INSTALL THE VACUUM/FILTER ASSEMBLY
TO THE BLAST CABINET
• Place the Vacuum/Filter Assembly on the floor and unlatch
the two latches.
• Pull the Motor & Filter out of the top of the Housing and set
it aside.
• Before mounting, now is a good time to install the Plunger
Assembly
[T]
to the Housing. Unthread and separate the
2 sections of the Plunger Assembly, leaving the Spring in
place over the stem.
• Insert the Plunger stem with the Spring into the open port
of the Housing wall
(FIG 13a)
.
• Thread the inner Striker Head onto the threaded stem and
lock into place with the supplied Locknut
(FIG 13b)
.
• With the assistance of a helper, align the mounting holes
of the brackets with the four holes at the right rear wall of
the Blast Cabinet. Secure it in place using four M6 x 12mm
Pan Head Screws
[M]
and M6 Serrated Flange Nuts
[N]
(FIG 13c
).
• Carefully lower the Motor/Filter Assembly back into the
mounted Housing and relatch it securely
(FIG 14 )
.
• Connect the Plug on the power supply cord with the female
Receptacle on the cord attached to the Light Fixture
(FIG 15 )
.
The Vacuum/Filter Assembly is moderately heavy,
and it is best to remove the Motor and Filter
before installing on the Blast Cabinet. Also, the
assistance of a capable helper is necessary.
FIG. 13
FIG. 13cc
FIG. 14
FIG. 14
FIG. 15
FIG. 15
Vacuum/Filter
Vacuum/Filter
Assembly
Assembly
screw holes
screw holes
✓
✓
✓
✓
FIG. 13
FIG. 13aa
FIG. 13
FIG. 13bb