8
Eastwood Technical Assistance: 800.343.9353 >> [email protected]
FIG. 9
FIG. 9
FIG. 10
FIG. 10
FIG. 12
FIG. 12
INSTALL THE PERFORATED BLAST CABINET FLOOR
• Let the Blasting Gun and Hoses hang out of the right front
corner of the Blast Cabinet.
• Insert the Perforated Floor Panel
[F]
through one of the Blast
Cabinet side openings with the angled cut off corner toward
the right front of the Cabinet to allow space for the hoses
(FIG 9
). Rest the edges on the internal support flanges.
MOUNT THE AIR REGULATOR/FOOT PEDAL ASSEMBLY
• Set the Air Regulator in place on the upper front face of the
left leg, align the mounting holes of the bracket with the two
holes in the Leg and secure it by installing two M6 x 12mm
Pan Head Screws
[M]
and M6 Serrated Flange Nuts
[N]
(FIG 10)
.
MOUNT THE ANTI-PURGE VALVE
• Install the Anti-Purge Valve by installing three M6 x 12mm
Pan Head Screws
[M]
and M6 Serrated Flange Nuts
[N]
through the hinge into the back of the Blast Cabinet
(FIG 11)
.
• Use the latch on the front of the Blast Cabinet to lock the
Anti-Purge Valve door closed
(FIG 12)
.
• Verify the latch is creating adequate pressure on the seal so
that media does not leak. If not, adjust the latch clockwise
to increase pressure
(FIG 12)
until the seal is adequate and
media will not leak.
FIG. 11
FIG. 11
Angled cut-off corner for Hose clearance
Angled cut-off corner for Hose clearance
(front right of Blast Cabinet)
(front right of Blast Cabinet)
✓
Air Regulator
Air Regulator
screw holes
screw holes
✓
✓
Anti-Purge Valve
Anti-Purge Valve
screw holes
screw holes
✓
✓
✓
✓
Closed
Closed
Rotate clockwise to
Rotate clockwise to
increase tension
increase tension