8 If...

Page 20: ...ducts can also rapidly corrode the garden shed components Durabuilt accepts no responsibility for damage to the garden shed or contents arising from any of the above recommendations and maintenance guidelines GUARANTEEDFORQUALITY EasySHED are manufactured for quality and strength and warranted for a period of up to 20 years from date of purchase Retain your proof of purchase to effect your warrant...

Page 21: ......

Page 22: ......

Page 23: ...MODEL EF D3008 FACTORY CHECK LIST CUSTOMER SEE OTHER SIDE FLAT ROOF MODEL EF D3008 Sheeting Box 1 of 1 Box 1 of 1 Base 2160 x 67 SHEETING 6 1800mm WALL SWR1 2 1740mm DOOR SD1 4 970mm ROOF SR3 2 1800mm NARROW SN1 ...

Page 24: ...EL EF D3008 Sheeting Box 1 of 1 Box 1 of 1 Base 2160 x 67 NARROW SHEETS 2 1800mm LONG 710mm WIDE SN1 JAMBS 2 1800mm J1800 1 1740mm J1740 4 1125mm J1125 L FLASHINGS 2 970mm L970 HARDWARE PACKS 1 HARDWARE PACK EHP 3 v3 1 HARDWARE PACK EHP HINGE 4 INNER CHANNEL KIT 1 INNER CHANNEL KIT ...

Reviews: