P08
High-
pressure 2
protection
High pressure
switch 2 cuts
Check if high pressure
switch 2 cuts under
unit OFF condition
Change high pressure
switch 2
E01
Controller
communi-
cation
failure
Communica
tion cable
cuts
Check
communication
cable if cut
Change connection
cable or re-connect
E02
TP1 exhaust
gas tempe-
rature sensor
failure
sensor tempera-
ture deviation
or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E03
T3 coil tem-
perature
sensor
failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E04
T4 ambient
temperature
sensor
failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E05
T5 liquid
gas
temperature
sensor
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E06
TH return
gas
temperature
sensor
failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E07
TW water
tank
temperature
sensor failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E08
T6 inlet water
temperature
sensor failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E09
T7 outlet wa-
ter tempera-
ture sensor
failure
sensor
temperature
deviation or cuts
Check sensor
resistance value or if
sensor cuts
Change sensor or re-
connect cable
E10
Controller
and Drive
PCB
Communi-
cate failure
Communication
cable cuts
Check communication
cable if cut
Change connection
cable or re-connect
V.1
18
Summary of Contents for EBP08WZRN
Page 26: ...Modelo EBP23WZRN V 1 25 ...
Page 27: ...EBP29WZRN V 1 26 ...
Page 28: ...Modelo EBP34YZRN V 1 27 ...
Page 33: ...APLICACIÓN WI FI BOMBA DE CALOR INVERTER PARA PISCINA Serie EBP MANUAL DE INSTRUCCIONES V 1 ...
Page 68: ...Modelo EBP08WZRN EBP12WZRN EBP015WZRN V 1 23 ...
Page 69: ...Modelo EBP23WZRN V 1 24 ...
Page 70: ...EBP29WZRN V 1 25 ...
Page 71: ...EBP34YZRN V 1 26 ...
Page 76: ...Pool Comfort WI FI APP INVERTER SWIMMING POOL HEAT PUMP EBP Series INSTRUCTION MANUAL V 1 ...
Page 85: ...5 App operation Modify button Click it to enter the modify interface V 1 10 ...