EDC212S
Address: Room 402, Building B, Hangcheng Industrial Zone, Chentian, Xixiang Street, Baoan District, Shenzhen
Phone: 0755-27788421
Website: http://www.easydetek.com
Shenzhen EasyDetek Technology Co.,Ltd
- 3 -
Typical application products
Ceiling light
Three anti-light Moisture-proof lamp
*The above are typical application products, which can be expanded to more products
Product information
Model
Function description
EDC212S-A
4-digit dialing code for forward installation (same side as antenna)
EDC212S-B
4 digit dialing code installed backwards (on the opposite side of the antenna)
EDC212S-C
No dial code, infrared remote control adjustment (same side as antenna)
DIP switch settings
First place: Sensing distance setting
1
100%
ON
50%
-
According to different applications, the sensing distance can be adjusted by the code switch to set 100%, 50%
The second and third digits: delay time setting
2
3
5s
ON
ON
1min
ON
-
3min
-
0N
5min
-
-
Delay time refers to the time that the light is on after the moving object leaves the sensing area. The gears can be set: 5s,
1min, 3min, 5min