background image

Some products may not be available in your country, please contact our distributor for more details

Some products may not be available in your country, please contact our distributor for more details

11

12

6.OSD - Map

MAIN

MENU

SYSTEM

SETTING

CAMERA

SETTING

FUNCTION

SETTING

WINDOW

BLANKING

EXIT

SYSTEM

SETTING

EDIT

DOME

L

ABEL

INITIAL

I

NFO

DISPLA

Y

SETUP

MOTION

CLEAR

BACK

EXIT

P

A

SSWORD

S

ETUP

CAMERA

SETTING

ZOOM

SPEED

HIGH

DIGIT

A

L

Z

OOM

BLC

M

ODE

OFF

SLOW

SHUTTER

ON

IR

CUT

F

IL

TER

AUT

O

WDR

M

ODE

ADV

ANCE

S

ETTING

OFF

LI)NE

S

YNC

OFF

OFF

BACK

EXIT

FUNCTION

SETTING

AE

MODE

A

UTO

SHUTTER

N

/A

IRIS

N

/A

BRIGHT

N

/A

W

MODE

A

UTO

R

GAIN

N

/A

B

GAIN

N

/A

BACK EXIT

B

PRESETS

SCAN

SCAN

SPEED

2

0

SET

LEFT

LIMIT

SET

RIGHT

LIMIT

CLEAR

SCAN

RUN

SCAN

EDIT

SCAN

LABEL

BACK EXIT

PATTERNS

PATTERN

NUMBER

1

PROGRAM

PATTERN

RUN

PATTERN

CLEAR

PATTERN

EDIT

PATTERN

LABEL

BACK EXI

T

--

--

T

OUR

DWELL

004

RUN

T

OUR

BACK EXIT

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

00

--

-

--

----

-

--

----

-

ZONES

ZONES

NUMBER

1

SET

LEFT

LIMIT

SET

RIGHT

LIMIT

CLEAR

ZONE

EDIT

ZONE

LABEL

BACK EXIT

DOME

LABEL

OFF

PRESET

LABEL

OFF

ZOOM

LABEL

O

ZONE

LABEL

OFF

DIRECTION

LABEL

O

TEMPERATURE

LABEL

OFF

BACK EXIT

FF

FF

MOTION

AUTO

FLIP

ON

PROPORTION

PAN

ON

PARK

TIME

00

PARK

ACTION

POWER

UP

ACTION

FAN

ENABLED

040

BACK EXIT

0

NONE

NONE

INITIAL

INFO

SPEED

DOME

V

PROTOCOL

:

DOME

ADDRESS:

001

COMM:

00

.

N.8.1

BACK EXIT

1.03

PELCO

96

PRESET

NUMBER

0

01

SET

PRESET

SHOW

PRESET

CLEAR

PRESET

EDIT

PRESET

LABEL

BACK EXIT

LABEL:

PRESET-01

BACK EXIT

EDIT

PRESET

LABEL

LABEL:

AUTO

SCAN

BACK EXIT

EDIT

SCAN

LABEL

LABEL:

PATTERN-1

BACK EXIT

EDIT

PATTERN

L

ABEL

LABEL:

ZONE-1

BACK EXIT

EDIT

ZONE

LABEL

LABEL:SPEED

DOME

BACK EXIT

1.00

EDIT

DOME

LABEL

DISPLAY

SETUP

ADVANCE

SETTING

PRESETS SCAN PATTERNS TOUR ZONES

BACK

EXIT

CLEAR

ALL

ZONES

CLEAR

ALL

PRESETS

CLEAR

ALL

PATTERNS

CLEAR

ALL

TOURS

CLEAR

ALL

WINDOWS

FACTORY

DEFAULTS

RESTART BACK EXIT

TOUR

WINDOW

NUMBER

0

1

EDIT

WINDOW

ENABLE

WINDOW

O

CLEAR

WINDO

FF

W

BACK

EXIT

WINDOW

BLANKING

6.OSD - System Setting

System Setting

In the system setting menu, you can modify operation
and display settings, such as dome label, temperature
and display of various values on the operational
screen.

EDIT DOME LABEL

LABEL

BACK

EXIT

ENTRANCE

INITIAL INFO

FIRMWARE 1.03

PLECO

V

PROTOCOL:
DOME ADDRESS:001
COMM:4800,N,8,1
BACK
EXIT

SYSTEM SETTING

EDIT DOME LABEL
INITIAL INFO
DISPLAY SETUP
MOTION
CLEAR
PASSWORD SETUP
BACK
EXIT

Initial Info:

Shows the information about current settings.

Dome Label:

1. use UP or DOWN to change the character.

2. use RIGHT to move to next character.

3. use RIGHT to move to last char. and to save.

4. use Left to go to first char. and to cancel.

Display Setup

Dome label:
Preset label:
Zoom label:
Zone label:
Direction label:
Temperature label:

Enables the display for the on-screen info during
operaton mode.

Name of the dome

Shows the label of every preset

Shows zoom factor on screen

Shows the zone name

Shows the coordinates

Shows the current temp. in

the dome

DISPLAY SETUP

DOME LABEL

OFF

PRESET LABEL

OFF

ZOOM LABEL

ZONE LABEL

OFF

DIRECTION LABEL

O

LABEL

OFF

BACK

OFF

TEMPERATURE

FF

CLEAR

Summary of Contents for PT9600DN

Page 1: ...User Manual English v1 03 Middle Speed Dome Camera Series PT9600DN...

Page 2: ...BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED...

Page 3: ...F to 122 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 1000mA models Do not expose the indoor dome cameramodel to water or moisture do not try to operate it in wet a...

Page 4: ...protection and grounding of the device should be considered Please refer to the industrial saftey regulations of your country Grounding of the appliance should include anti interference and fulfill t...

Page 5: ...ogy Depending on the cable type and baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 400m 4800...

Page 6: ...r Connection The star form connection is a popular way to connect different devices It enables longer distance connection of different dome cameras It is recommended to use RS485 distributor to ensure...

Page 7: ...ud rate Address ID and protocol of both keyboard and the dome are correctly configurated For further details on operating the PTZ please refer to the user s manual of the keyboard OSD Menu How to star...

Page 8: ...R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K E X I T L A B E L P R E S E T 0 1 B A C K E X I T E D I T P R E S E T L A B E L L A B E L A U T O S C A N B A C K E X I T EDIT SC...

Page 9: ...K EXIT 6 OSD Camera Setting ADVANCE SETTING AE MODE AUTO SHUTTER N A IRIS N A BRIGHT N A WB MODE AUTO R GAIN N A B GAIN N A BACK EXIT Advanced Setting Under the advanced setting you can make improveme...

Page 10: ...R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K EXIT Scan SCAN NUMBER SCAN SPEED SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN RUN SCAN EDIT SCAN LABEL The SCAN function moves the P...

Page 11: ...Camera modules 8 masking areas up to 24 masking areas except the 45 series provides only 8 no masking function Mask number Edit position of the mask using the keyboard s joystick Presse IRIS OPEN to s...

Page 12: ...1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0 ID ID 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 34 Some products may not be available in your country please contact our distributor for more details 102 103 104 105 106 107 10...

Page 13: ...0 0 0 1 0 1 1 0 1 0 0 0 1 1 0 0 1 0 0 1 0 1 0 1 1 0 0 0 1 1 1 0 1 0 0 1 0 1 1 1 1 0 0 0 1 1 0 1 1 0 0 1 0 1 0 0 0 1 0 0 1 1 1 1 1 0 0 1 0 1 1 0 0 1 0 0 1 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 1 0 0 1 0 1...

Page 14: ...ideo Output S N Ratio Pan Speed Auto Manua Auto Slow Shutter Auto Manual 3 to 28 dB 2 dB steps 16steps VBS 1 0Vp p Sync Negative Y C Output 0 100 per Sec Shutter Speed 1 3 to 1 10 000 Sec Focus White...

Reviews: