Detection diagram

(distance can be adjusted according to actual application)

Detection sensitivity gear:

Ceiling installation diagram

Precautions

1. When installing the product, the antenna board is required to maintain a certain height from the metal plane. It is

recommended that the antenna board be kept at a distance of 5-12mm from the metal plane. It should not be close to or

touch the metal plane, otherwise the product may not work properly!

2. The product has a better penetration effect on plastic and wood. At the same time, avoid metal shielding in front of

the antenna, which will reflect microwaves and affect the actual sensing effect;

3. Installing glass in front of the antenna will cause electromagnetic wave reflection and penetration attenuation, which

will reduce the sensing distance of the sensor; installing ceramics in front of the antenna will also produce penetration

attenuation, the greater the thickness, the more serious the attenuation;

4. Please use a power supply with a small ripple for power supply, especially low-frequency ripples are likely to interfere

with the operation of the sensor and cause false alarms. The recommended power supply capacitor is 470 uF; it is

recommended that the power supply ripple be guaranteed within 100mV, and the ripple of 50mV is better;

5. The signal output of the sensor, the load current capacity is weak, it may not be able to directly drive the back-end

equipment.

6. When multiple sensors are used in the same site, the spacing should be greater than 0.5m. It is recommended that the

product installation spacing be greater than 1.5m. Too close installation distance may cause false alarms in individual

cycles;

7. Avoid high current circuit coverage on the antenna surface. The electromagnetic field generated by the circuit loop will

Summary of Contents for EDC212S

Page 1: ...Room 402 Building B Hangcheng Industrial Zone Chentian Xixiang Street Baoan District Shenzhen Phone 0755 27788421 Website http www easydetek com Shenzhen EasyDetek Technology Co Ltd 1 EDC212S A EDC21...

Page 2: ...power consumption 0 5W Sensing distance 5 6m Power supply frequency 50Hz 60Hz Delay time EDC212S A EDC212S B 5s 1min 3min 5min EDC212S C 10s 30s 1min Photosensitive threshold EDC212S A EDC212S B 25Lux...

Page 3: ...git dialing code for forward installation same side as antenna EDC212S B 4 digit dialing code installed backwards on the opposite side of the antenna EDC212S C No dial code infrared remote control adj...

Page 4: ...ce photosensitive threshold setting 4 25Lux ON Disable When the ambient illuminance value is lower than the set valve an object moves in the sensing area The stalls are 25Lux all day Pin description E...

Page 5: ...ial Zone Chentian Xixiang Street Baoan District Shenzhen Phone 0755 27788421 Website http www easydetek com Shenzhen EasyDetek Technology Co Ltd 5 EDC212S C Pin Pin Description L out Fire wire out N o...

Page 6: ...5 27788421 Website http www easydetek com Shenzhen EasyDetek Technology Co Ltd 6 Infrared remote control settings Product size chart 100 4 6m 75 3 4 5m 50 2 5 4m 25 1 5 2m 10s select time 10s 30s sele...

Page 7: ...om 402 Building B Hangcheng Industrial Zone Chentian Xixiang Street Baoan District Shenzhen Phone 0755 27788421 Website http www easydetek com Shenzhen EasyDetek Technology Co Ltd 7 EDC212S A Unit mm...

Page 8: ...n When the ambient light is bright enough the light will not automatically light up even if a moving object is detected When the ambient light is lower than the preset photosensitive threshold the lig...

Page 9: ...9 Photosensitive function is off Packaging Information Support packaging Blister packaging Bubble bag packaging PE bag packaging No moving objects can be detected and the lamp goes out When the sensor...

Page 10: ...use electromagnetic wave reflection and penetration attenuation which will reduce the sensing distance of the sensor installing ceramics in front of the antenna will also produce penetration attenuati...

Page 11: ...ers 400nm 1100nm including visible light LED tube infrared light band the illuminance value detected by light sensing may be different at different time periods and under different weather conditions...

Page 12: ...Xixiang Street Baoan District Shenzhen Phone 0755 27788421 Website http www easydetek com Shenzhen EasyDetek Technology Co Ltd 12 Configuration version description hardware software History revision...

Page 13: ...harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or t...

Reviews: