First of all, consider where you are going to place your UV system. You will need to access it to change the 
lamp/quartz sleeve and check on a regular basis that it is working correctly. This includes making sure that it 
has a continuous power supply via the transformer. 

Before you position your unit for installation, make sure that you are not going to affect any existing plumbing 
or electrical supplies. 

Install the mounting clips to a wall or other stable and solid location. 

Install the necessary plumbing required to connect  the stainless steel chamber. 

Ensure that you put 10 

turns of PTFE tape between the stainless steel sleeve and the connectors. 

1. 

Refer to the photographs and instructions on page 3, steps 1 to 6 

2. 

Once the quartz sleeve and lamp have been set up correctly, connect to the water supply and turn on 

 

 the water. Check for leaks and repair if necessary.  

3. 

Plug the transformer into an electrical power supply and switch on 

4. 

Run water through the chamber for 5-10 minutes before use. 

1. 

Disconnect the power supply 

2. 

Turn the water off and open a tap down stream of the system to relieve the pressure 

3. 

Remove the PVC cap and unscrew the aluminium nut 

4. 

Carefully withdraw the lamp approximately 2cm from the chamber 

5. 

While holding the lamp end, carefully remove the lamp socket on the exposed end 

6. 

Carefully withdraw the lamp from the chamber and put to one side for recycling 

7. 

Remove the new lamp from its packaging and without touching the glass of the lamp, connect to the 
socket  (see page 3, sections 2-6) 

8. 

Follow steps 2 to 4 as above—”Installing the Quartz sleeve and UV lamp” 

To ensure maximum efficiency of your UV system, we suggest you carry out the following regular 
maintenance: 



Clean the quartz sleeve every 6-12 months using a glass cleaner 



Replace the quartz sleeve every 24 months 



Replace your UV lamp every 12 months without fail (or your water quality 
may be compromised) 



Ensure that you use reliable components from East Midlands Water Company or a 
recommended reputable supplier 

Getting started 

Installing the Quartz sleeve and UV lamp 

Replacing your UV lamp  

Recommended  maintenance 

Page 2 

Summary of Contents for UV 3.9 LPM

Page 1: ...to your plumbing using the connectors shown or similar Quartz sleeve and lamp HANDLE WITH CARE They are MADE OF FRAGILE GLASS Avoid touching the centre part of the sleeve lamp Pick up and handle by both ends The photograph shows the rubber o ring in place on the sleeve approximately 2cm from the open end The lamp This is filled with special incandescent bearings which when heated fluoresce and are...

Page 2: ...the chamber for 5 10 minutes before use 1 Disconnect the power supply 2 Turn the water off and open a tap down stream of the system to relieve the pressure 3 Remove the PVC cap and unscrew the aluminium nut 4 Carefully withdraw the lamp approximately 2cm from the chamber 5 While holding the lamp end carefully remove the lamp socket on the exposed end 6 Carefully withdraw the lamp from the chamber ...

Page 3: ...GHTEN Now connect the lamp to the socket DO NOT TOUCH THE LAMP WITH BARE HANDS AS THIS WILL AFFECT THE PERFORMANCE OF THE LAMP Connect by gently pushing the four pins of the lamp into the socket Gently position the lamp into the quartz sleeve through the open end of the stainless steel casing Push on the rubber cap seal and ensure that it is sitting correctly with no creases or kinks 2 3 4 6 1 2 3...

Page 4: ... Rubber o ring 6 Quartz sleeve 7 Stainless steel chamber 8 Elbow optional 9 Mounting bracket separate on some units 10 Transformer fitted with standard UK electrical plug Diagram of set up of UV water sterilisation system Page 4 For replacement UV lamps quartz sleeves and transformers please contact www eastmidlandswater com or call us on 0116 276 3334 ...

Reviews: