Function Setting

In function setting menu, you can define and activate
different PTZ funcitons, such as preset points, auto
scan, tours and patterns. Presets and tour functions
can also be set or activated directly from the
keyboard without entering the OSD Menu. Please
refer to the keyboard’s manual for operation details.

EDIT PRESET LABEL

LABEL
BACK
EXIT

MAIN ENTR

FUNCTION SETTING

PRESETS
SCAN
PATTERNS
TOUR
ZONES
BACK
EXIT

Presets

PRESET NUMBER:

SET PRESET:

SHOW PRESET:

CLEAR PRESET:

EDIT PRESET LABEL:

supports up to 128 presets. The

number can be selected from 0 to 128.

Defining the preset points directly in

OSD by entering this menu item and move the PTZ.
Press IRIS-OPEN key on the keyboard to save. If the
preset is pointed within digital zoom, it will
automatically go back to the max. optical zoom range
in order to provide the best image quality.

Moves to the current preset point.

Clears the current preset.

For the current preset, you

can define a name which will be displayed on the
operation screen once the preset is called. Please
choose the preset number first. The avaialbe
characters are: 0-9, A-Z, <,>,. and space.

PRESETS

P R E S E T N U M B E R

0 0 1

S E T P R E S E T
S H O W P R E S E T
C L E A R P R E S E T
E D I T P R E S E T L A B E L
B A C K
E X I T

Scan

SCAN NUMBER:
SCAN SPEED:
SET LEFT LIMIT:
SET RIGHT LIMIT:
CLEAR SCAN:
RUN SCAN:
EDIT SCAN LABEL:

The SCAN function moves the PTZ between 2-
predefined points with constant speed. The following
parameters can be set:

Cruising speed between the points.

Defines the left point.

Defines the right point.

Deletes the scan setting.

Starts the scan function.

Sets the name for the scan.

Supports up to 4 scans.

SCAN

SCAN SPEED

20

SET LEFT LIMIT
SET RIGHT LIMIT

RUN SCAN
EDIT SCAN LABEL
BACK
EXIT

CLEAR SCAN

16

6.OSD - Patterns, Tours

Patterns

Patterns record the user ’s movement while
performing PTZ operations and stores them as a
track. The Speed Dome can record up to 4 tracks
with max. 180 sec. each.

PATTERN NUMBER:

PROGRAM PATTERN:

RUN PATTERN:

CLEAR PATTERN:

EDIT PATTERN LABEL :

Supports up to 4 patterns.

Starts recording the

pattern when selected. You can perfom PTZ
movements for recording (not exceeding 180 sec.).
Press IRIS-OPEN to save the track.

Starts the current pattern.

Deletes the current pattern.

Sets the name for the

current pattern.

Tour

Tour is an auto-operation running through selected
preset points with definable pause time. A tour can
store up to 24 preset points.

TOUR DWELL (TM):

RUN TOUR:

Pause duration after reaching

a preset point. Duration can be set between 00-
255(s).

Starts the tour and exits the OSD

Menu.

TOUR

PATTERNS

PATTERN NUMBER

1

PROGRAM PATTERN
RUN PATTERN
CLEAR PATTERN
EDIT PATTERN LABEL
BACK
EXIT

TOUR DWELL

004

00-0 00-00

BACK
EXIT

0-

-00-00-00-00

00-00-00-00-00-00-00-00
00-00-00-00-00-00-00-00
RUN TOUR

Summary of Contents for PT9600DN

Page 1: ...User Manual English v1 03 Middle Speed Dome Camera Series PT9600DN...

Page 2: ...BE REQUIRED TO CORRECT THE INTERFERENCE AT HIS OWN EXPENSE WARNING THIS IS A CLASS A PRODUCT IN A DOMESTIC ENVIRONMENT THIS PRODUCT MAY CAUSE RADIO INTERFERENCE IN WHICH CASE THE USER MAY BE REQUIRED...

Page 3: ...F to 122 F and a humidity below 90 The input power source is 24V AC 50 60Hz and requires 1000mA models Do not expose the indoor dome cameramodel to water or moisture do not try to operate it in wet a...

Page 4: ...protection and grounding of the device should be considered Please refer to the industrial saftey regulations of your country Grounding of the appliance should include anti interference and fulfill t...

Page 5: ...ogy Depending on the cable type and baud rate the transmission distance could vary The following table shows max distances based on cable with 0 56mm 24AWG twisted pair 2400 bps 1100 m 700m 400m 4800...

Page 6: ...r Connection The star form connection is a popular way to connect different devices It enables longer distance connection of different dome cameras It is recommended to use RS485 distributor to ensure...

Page 7: ...ud rate Address ID and protocol of both keyboard and the dome are correctly configurated For further details on operating the PTZ please refer to the user s manual of the keyboard OSD Menu How to star...

Page 8: ...R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K E X I T L A B E L P R E S E T 0 1 B A C K E X I T E D I T P R E S E T L A B E L L A B E L A U T O S C A N B A C K E X I T EDIT SC...

Page 9: ...K EXIT 6 OSD Camera Setting ADVANCE SETTING AE MODE AUTO SHUTTER N A IRIS N A BRIGHT N A WB MODE AUTO R GAIN N A B GAIN N A BACK EXIT Advanced Setting Under the advanced setting you can make improveme...

Page 10: ...R E S E T C L E A R P R E S E T E D I T P R E S E T L A B E L B A C K EXIT Scan SCAN NUMBER SCAN SPEED SET LEFT LIMIT SET RIGHT LIMIT CLEAR SCAN RUN SCAN EDIT SCAN LABEL The SCAN function moves the P...

Page 11: ...Camera modules 8 masking areas up to 24 masking areas except the 45 series provides only 8 no masking function Mask number Edit position of the mask using the keyboard s joystick Presse IRIS OPEN to s...

Page 12: ...1 1 0 0 0 0 0 41 1 0 0 1 0 1 0 0 ID ID 0 0 0 0 0 0 0 0 0 1 0 0 0 1 0 0 34 Some products may not be available in your country please contact our distributor for more details 102 103 104 105 106 107 10...

Page 13: ...0 0 0 1 0 1 1 0 1 0 0 0 1 1 0 0 1 0 0 1 0 1 0 1 1 0 0 0 1 1 1 0 1 0 0 1 0 1 1 1 1 0 0 0 1 1 0 1 1 0 0 1 0 1 0 0 0 1 0 0 1 1 1 1 1 0 0 1 0 1 1 0 0 1 0 0 1 1 0 0 0 1 0 1 0 1 0 1 0 1 0 0 1 1 1 0 0 1 0 1...

Page 14: ...ideo Output S N Ratio Pan Speed Auto Manua Auto Slow Shutter Auto Manual 3 to 28 dB 2 dB steps 16steps VBS 1 0Vp p Sync Negative Y C Output 0 100 per Sec Shutter Speed 1 3 to 1 10 000 Sec Focus White...

Reviews: