MATCH LIGHT FIRE AND START-UP

1. Filling the Hopper and Start-Up:

CAUTION:  FUEL HOPPER LID MUST BE CLOSED
BEFORE OPERATING UNIT.  MAINTAIN HOPPER
SEAL IN GOOD CONDITION.  DO NOT OVERFILL
HOPPER!  THE EASYFIRE WILL HOLD ABOUT 60 LBS.
OF PELLETS.

Open the top lid and fill the hopper with pellets (

Figure

11

).

Make sure hopper lid is fully closed. Open the front

door and fill the burn pot with a hand full of pellets.

IMPORTANT:

 The air-wash and burn tray must be

seated flush and must sit even in the tray. Air leaking
around the burn tray will create a poor burn (

Figure 14)

.

Light the pellets in Fire Pot using any approved pellet fuel
starter.

Allow pellets to burn for approximately 1 minute, or

until pellet ignition has been achieved. 

Close door 

and

turn the control knob to the 

"FAN"

 position. Allow fire to

burn for several minutes. When the pellets are well lit, turn
the control knob to 

"LOW"

 for approximately 10 minutes

then turn up to 

"HI"

.  We recommend that you run the

heater on “Medium” or "HI" for about 30 minutes in order
to get the heat exchanger hot before turning it to "LOW". 
You will need to burn the heater for a few hours before
deciding which setting is best for your particular needs.

NOTE: CAUTION MUST BE TAKEN WHEN
INSTALLING BURN POT OR OPERATING DOOR NOT
TO DAMAGE CERAMIC GLASS. DO NOT ATTEMPT TO
OPERATE HEATER IF GLASS BECOMES DAMAGED
IN ANY WAY!

CAUTION: BOTH THE MAIN DOOR AND THE ASH
DRAWER MUST BE PROPERLY ADJUSTED AND
FULLY CLOSED TO FORM AN AIR-TIGHT SEAL FOR
PROPER STOVE OPERATION. FAILURE TO SECURE
DOOR AND DRAWER MAY CAUSE OVER FEEDING
AND HIGH TEMPERATURE SHUT DOWNS.

DO NOT USE GRATES OR OTHER METHODS OF
SUPPORTING FUEL IN BURN POT OR INTERIOR OF
STOVE.

2. Control Functions:

  Control functions on the Easyfire

are as follows:  OFF, FAN, LOW, MEDIUM, HIGH,
CLEAN. Here is how each function works:

A.

When the Control Knob is turned to 

FAN

, a timer is

activated and you will have about ten (10) minutes to
get the pellets lit and reach a minimum temperature. 
Should the pellets not light in the 10 minutes simply
turn the knob to 

OFF

 and begin again.  This will give

you another 10 minutes to get the pellets lit.  The
reason for the timer function is so that the heater will
automatically shut down if the fire goes out.  Pellets do
not feed in the FAN position.

B.

In the 

LOW

 position, the EASYFIRE will be feeding

approximately 1 to 1½ lbs. of pellets per hour and the
flame will fluctuate between 1" and 6" in height.

C.

In the 

MEDIUM

 position the EASYFIRE will be feeding

approximately three (3) pounds of pellets per hour and
the flame will fluctuate between 3" and 8" of fire.

D.

In the 

HIGH

 position the EASYFIRE will be feeding

approximately 4.5 lbs. per hour and the flame will
fluctuate between 3" and a full flame.  The fan speed will
increase accordingly as the heater automatically adjusts
itself based on temperature inside the heater (see G
below).

E.

The 

CLEAN

 position is to be used only when the heater

is not burning and you wish to clean out the accumulated
ash in the front of the fire area. See 

CLEAN OUT

section of maintenance instructions.

F.

After the heater is running for several hours and you
wish to turn it off simply turn the knob to 

OFF

The

heater will continue running until it cools down and
then will automatically shut itself down

.

G. REMEMBER:

  Each feed position will fluctuate because

the microprocessor is automatically adjusting the feed
and air based on temperature. This means the pellet
feed rate and flame height will change accordingly
based on quality of pellet and heat loss of dwelling.

DISPOSAL OF ASHES

To dump ash from firebox, move lever to left several times
allowing spring to return against stop 

(Figure 10 & 11)

.

Once ash box is full, box should be placed in a non-
combustible floor or on the ground, well away from all
combustible materials pending final disposal. If the ashes
are disposed of by burial in soil or otherwise locally
dispersed, they should be retained in the closed container
until all cinders have been thoroughly cooled.

OPTIONAL 12V HOOK-UP & OPERATION

1.

The EASYFIRE 12V back up can be purchased as an
option and includes the following components:

a.

Deep cycle sealed 12V battery.

b.

Battery connector cables for hook-up to the heater.

2.

In order to hook-up the battery and engage the 12V
backup system simply connect red cable to red terminal
on the heater 

(see Figure 6)

 and to positive connector

on battery [the terminal marked (+)] and connect the
black cable to the black terminal on the heater and to
the negative connector on the battery (the terminal
marked (-). If you hook up the cables backwards the red
LED light above the terminal receptacles will come on. If
hooked up properly this LED will glow green.

WARNING - MAKE SURE RED CABLE GOES TO RED
TERMINAL (POSITIVE CONNECTOR) AND BLACK
CABLE GOES TO BLACK TERMINAL (NEGATIVE
CONNECTOR).

3.

If you decide to purchase your own 12V back up system
we recommend a sealed gel cell battery. Failure to
install the proper battery could cause physical harm to
you and your property and will also void the heater
warranty.

4.

When the battery is properly connected and the heater
plugged in, the following will happen automatically:

a.

The heater will automatically switch to 12V power if
there is a power failure, and switch back when power
is restored.

b.

The battery will be trickle charged as long as the
heater is plugged into 110 AC wall outlet. Do not use

7

Summary of Contents for EF5001C-AL

Page 1: ...all warranties This unit has been approved for use with a 3 Type L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or fres...

Page 2: ...ector pipe shall be fastened with at least three screws If vented horizontally joints shall be made gas tight by sealing with high temperature silicon or material specified by vent pipe manufacturer F...

Page 3: ...exhaust vent into an existing chimney a tee must be installed behind the heater before going up into the chimney This is necessary in order to remove fly ash accumulation 6 Exit termination distance...

Page 4: ...ire for the installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 fee...

Page 5: ...moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a...

Page 6: ...e EASYFIRE will be feeding approximately 4 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater automatically adjusts itself based...

Page 7: ...e D In the HIGH position the EASYFIRE will be feeding approximately 4 5 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater autom...

Page 8: ...are installed MAINTENANCE PROCEDURE CAUTION MOVING PARTS MAY CAUSE INJURY DO NOT OPERATE WITH REAR COVER REMOVED WARNING RISK OF ELECTRICAL SHOCK DISCONNECT ALL POWER BEFORE SERVICING ALWAYS TURN YOUR...

Page 9: ...mparable product and a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is C...

Page 10: ...tion The heater incorporates a safety switch that will disable the feed system when the hopper door is open If fuel is to be added while heater is in operation it must be accomplished with in several...

Page 11: ...9 202164 BURN POT SCREEN AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE PUSH BUTTON SWITCH 12 120114 MAIN CONTROL BOARD V2 2 A L 13 10475 COMBUSTION CONVECTION FAN ASSY 14 110070 CONVECTION FAN...

Reviews: