background image

Ultra Compact Meter     

Controlled Water Softener 

 

 

 

 

1

 

A WARM WELCOME FROM EAST MIDLANDS WATER COMPANY

 

YOU HAVE CHOSEN A QUALITY WATER SOFTENER  AND ONE THAT WILL GIVE YOU 

MANY YEARS OF TROUBLE FREE SERVICE

 

 

PLEASE READ THESE FITTING INSTRUCTIONS 

BEFORE INSTALLATION

 

 

IF YOU PURCHASED A 15mm or 22mm FITTING KIT, THESE ARE 

PACKED INSIDE YOUR SOFTENER

 

Contents of box:

 

 

Your EMWC Ultra 

Compact water 

softener 

 

1/2” 

flexible hose  

for  the overflow 

 

Instructions for installation

 

 Your  warranty details are stored digitally 

 

transformer

 

 

Plus a fitting kit (if purchased) 

CHECK INSIDE YOUR 

SOFTENER AS THIS IS 

WHERE IT WILL BE 

PACKED

 

 

Blue 

3/8” 

waste hose 

and push fit connector

 

Summary of Contents for Ultra Compact

Page 1: ...INSTRUCTIONS BEFORE INSTALLATION IF YOU PURCHASED A 15mm or 22mm FITTING KIT THESE ARE PACKED INSIDE YOUR SOFTENER Contents of box Your EMWC Ultra Compact water softener 1 2 flexible hose for the overflow Instructions for installation Your warranty details are stored digitally transformer Plus a fitting kit if purchased CHECK INSIDE YOUR SOFTENER AS THIS IS WHERE IT WILL BE PACKED Blue 3 8 waste h...

Page 2: ...cess water is drawn from the brine tank and flushed through the system At the end of the cycle water is put back into the brine tank in order for the salt to dissolve ready for the next time the machine needs to regenerate On some units this is delayed until a few hours before regeneration The level of water in the tank will depend on the type size and water pressure feeding the softener Dependent...

Page 3: ...short as possible Ensure that both the drain and overflow are not subject to excessive temperatures freezing or over 120 F If you are siting the softener in a cupboard ensure that the base of the cupboard is adequately supported If the softener is being installed in a loft it is recommended that you house the softener within a well insulated 25 gallon tank The overflow on the tank should be below ...

Page 4: ...an run up hill to a maximum of 3 feet with a minimum pressure of 40psi Softened water will have no adverse effect on a septic tank Overflow Connection The overflow connection is the white hose spigot on the rear or side of the cabinet No clip is required for this connection The overflow must be run downhill through an outside wall without kinks or restriction It is recommend the overflow hose be v...

Page 5: ... at this stage to allow you to confirm that the unit has no leaks from the installed valves and the waste runs free This regeneration will also assist in clearing any potential air locks that may be present within the system The regeneration will also reset any internal meter or timer devices that dictate the frequency of the regeneration cycle It is important that you have your softener regularly...

Page 6: ...nual regeneration Press and hold the controller 1 for three seconds This will initiate an immediate regeneration The display will show a cascading symbol as it cycles to backwash The unit will proceed through a complete regeneration Delayed regeneration If you need to set up a delayed regeneration follow these steps Press and release the regeneration controller 1 The unit will regenerate at the ne...

Reviews: