E T X S E R I E S L I T H I U M B A T T E R I E S
6
Dimensions
5.9in x 3.4in x 4.5in
(150mmX86mmX115mm)
Environmental Rating (resistance to
water intrusion)
IP 66 (wash down with a high-pressure
washer)
Operating Temperature
-30 °C to +60 °C
Storage Temperature
-40 °C to +70 °C
Model: ETX12A, ETX12B (ETX12B discontinued as of 4-2016, use ETX12A as
replacement)
Voltage
13.2 V
Ah (Lead-acid equivalent)
12
Ah (1 hour discharge rate)
4 (1C rate)
Pulse Crank Amps (PCA)
220A (3 sec @ 20 °C, voltage >7.2V)
Cold Crank Amps (CCA)
135A (modified SAE test, 3 sec@ 0°F,
voltage >7.2V)
Max Continuous Discharge Amps
40A
Standard Charge Voltage
13.9 - 14.6 V
Recommended Charger/Maintainer
Amps
.8 - 5A
Max Charge Amps
20A (from vehicle charging system)
Life (Charge cycles)
4000 cycles @ 1C discharge rate, 25
°
C
(20% depth of discharge)
2000 cycles @10C discharge rate, 25
°
C
(80% depth of discharge)
Life (Years)
8 Years
Weight
1.3 lb. (.6Kg)
Dimensions
ETX12A
4.5in x 2.6in x 3.7in
(113mmX66mmX95mm)
ETX12B
5.3in x 2.6in x 4.1in
(135mmX66mmX105mm)
Environmental Rating (resistance to
water intrusion)
IP 66 (wash down with a high-pressure
washer)
Operating Temperature
-30 °C to +60 °C
Storage Temperature
-40 °C to +70 °C
Model: ETX18B, ETX18C, ETX18F
Voltage
13.2 V
Ah (Lead-acid equivalent)
18
Ah (1 hour discharge rate)
6.2 (1C rate)
Pulse Crank Amps (PCA)
340A (3 sec @ 20 °C, voltage >7.2V)
Cold Crank Amps (CCA)
230A (modified SAE test, 3 sec@ 0°F,
voltage >7.2V)
Max Continuous Discharge Amps
60A
Standard Charge Voltage
13.9 - 14.6 V