background image

EARTHSTONE OVENS PRE-ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 

 

      

       4 

 

 

WOOD AD/OR GAS FIRED COMBIATIO PIZZA OVE 

OPERATIG ISTRUCTIOS 

 

WARNING

 
READ ALL INSTRUCTIONS CAREFULLY.  IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE 
OR PERSONAL INJURY.  INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING 
AND SUPERVISING PERSONNEL.  WATCH TRAINING VIDEO FOR VISUAL OPERATION INSTRUCTIONS. 
 
THIS OVEN IS INTENDED FOR ATTENDED OPERATION BY TRAINED AND QUALIFIED PERSONNEL ONLY. 
 
THIS OVEN IS A HEAT PRODUCING APPLIANCE AND MAY CAUSE SEVERE BURNS IF TOUCHED. 
 

 

 
DO  NOT  OVER  FIRE.    IF  FLAME  SPILLS  FROM  THE  DOOR  OPENING  OR  OVEN  TEMPERATURE  EXCEEDS  1000 
DEGREES FAHRENHEIT, YOU ARE OVER FIRING. 
 
THIS UNIT IS DESIGNED AS A GAS OR GAS/WOOD FIRED OVEN. DIRECT FOOD CONTACT WITH THE HEARTH IS 
RESTRICTED  TO  PIZZAS  AND  BREAD  PRODUCTS  ONLY.    FOR  OTHER  FOODS  REFER  TO  MANUFACTURE 
OPERATION  GUIDELINES.   

ALL  WOOD  EMBERS  BURNED  INSIDE  THE  OVEN  MUST  BE  PLACED  DIRECTLY  ON 

THE OPPOSITE SIDE OF THE GAS BURNER (SEE DIAGRAM).  WOOD SHOULD BE USED ONLY FOR FLAVORING 
AND AESTHETIC VALUE, THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER 

 
KEEP A PROPER FIRE EXTINGUISHER CLOSE TO THE OVEN AT ALL TIMES.  EXTINGUISHER MUST BE RATED 
FOR  USE  ON  WOOD  FIRES.    INSTRUCT  ALL  PERSONNEL  ABOUT  LOCATION  AND  USE  OF  THE  FIRE 
EXTINGUISHER AND PROPER FIRE EMERGENCY PROCEDURES. 
 
a- 

Before starting, turn "ON" exhaust fan and make-up air blowers. 

 
b- 

Place a small amount of wood and kindling on the hearth over a fire-starter block.  Light fire- 

 

 

starter.  At any time do not use more than four pieces of wood, 

 
c- 

CAUTION:  NEVER USE GASOLINE TYPE LANTERN FUEL, KEROSENE, CHARCOAL   

 

LIGHTER FLUID OR SIMILAR PRODUCTS TO START OR "FRESHEN UP" A FIRE IN THIS  

 

 

OVEN. KEEP ALL SUCH LIQUIDS WELL AWAY FROM THE OVEN WHEN IN USE. 

 

d.

 

When the kindling is burning well, add larger pieces of firewood.  USE WELL-SEASONED OR  

 

DRIED WOOD ONLY. 

 
e- 

Continue to add fuel as needed to maintain the desired heated rate, being careful to never  

 

 

over fire the unit. 

 
f- 

Whenever fuel is added, the fire may be poked and stirred with a wood handling tool.  This will  

 

 

allow air to move through the fuel bed for proper combustion. 

 
 

Summary of Contents for 130-PAGW

Page 1: ...PROMINENT LOCATION FOR YOUR SAFETY DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WAR I G IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLATION OR SERVICING THIS EQUIPMENT A CAUSE OF OVEN...

Page 2: ...AGRAM IS LOCATED ON THE CONTROL BOX INSTALLATION MUST CONFORM WITH LOCAL CODES OR IN THE ABSENCE OF LOCAL CODES WITH THE NATIONAL FUEL GAS CODE ANSI Z223 1 THE NATURAL GAS INSTALLATION CODE CAN CGA B149 1 OR THE PROPANE INSTALLATION CODE CAN CGA 149 2 AS APPLICABLE INCLUDING 1 THE APPLIANCE AND ITS INDIVIDUAL SHUT OFF VALVE MUST BE DISCONNECTED FROM THE GAS SUPPLY PIPING SYSTEM DURING ANY PRESSURE...

Page 3: ...NSTRUCTIONS CAREFULLY IMPROPER USE OF THIS APPLIANCE MAY RESULT IN A BUILDING FIRE OR PERSONAL INJURY INSTRUCTIONS MUST BE READ AND THOROUGHLY UNDERSTOOD BY ALL OPERATING AND SUPERVISING PERSONNEL WATCH TRAINING VIDEO FOR VISUAL OPERATION INSTRUCTIONS THIS OVEN IS INTENDED FOR ATTENDED OPERATION BY TRAINED AND QUALIFIED PERSONNEL ONLY THIS OVEN IS A HEAT PRODUCING APPLIANCE AND MAY CAUSE SEVERE BU...

Page 4: ...ITE SIDE OF THE GAS BURNER SEE DIAGRAM WOOD SHOULD BE USED ONLY FOR FLAVORING AND AESTHETIC VALUE THE MAIN SOURCE OF HEAT SHOULD BE SUPPLIED BY THE GAS BURNER KEEP A PROPER FIRE EXTINGUISHER CLOSE TO THE OVEN AT ALL TIMES EXTINGUISHER MUST BE RATED FOR USE ON WOOD FIRES INSTRUCT ALL PERSONNEL ABOUT LOCATION AND USE OF THE FIRE EXTINGUISHER AND PROPER FIRE EMERGENCY PROCEDURES a Before starting tur...

