Figure 1

 -

Overall Dimensions

Figure 2

Under specific test conditions this heater has been
shown to deliver heat at rates ranging from 

9,527

to 

18,761 

Btu/hr.

THIS APPLIANCE NEEDS PERIODIC INSPECTION AND
REPAIR FOR PROPER OPERATION. CONSULT
OWNER’S MANUAL FOR FURTHER INFORMATION. IT
IS AGAINST FEDERAL REGULATIONS TO OPERATE
THIS APPLIANCE IN A MANNER INCONSISTENT WITH
OPERATING INSTRUCTIONS IN THE OWNER’S
MANUAL.

This wood heater has a manufacturer-set minimum
low burn rate that must not be altered. It is against
federal regulations to alter this setting or otherwise
operate this wood heater in a manner inconsistent
with operating instructions in this manual.
U.S. ENVIRONMENTAL PROTECTION AGENCY
Certified to comply with 2020 particulate emission
standards using pellet fuel.
It is recommended that smoke and carbon monoxide
detectors be installed in the area where the heater is to be
installed.

OUTSIDE COMBUSTION AIR IS MANDATORY IN
MOBILE OR MODULAR HOME INSTALLATIONS.

CAUTION: DO NOT CONNECT TO ANY AIR
DISTRIBUTION DUCT OR SYSTEM.

VENTING AND INSTALLATION
CLEARANCES

CONTACT LOCAL BUILDING OFFICIALS ABOUT RE-
STRICTIONS AND INSTALLATION INSPECTION
REQUIREMENTS IN YOUR AREA.

A LISTED, 3" MINIMUM TYPE "L" PELLET VENT PIPE IS
MANDATORY ON ALL INSTALLATIONS.

DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST
VENTING SYSTEM OF THIS UNIT, DO NOT CONNECT
THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER
APPLIANCE.

Use only listed 3" minimum Type "L" pellet vent and
components for installation. The exhaust vent system must
be attached to the unit and to each adjoining section. All
joints for connector pipe shall be fastened with at least three
screws. If vented horizontally, joints shall be made gas-tight
by sealing with high temperature silicon or material specified
by vent pipe manufacturer. Failure to use listed pellet vent
pipe or install it per manufacturers instructions will void your
warranty.

INSTALL VENT AT CLEARANCES SPECIFIED BY THE
VENT MANUFACTURER
Vent Pipes’ inner and outer diameters may vary. Check with
vent pipe manufacturer for further details. 

WARNING: Installation of a Mobile Home Attachment Kit
P/N 10412 and outside combustion air is mandatory in
mobile or modular home installations

 although it may

also be used in all residential applications.

An outside air inlet MUST be provided for combustion
and ventilation air.

  The air inlet must remain unrestricted

while unit is in use.  Outside air connection is located in the
rear of the heater (

Figure 2

). Use conduit pipe or metal flex

pipe and/or fittings to make the air intake hook-up.

CAUTION: STRUCTURAL INTEGRITY OF THE MOBILE
HOME FLOOR, WALLS AND CEILING/ROOF MUST BE
MAINTAINED.

1.

When deciding on the location of your heater and vent
pipe, try to minimize the alteration and reframing of
structural components of the building. 

Vent pipe must

be installed so that access is provided for
inspection and cleaning

.

2.

Avoid installing heater in high traffic areas. Keep
children well away from the heater when in operation.

3. A 3" clearance to combustibles must be maintained

for horizontal and vertical venting. When passing
through ceilings or walls, you must use a listed wall

PELLET HEATERS REQUIRE A MINIMUM 5' VERTICAL
RISE FOR PROPER OPERATION. ADDITIONAL RISE
OF  2'  FOR  EVERY  1'  HORIZONTAL  BEYOND  1  ½'.
MINIMUM  DRAFT  REQUIRED  IS  -.01  IN.WC.  @
CONNECTION

.

LOW DRAFT CONDITIONS RESULT IN OVERFEEDING
AND POOR COMBUSTION. 

2

Summary of Contents for EF5001C-AL

Page 1: ...all warranties This unit has been approved for use with a 3 Type L Pellet Vent System NEVER use gasoline gasoline type lantern fuels kerosene charcoal lighter fluid or similar liquids to start or fres...

Page 2: ...ector pipe shall be fastened with at least three screws If vented horizontally joints shall be made gas tight by sealing with high temperature silicon or material specified by vent pipe manufacturer F...

Page 3: ...exhaust vent into an existing chimney a tee must be installed behind the heater before going up into the chimney This is necessary in order to remove fly ash accumulation 6 Exit termination distance...

Page 4: ...ire for the installation a Unplug heater from wall outlet and 12VDC power b Remove factory jump wire and hook up thermostat wires to terminals Figure 7 8 c Locate thermostat approximately 10 to 12 fee...

Page 5: ...moisture level above 5 The quality of pellet fuel varies from brand to brand This will affect the efficiency of your heater We suggest that you try several brands until you find one that gives you a...

Page 6: ...e EASYFIRE will be feeding approximately 4 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater automatically adjusts itself based...

Page 7: ...e D In the HIGH position the EASYFIRE will be feeding approximately 4 5 lbs per hour and the flame will fluctuate between 3 and a full flame The fan speed will increase accordingly as the heater autom...

Page 8: ...are installed MAINTENANCE PROCEDURE CAUTION MOVING PARTS MAY CAUSE INJURY DO NOT OPERATE WITH REAR COVER REMOVED WARNING RISK OF ELECTRICAL SHOCK DISCONNECT ALL POWER BEFORE SERVICING ALWAYS TURN YOUR...

Page 9: ...mparable product and a soft clean cloth to wipe any marks off all gold surfaces or the heat will cause the marks to remain in the surface permanently Always clean the gold surface when the heater is C...

Page 10: ...tion The heater incorporates a safety switch that will disable the feed system when the hopper door is open If fuel is to be added while heater is in operation it must be accomplished with in several...

Page 11: ...9 202164 BURN POT SCREEN AL 10 120120 AUTOLITE POWER RELAY 11 120118 AUTOLITE PUSH BUTTON SWITCH 12 120114 MAIN CONTROL BOARD V2 2 A L 13 10475 COMBUSTION CONVECTION FAN ASSY 14 110070 CONVECTION FAN...