8.   Use a clean cloth to 

remove the UV light by 

gently pulling up on the 

UV bulb. (see figure 7)

9.  Do not touch the bulb 

with your fingers.  

10.  Carefully remove the 

black protector on the 

end of the bulb. Install 

the black protector on 

the end of the new UV 

light bulb. (see figure 8) 

11.  Carefully install the new 

UV bulb in the base, be sure to use a clean cloth to install 

the new bulb. Press the bulb firmly into the base until you 

here a click. (see figure 7)

12.  Carefully slide the new bulb into the sleeve and screw the 

cap into place.

13.  Reattach the cord retainer clip with the two screws.
14.  If you have an ECF25U or an ECF40U set the UV cover 

back on top of the pressure filter and tighten the three 

screws.

15.  If you have an ECF10U make sure to line up the power 

cord in the back with the slot in the UV cover. Be sure to 

line up the two slots in the front of the UV cover with the 

two prongs behind the discharge connection. Push down 

on the UV cover and line up the arrow on the UV cover with 

the arrow on the retaining ring. (see figure 9)

16.  Twist the UV housing back to desired position and tighten 

the screws down on the retaining ring.

UV Sleeve Replacement and Cleaning

1.   Make sure the unit is disconnected from the power source.  
2.   Unscrew the barbed fittings from the inlet and outlet on the 

filter.  

3.   Loosen the screws on the top retaining ring. Remove the 

screws. The retaining ring should now be loose. (see figure 

1)

4.   Remove the UV cover and set aside. (see figure 3)
5.   Remove the two screws and the plastic retainer clip that 

hold the cord in place and set aside. (see figure 5)

6.   Unscrew the UV light and carefully remove from the hous-

ing. (see figure 10)

7.   Carefully set the UV bulb aside, being careful not to touch 

the UV bulb. 

Figure 9

Figure 10

Figure 11

4

Figure 7

Figure 8

Summary of Contents for ECF10

Page 1: ...er then passes through the plastic biomedia where more beneficial bacteria cleans the pollutants The UV light is then used on the passing water to kill free floating algae cells which cause green water As the foam layers in the pressure filter collect solids the cleaning indicator on the lid will rise up This signals that the foam layers need cleaning These filters take in dirty water from the pum...

Page 2: ...l shock fire hazard personal injury or death damaged equipment provide unsatisfactory performance and may void manufacturer s warranty Installation of the Pressure Filter 1 The ECF10U ECF25U and the ECF40U come with the UV light already installed 2 Position pump at the furthest point from the waterfall Run the tubing out of the pond and bury or conceal the tubing 3 It is recommended that the pump ...

Page 3: ...move the retaining ring Twist the UV housing and match the arrow on the UV cover with the arrow on the retaining ring Gently pull up on the cord and cover in the back to loosen the UV cover see figure 1 and 9 4 Loosen and remove the three screws on top of the UV cover see figure 2 5 Remove the UV cover and set aside see figures 3 4 6 Remove the two screws and the plastic retainer clip that hold th...

Page 4: ...slot in the UV cover Be sure to line up the two slots in the front of the UV cover with the two prongs behind the discharge connection Push down on the UV cover and line up the arrow on the UV cover with the arrow on the retaining ring see figure 9 16 Twist the UV housing back to desired position and tighten the screws down on the retaining ring UV Sleeve Replacement and Cleaning 1 Make sure the u...

Page 5: ...r clip with the two screws see figure 5 15 Make sure to line up the power cord in the back with the slot in the UV cover see figures 3 9 16 Install the UV light cover and screw down the retaining ring see figure 1 17 Reattach the barbed fittings to the pressure filter Pressure Filter Cleaning 1 There is a cleaning indicator on the top of the filter It will be green in normal operation When the fil...

Page 6: ...our pressure filter 9 If there is excess build up in the bottom of the pres sure filter you can rinse it out but do not clean 100 This is where the beneficial bacteria grow see figure 21 10 Replace the filter pads and install the lid assembly and clamp down with retaining clips or tension ring see figures 16 18 11 If for some reason the large o ring comes off it is best to put it back on the lid a...

Page 7: ...4 1 3 4 1 11 4 11 2 11 4 11 2 11 4 11 2 11 4 11 2 Recommended maximum GPH 600 600 1350 1350 2000 2000 Replacement Filter Part ECF10F ECF10F ECF25F ECF25F ECF25F ECF25F UV Bulb Part None 10UB None 25UB None 40UB UV Sleeve Part None 10US None 25US None 40US Inlet Outlet Hose Barb Part BARB1 BARB1 BARB2 BARB2 BARB2 BARB2 Fish load amount of sunlight etc all affect actual maximum gallons filtered 7 ...

Page 8: ... to pay the return shipping charges Be sure to include the RA number original receipt in the form of an invoice or sales receipt name return address and phone number inside of the pack age No warranty claims will be honored without the original receipt Ensure the product is properly packaged and insured for the replacement value Damage due to im proper packaging is the responsibility of the sender...