![East Coast Datacom Nx8- Dual Composite MUX High-Speed 16-Port TDM Multiplexer Operation Manual Download Page 67](http://html1.mh-extra.com/html/east-coast-datacom/nx8-dual-composite-mux-high-speed-16-port-tdm-multiplexer/nx8-dual-composite-mux-high-speed-16-port-tdm-multiplexer_operation-manual_522169067.webp)
166119
8/31/2006
63
5.3 Adapter Cables
5.3.1 Composite Port V.35 Adapter Cable Connection Diagram
Use the following diagram when constructing or specifying an adapter cable between the
Nx8-DualMUX Composite port and a standard V.35 cable, or DCE device.
V.35 mode
25-pin Female
Sub-miniature D
V.35
34-pin Male
M-Block
Signal
Pin
Pin
Signal
TXD+
2
\
<><><><><><><><><> Twisted Pair <><><><><><><><>
/
P
SD+
TXD-
14
/
\
S
SD-
RXD+
3
\
<><><><><><><><><> Twisted Pair <><><><><><><><>
/
R
RD+
RXD-
16
/
\
T
RD-
TXC+
15
\
<><><><><><><><><> Twisted Pair <><><><><><><><>
/
Y
SCT+
TXC-
12
/
\
AA
SCT-
RXC+
17
\
<><><><><><><><><> Twisted Pair <><><><><><><><>
/
V
SCR+
RXC-
9
/
\
X
SCR-
TXCE+
24
\
<><><><><><><><><> Twisted Pair <><><><><><><><>
/
U
SCTE+
TXCE-
11
/
\
W
SCTE-
RTS
4
-
=============================================
-
C
RTS
CTS
5
-
=============================================
-
D
CTS
DSR
6
-
=============================================
-
E
DSR
CD
8
-
=============================================
-
F
RLSD
DTR
20
-
=============================================
-
H
DTR
Ground
7
-
=============================================
-
B
Ground
Shield
1
-
=============================================
-
A
Shield
Table 18 - Composite Port to V.35 Adapter