EARTHSTONE OVENS PRE-ASSEMBLED INSTALLATION INSTRUCTIONS---
6
FOR COMMERCIAL US E ONLY
Figur e 2
U.M.C. & N.F.P.A.
Figure 1
COMBUSTIBLES
3"MIN.
1" MI N.
105" MIN.
COMBUSTIBLES
3"MIN.
F EED
OPENING
COMBUST IBLES
1"
MIN .
1"MIN.
1"MIN .
48"
MIN.
48"
MIN.
Figure 4
ALL CLEARANCES SPECIFIED ARE
THE MINIMUM REQUIRED AIR SPACES
WARNING: DO NOT PACK REQU IRED AIR SPACES
WITH INSULATION OR OTHER M ATERIALS.
Any adjacent combustible floor which projects
in front of the oven opening must be a minimum
of 30 inches away from each side of the door
opening and 36 inches from the front of the
door opening. See Page 14 for more information
FOR COMMERCIAL USE ONLY
Figur e 3
U.M.C. & N.F.P.A.
Outside Dimensi
on
MODEL 90-Due' - (A) 60" x (B) 44"
MODEL 110-Due’ - (A) 92.25” X (B) 54.25”
MODEL 130-Due’ - (A) 116.25 X (B) 66.25”