EasyPro ECF10 Instructions For Operation Manual Download Page 5

Figure 16

Figure 15

Figure 14

Figure 13

8.   Gently pull straight up on the threaded connection in the 

middle and remove the UV housing. (see figure 11)

9.   Be sure to pull straight up. Do not bend sideways as the UV 

sleeve is glass and can break.  

10.  Carefully remove the glass sleeve by pulling straight down. 

Glass is very fragile, use caution when removing and han-

dling broken glass. Clean the glass sleeve with a clean 

damp cloth. (see figure 12)

11.  Reinstall the black end piece on the end of the sleeve and 

carefully slide the UV cover back into place. 

12.  The UV sleeve will slide around a black ring and will only go 

in about 

1

/

2

".

13.  Carefully place the UV housing and bulb back into the filter. 

(see figures 11 & 10)

14.  Reattach the cord retainer clip with the two screws. (see 

figure 5)

15.  Make sure to line up the power cord in the back with the slot 

in the UV cover. (see figures 3 & 9)

16.  Install the UV light cover and 

screw down the retaining ring. 

(see figure 1)

17.  Reattach the barbed fittings to 

the pressure filter.

Pressure Filter Cleaning

1.   There is a cleaning indicator on 

the top of the filter. It will be green 

in normal operation. When the fil-

ter needs to be cleaned the indi-

cator will turn to red. (see figures 

14 & 15)

2.   When this occurs, if the pressure filter is equipped with UV, 

disconnect the pump from the power source.

3.    If the filter is a pressurized unit, the pressure must be re-

leased before removing the lid. This 

can be done by disconnecting the 

inlet and outlet hoses.

4.   If your unit is an ECF10 or ECF10U, 

you will need to undo the four retain-

ing clips. If your filter is an ECF25 

(U) or ECF40 (U), you will need to 

release the tension ring. (see figures 

16, 17 & 18)

5

Figure 12

Summary of Contents for ECF10

Page 1: ...er then passes through the plastic biomedia where more beneficial bacteria cleans the pollutants The UV light is then used on the passing water to kill free floating algae cells which cause green water As the foam layers in the pressure filter collect solids the cleaning indicator on the lid will rise up This signals that the foam layers need cleaning These filters take in dirty water from the pum...

Page 2: ...l shock fire hazard personal injury or death damaged equipment provide unsatisfactory performance and may void manufacturer s warranty Installation of the Pressure Filter 1 The ECF10U ECF25U and the ECF40U come with the UV light already installed 2 Position pump at the furthest point from the waterfall Run the tubing out of the pond and bury or conceal the tubing 3 It is recommended that the pump ...

Page 3: ...move the retaining ring Twist the UV housing and match the arrow on the UV cover with the arrow on the retaining ring Gently pull up on the cord and cover in the back to loosen the UV cover see figure 1 and 9 4 Loosen and remove the three screws on top of the UV cover see figure 2 5 Remove the UV cover and set aside see figures 3 4 6 Remove the two screws and the plastic retainer clip that hold th...

Page 4: ...slot in the UV cover Be sure to line up the two slots in the front of the UV cover with the two prongs behind the discharge connection Push down on the UV cover and line up the arrow on the UV cover with the arrow on the retaining ring see figure 9 16 Twist the UV housing back to desired position and tighten the screws down on the retaining ring UV Sleeve Replacement and Cleaning 1 Make sure the u...

Page 5: ...r clip with the two screws see figure 5 15 Make sure to line up the power cord in the back with the slot in the UV cover see figures 3 9 16 Install the UV light cover and screw down the retaining ring see figure 1 17 Reattach the barbed fittings to the pressure filter Pressure Filter Cleaning 1 There is a cleaning indicator on the top of the filter It will be green in normal operation When the fil...

Page 6: ...our pressure filter 9 If there is excess build up in the bottom of the pres sure filter you can rinse it out but do not clean 100 This is where the beneficial bacteria grow see figure 21 10 Replace the filter pads and install the lid assembly and clamp down with retaining clips or tension ring see figures 16 18 11 If for some reason the large o ring comes off it is best to put it back on the lid a...

Page 7: ...4 1 3 4 1 11 4 11 2 11 4 11 2 11 4 11 2 11 4 11 2 Recommended maximum GPH 600 600 1350 1350 2000 2000 Replacement Filter Part ECF10F ECF10F ECF25F ECF25F ECF25F ECF25F UV Bulb Part None 10UB None 25UB None 40UB UV Sleeve Part None 10US None 25US None 40US Inlet Outlet Hose Barb Part BARB1 BARB1 BARB2 BARB2 BARB2 BARB2 Fish load amount of sunlight etc all affect actual maximum gallons filtered 7 ...

Page 8: ... to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt name return address and phone number inside of the pack age No warranty claims will be honored without the original receipt Ensure the product is properly packaged and insured for the replacement value Damage due to im proper packaging is the responsibility of the sender...