© Copyright 2016 Easthill Group, Inc.
4/16 Instruction item #20484Q Rev 0
See our complete line of consumables and parts at
www.eastwood.com
ACCESSORIES
#19055A
Flap Disc 60 Grit 4.5” Diameter 7/8” Hole
#12590
Welding Gloves Large
#12589
Welding Gloves Medium
#13203
Auto Darken Welding Helmet
#13212
Large View Auto Darken Welding Helmet
#19079S
Stainless Steel Brush
#51139
Copper 3 x 3 Welders Helper Set
#50739
Master Welder’s Helper Panel Holding Kit
#12762L, XL, XXL
Welding Jacket
#19001
Welding Rod 1/16” Diameter, 3 lbs.
#20358
ARC Welder TIG Torch
#12238
Welding Gas Regulator
#20277
Eastwood Welding Flow Meter
If you have any questions about the use of this product, please contact
The Eastwood Technical Assistance Service Department: 800.544.5118 >> email: [email protected]
PDF version of this manual is available online >> eastwood.com/20484manual
The Eastwood Company 263 Shoemaker Road, Pottstown, PA 19464, USA
US and Canada: 800.345.1178 Outside US: 610.718.8335
Fax: 610.323.6268 eastwood.com
TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Difficulty
Starting Arc
Incomplete Circuit
Check Ground connection. Make sure that the ground is on a freshly cleaned
surface and close to the welding area. It is suggested to weld toward the
ground connection
Amperage Too Low
Based on the material welding & size/material of the electrode, pick an
appropriate amperage to perform the desired weld.
Contaminated Base Metal
Clean base metal of any oil, debris, coatings, or moisture. If base metal is cold
rolled steel make sure to remove any mill scale.
Arc Wander
Electrode too far from welding surface
Move electrode so that it is contacting the weld puddle and feed rod into the
puddle as needed.
Difficulty
Holding Arc
Amperage Too Low
Based on the material welding and size/material of the electrode, pick an
appropriate amperage to perform the desired weld.
Electrode too far from welding surface
Move electrode so that it is contacting the weld puddle and feed rod into the
puddle as needed.
Incomplete Circuit
Check Ground connection. Make sure that the ground is on a freshly cleaned
surface and close to the welding area. It is suggested to weld toward the
ground connection.
Contaminated Electrode Rod
Make sure that Electrodes are clean and dry before use.
Contaminated Base Metal
Clean base metal of any oil, debris, coatings, or moisture.