SCW-410-QS (05/12)
Page 6
•
Where the total length of refrigerant line sets (from manifolds to compressor unit and from
compressor unit to air handler) do not exceed 125 feet, as shown in Figure 2a.
•
Where the compressor unit is no more than 20 feet higher than the earth loop manifolds.
Compressor unit may be located lower than the earth loop manifolds. See Figure 2a.
•
For SCW compressor units providing radiant panel hydronic hot water or chilled water, where
the hydronic primary circuit is adequately protected from freezing by providing adequate site-
specific antifreeze protection for the water circulating system.
Figure 3. Compressor Unit Bracket Installation
Figure 4. Compressor Unit Clearance