Page 5: ...od container closed at all times when not adding or removing firewood Keep container a considerable distance from the oven and far away from sources of heat or ignition DO NOT store matches paper or other easily ignited items with firewood 5 Provisions must be made to supply sufficient combustion air into the structure when using this appliance Combustion air must be supplied in accordance with lo...

Page 6: ...nced chimney and duct servicing personnel who are qualified in the removal of both creosote and grease from flues and ducts should be contracted to do the inspection and cleaning The inspection and cleaning schedule must be adjusted as needed to prevent the buildup of creosote and or grease More frequent inspections and cleanings are indicated when excessive buildup occurs between regular inspecti...

Page 7: ...BURNER FOR CLEANING FOLLOW THESE STEPS DISCONNECT CABLE FROM SPARK IGNITER UNSCREW FITTING OF GAS SUPPLY LINE WHICH IS NEAREST TO BURNER ASSEMBLY THIS SUPPLY LINE CONNECTS THE GAS VALVE TO BURNER ASSEMBLY TILT OPPOSITE END OF BURNER UP AND SLIDE BURNER DOWN FROM BURNER ENCLOSURE CLEAN BURNER WITH WIRE BRUSH TO ENSURE THAT ALL THE JET HOLES ARE CLEAN 4 TO REPLACE BURNER AFTER CLEANING FOLLOW THESE ...

Page 8: ...E OR COUNTER CLOCKWISE 5 RED BUTTO USED SIMULTANEOUSLY WITH BLACK DIAL KNOB TO SET TEMPERATURE SEE PAGE LABELED SWITCH DIAGRAM LAYOUT OPERATION FIRI G OVE OTE DO OT CLOSE DOOR WHILE OVE IS BEI G FIRED MAKE SURE GAS CONTROL VALVE IS IN THE ON POSITION WHILE PRESSING RED BUTTON TURN BLACK KNOB TO DESIRED TEMPERATURE THIS SHOULD BE ABOUT 650 F TO 750 F MOVE SWITCH TO HI LOW POSITION TURN MAIN POWER S...

Page 9: ... USE ANY CLEANING AGENTS IN THE OVEN SHUTTI G DOW OVE TURN MAIN POWER SWITCH TO OFF POSITION IF OVEN IS BEING SHUT DOWN FOR THE NIGHT GAS CONTROL VALVE SHOULD BE TURNED TO OFF POSITION SAVE THESE I STRUCTIO S IF YOU HAVE ANY QUESTIONS PLEASE CALL 800 840 4915 or 818 553 1134 ...

Page 10: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 10 GAS BURNER CONTROLS E S ARTH TONE LOS ANGELES OFF ON HI LO HI OFF 000 1 2 3 4 5 ...

Page 11: ...ven may cause negative pressure servicing proper operation If this area is to be covered with a facade it must be of a non combustable material Temperature gauge and On off switch can be extended to attach over facade 1 inch minimum clearance to combustibles Facade Flue Collar Models 90 and 110 6 inch diameter Models 130 and 160 8 inch diameter Any adjacent combustible floor which projects in fron...

Page 12: ...NSTALLATION INSTRUCTIONS 12 GAS BURNER WOOD All wood fired in a gas wood combination o ven should be located on the opposite side of the gas bu rner Take caution to avoid ashes from entering the gas burner cavity E S ARTH TONE WOOD FIRE OVENS ...

Page 13: ...EARTHSTONE OVENS PRE ASSEMBLED GAS OVEN INSTALLATION INSTRUCTIONS 13 LOG CONFIGURATION TOP VIEW SIDE VIEW LOG 1 1 LOG HAS A NOTCH TO SUPPORT LOG FROM ROLLING OFF LOWER SUPPORT LOG ...

Page 14: ...4 opening needed for combustion air Only one intake should be installed located in the front or back of oven Gas Burner system Air flow Roof False Ceiling Air flow Air flow 24 x24 opening needed for combustion air Only one intake should be Gas Burner system Air flow Improper Installation 1 No air intake opening for burner Roof Ceiling Air flow Air flow Air flow Blocked air intake In this case a 24...

Page 15: ...ssure below where the gas burner is located The air underneath will travel towards the air flow above creating a suction which will force the gas flame downwards To prevent this a non combustable lid must be placed above the oven 3 Altered air flow from air intake in a separate room with low pressure Roof Ceiling Air flow Air flow Air Intake Air Intake Air flow Air flow to oven is altered as air m...

Page 16: ...TER CLOCKWISE TO DECREASE AND CLOCKWISE TO INCREASE REMOVE OVE DOOR THE DOOR SHOULD OT BE CLOSED WHE OVE IS FIRED WITH A 2 SIDED OVE YOU CA HAVE O E DOOR CLOSED MOVE HI LO HI OFF SWITCH TO HI LO UPWARD CLICK TURN ON OFF SWITCH TO ON INITIALLY OVEN MAY NEED TO BE TURNED ON AND OFF 4 OR 5 TIMES IN 1 SECOND INTERVALS IN ORDER TO BLEED THE GAS PIPE CLICK ON WAIT 1 SEC TURN OFF CLICK ON WAIT 1 SEC TURN...

Page 17: ...ld Pressure The amounts listed below are set at the factory Natural Gas Manifold pressure 90 PAGW 4 W C 110 PAGW 4 W C 130 PAGW 4 5 W C 160 PAGW 4 5 W C LP Gas Manifold pressure 90 PAGW 7 W C 110 PAGW 7 W C 130 PAGW 7 W C 160 PAGW 7 W C The inlet and manifold outlet pressure taps are located at the Gas Control Valve This part is in the burner controls box and attached to the oven support stand ...

Reviews: