EasyFire EF5001C-AL Installation & Operating Instructions Manual Download Page 6

Warning: This stove incorporates a hopper lid
safety switch. The feed system will remain in-
operable when the door is open.

Figure 15

Prior to stove operating on thermostat, confirm proper
operation  by  servicing  and  adjusting  the  stove  as
outlined  in  the  “Installation  Guide”.  When  servicing
stove, operate with thermostat bypassed as stove will
reset  to  start  up  mode  each  time  thermostat  is
activated.

START-UP AND OPERATION

Priming the Feed System

When the stove has run out of fuel the feed systems
requires several start and stop cycles to charge the auger.
Pushing the Low button from Off will start the feed for 40
seconds. When the feed stops cycle to Off then back to
Low for another 40 seconds. When pellets begin to fall in
the burn pot switch to Off. You are now ready to start the
stove.

1. AutoLite Start-Up:

Prior to operating your AutoLite stove, make sure the
hopper is full of wood pellets and the interior components
have been installed properly including; burn screen & pot,
heat exchange covers, and ash drawer.

IMPORTANT:

 The Fire Pot must be seated flush and

must sit even in the pot tray. Air leaking around the Fire
Pot will create a poor burn (

Figure 12)

. Confirm Air Wash

is installed in fire box as noted in 

Figure 13.

Note: Caution must be taken when installing burn pot
or operating door not to damage ceramic glass. Do
not attempt to operate heater if glass becomes
damaged in any way!

2. AutoLite Control Functions:

  Control functions on

the Easyfire are as follows:  OFF, FAN, LOW, MEDIUM,
HIGH, CLEAN. Here is how each function works:

A.

When the Control Button is turned to 

FAN

, a timer is

activated and you will have about twenty (20) minutes
to get the pellets lit and reach a minimum temperature.
This function is used for

 Match Lighting 

when the AC

power is out.

Should the pellets not light in 20 minutes simply turn
the button to 

OFF

 and begin again.  This will give you

another cycle to get the pellets lit.  The reason for the
timer function is so that the heater will automatically
shut down if the fire goes out.  Pellets do not feed in
the FAN position.

B.

In the 

LOW

 position, the EASYFIRE will be feeding

approximately 1 to 1½ lbs. of pellets per hour and the
flame will fluctuate between 1" and 6" in height.

C.

In the 

MEDIUM

 position the EASYFIRE will be feeding

approximately three (3) pounds of pellets per hour and
the flame will fluctuate between 3" and 8" of fire.

D.

In the 

HIGH

 position the EASYFIRE will be feeding

approximately 4+ lbs. per hour and the flame will
fluctuate between 3" and a full flame.  The fan speed will
increase accordingly as the heater automatically adjusts
itself based on temperature inside the heater.

E.

The 

CLEAN

 position is to be used only when the heater

is not burning and you wish to clean out the accumulated
ash in the front of the fire area. See 

CLEAN OUT

section of maintenance instructions.

F.

After the heater is running for several hours and you
wish to turn it off simply press the button to 

OFF

The

heater will continue running until it cools down and
then will automatically shut itself down

.

G. REMEMBER:

  Each feed position will fluctuate because

the microprocessor is automatically adjusting the feed
and air based on temperature. This means the pellet
feed rate and flame height will change accordingly
based on quality of pellet and heat loss of dwelling.

3. Starting the Stove: 

Push a Heat Range button (Low or

Medium is best for start up) (

Figure 15

) and turn the

thermostat up to 

“Call for heat”

. The stove fan will begin to

operate along with the ignitor cycle. After about a minute the
pellets will begin to fall in the burn pot. After five minutes
there will be a fire in the burn pot and the stove will begin to
heat up. When the stove reaches start up operating
temperature it will then switch to the control panel setting
and begin it’s automatic operation cycle.

Feed Trim & Draft Adjustment

Underneath the control button you will find a small round
button that will turn forward and reverse.  This button can
adjust the feed motor in the LOW operating position. By
turning the button clockwise you can increase the feed on
LOW and by turning it counterclockwise you can decrease
the feed in the LOW position. Factory setting is 9:00 o’clock.
The draft handle is located on the right side and allows
adjustment of incoming air. This varies by installation and
condition of the flue (clean or dirty). Start with the handle at
8:00 

(Figure 14

). To much air will cause the fire to go out

and not enough will cause the burn pot to fill with ash.

Once the stove is at operating temperature set the stove
on LOW. Adjust the trim button so that average flame is
approx. 1-2" above the burn pot. This will set the
average feed rate (air/flue) for best operation.

Move these controls carefully!

  It is designed to fine tune

your your setting in the event you change brands of pellets
and/or live at a higher elevation. If this setting is to low the
stove may go out during normal  operations. If this should
happen increase the trim and reduce the draft by small
amount. 

6

Summary of Contents for EF5001C-AL

Page 1: ...all warranties This unit has been approved for use with a 3 Type L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or fres...

Page 2: ...ector pipe shall be fastened with at least three screws If vented horizontally joints shall be made gas tight by sealing with high temperature silicon or material specified by vent pipe manufacturer F...

Page 3: ...exhaust vent into an existing chimney a tee must be installed behind the heater before going up into the chimney This is necessary in order to remove fly ash accumulation 6 Exit termination distance...

Page 4: ...ire for the installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 fee...

Page 5: ...moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a...

Page 6: ...e EASYFIRE will be feeding approximately 4 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater automatically adjusts itself based...

Page 7: ...e D In the HIGH position the EASYFIRE will be feeding approximately 4 5 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater autom...

Page 8: ...are installed MAINTENANCE PROCEDURE CAUTION MOVING PARTS MAY CAUSE INJURY DO NOT OPERATE WITH REAR COVER REMOVED WARNING RISK OF ELECTRICAL SHOCK DISCONNECT ALL POWER BEFORE SERVICING ALWAYS TURN YOUR...

Page 9: ...mparable product and a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is C...

Page 10: ...tion The heater incorporates a safety switch that will disable the feed system when the hopper door is open If fuel is to be added while heater is in operation it must be accomplished with in several...

Page 11: ...9 202164 BURN POT SCREEN AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE PUSH BUTTON SWITCH 12 120114 MAIN CONTROL BOARD V2 2 A L 13 10475 COMBUSTION CONVECTION FAN ASSY 14 110070 CONVECTION FAN...

Reviews: