7) 

MAINTENANCE 

 

Regular  maintenance  including  Testing,  Inspection  and  Cleaning  should  be  carried  out  on 
the  Kibble  to  reduce  the  risk  of  potential  hazards  arising.    In  particular,  thorough  cleaning 
after  operational  use  is  a  must  to  prevent  the  Discharge  Gate,  Handle  and/or  Chute  from 
jamming as well  as making identification of damage  easier. The Kibble should  be cleaned 
and visually inspected by a “Competent Person” under adequate lighting conditions, before 
each  shift,  to  ensure  all  components  are  functioning  correctly  and  are  free  from  any 
noticeable  wear  or  damage,  particularly  at  any  load  bearing  or  highly  stressed  points.    If 
components  are  considered  worn  or  damaged,  or  if  safety  charts  or  labels  are  damaged  or 
illegible,  the  Kibble  should  be  taken  out  of  service  and  East  West  Engineering  or  an 
“Authorised Person” contacted for advice.  Periodic testing may be required if any damage 
is noted, as this could be an indication of abuse or overloading.  Keep maintenance records 
to ensure safety checks are carried out.  
 
 

8) 

COMPLIANCE PLATE INFORMATION

 

 
 

 

 

 
 
 
 
 
 
 
 
 
 

Fig. 8.1 

 
 
 

A

 

Product Type 

Refer “A”, 

Table 8.2

 

B

 

Year of Manufacture 

Individually stamped 

C

 

Working Load Limit 

Refer “C”, 

Table 8.2 

D

 

Dry Weight of the unit 

Refer “D”, 

Table 8.2 

E

 

Serial Number 

Individually stamped 

Volume

 

Refer “F”, 

Table 8.2 

 

 

COMPLIANCE PLATE MARKING

 

Type 

“A” 

“B” 

“C” 

“D” 

“E” 

“F” 

CKM05 

CKM05 

YM 

1500 

275 

Serial No 

0.50 

CKM10 

CKM10 

YM 

3000 

320 

Serial No 

1.00 

CKM15 

CKM15 

YM 

4000 

415 

Serial No 

1.50 

 

Table 8.2 

 

“D” 

“A” 

“B” 

“C” 

“E” 

“F” 

Summary of Contents for CKM05

Page 1: ...Control Measures Summary 6 6 Parts List 9 7 Maintenance 10 8 Compliance Plate Information 10 9 Certification Information 11 10 Terms and Conditions 12 Appendix A Attached ALL EAST WEST CONCRETE KIBBLE...

Page 2: ...of 1500kg and a unit weight of 275kg with a capacity for 0 5 cubic metres of material The type CKM10 Concrete Kibble has a Working Load Limit WLL of 3000kg and a unit weight of 320kg with a capacity f...

Page 3: ...Concrete Kibble with a Forklift ensure that the fork arms are suited to the attachment and set to a width that ensure stability of the load Fig 3 1 type CK10 shown To ensure the Concrete Kibble stays...

Page 4: ...r not in safe working condition A Competent Person shall inspect the lifting slings lifting bar Gate and Handle mechanisms Chute and chains daily to ensure that they are in safe working order The Oper...

Page 5: ...an Industrial Truck East West Engineering Concrete Kibbles shall not be modified in any way which affects the operation or performance except with the prior approval of East West Engineering After any...

Page 6: ...ning in the safe use of the Concrete Kibble shall be undertaken before usage The Crane Operator must not work the Crane unless they are physically and mentally capable This is in accordance with AS 25...

Page 7: ...izontal movement permissible M When landing the Kibble avoid developing rope slack N The Operator must know the location of the main isolation switch and Fire fighting equipment 5 2 Risk Control Measu...

Page 8: ...ade aware of the need to release the concrete gradually from the Kibble to prevent the formwork from being overloaded and risk structural damage I The Kibble Operator MUST be made aware that the sudde...

Page 9: ...60 Long 8 Pouring Chute Sleeve CKM05 16 CKM05 16 CKM05 16 9 Handle Link CKM05 38 CK05 09 CK05 09 10 Washer Flat M20 M20 M20 11 Roll Pin 6 x 40 Long 6 x 40 Long 6 x 40 Long 12 Metric Bolt G8 8 Washer N...

Page 10: ...components are considered worn or damaged or if safety charts or labels are damaged or illegible the Kibble should be taken out of service and East West Engineering or an Authorised Person contacted f...

Page 11: ...vant Australian Standards including those listed below AS NZS 1554 1 2011 Structural Steel Welding Welding of Steel Structures AS 1418 1 2004 Cranes General Requirements AS 2550 1 2011 Cranes Safe Use...

Page 12: ...WE will at its option either repair or replace nonconforming or defective products for which it is responsible or return to buyer their purchase price The foregoing states buyer s exclusive remedy for...

Reviews: