F1-2 displays the status and gain required by each
channel to maximize the signal strength (a lower
number indicates a strong signal). Typical values for the
velocity sensors will be between 650 and 850. Gain
values for the height sensor should be between 300 and
400. The temperature and fluid level as monitored by
the level sensor will also be displayed.
F1-2
38
ACCURON CARTRIDGE METER
SERIES 7200
F1-1 displays phase shift in degrees, transit time in
milliseconds, velocity in feet per second, the measured
distance from the level sensor to the fluid, and the
calculated level of the water, in user selectable units (see
OPTIONS section), above the 0 flow point of the channel.
F1-1
Press the ENTER key to cycle to the next status
page (F1-3). Cycling through all of the status pages
will return you to the main screen.
Press the ENTER key to cycle to the next status
page (F1-2). Cycling through all of the status pages
will return you to the main screen.