12. 

Next push lever forward to setting 

“0”.  

Align control rod 

with hole in pivot bracket, pull lever backward to insert control 
rod through hole in  pivot bracket.  

[T

IP

If the lever does not 

move easily, loosen slightly to make this step easier] 

Now install 1/4-20 regular nut on to Control rod.   

DO NOT TIGHTEN NUTS YET.

           

11. 

I

nstall flattened end of control rod in to lever on gauge into Control 

Rod Tabbed hole as shown. Turn to lock in place.   

N

EXT

Install (1) 1/4-20 Regular Nut 

[not a locknut] 

on to Control Rod and 

thread halfway as shown to the left. 

13. 

Pull  lever  back  to  setting  

“30” 

as shown.  Next push pivot & 

bracket forward so that the shut off plate in the hopper is in the full open 
position. 

[N

OTE

: T

HE

 S

ETTING

 

OF

 “30” 

ON

 

THE

 G

AUGE

 & L

EVER

 A

S-

SEMBLY

 

MUST

 

OPEN

 

THE

 S

HUT

-

OFF

 

COMPLETELY

 

FOR

 

PROPER

 

CALIBRA-

TION

.]  

Now tighten the nuts against the pivot bracket to prevent change 

in calibration.  Test by opening and closing the Gauge & Lever a few 
times to ensure an accurate calibration. 

14

Insert Agitator to pinion shaft on inside of hopper.  

N

OTE

:  

Position of flat side of agitator.  This pin should be 

installed as shown. 

PAGE 4 

15. 

Tension on the flow control lever may be adjusted by 

tightening or loosening the tension nut as shown on the right. 

10. 

Install handle shaft to lower handles and pivot & bracket assembly 

as shown.  Using (4) 1 ½” bolts and (4) locknuts.  

[T

IP

Attach right 

side first, then attach left (Pivot Bracket) side] 

T

IGHTEN

 

BOLTS

 

AND

 

NUTS

 

NOW