
Isokern Maximus Linear Rating Plate ...........................2
General Information ..................................................... 3
Safety Instructions .................................................... 4-5
Maximus Linear 82L48 Drawings .................................6
Maximus Linear 82L48 Components ...........................7
Maximus Linear 82L72 Drawings .................................8
Maximus Linear 82L72 Components ...........................9
Maximus Linear 82L96 Drawings ...............................10
Maximus Linear 82L96 Components ......................... 11
Maximus Linear 82L120 Drawings .............................12
Maximus Linear 82L120 Components ........................13
Required Clearance to Combustibles .........................14
Calculating Flooring Loads ..........................................15
Rough Framing Dimensions .......................................16
General Assembly Instructions ...................................17
Maximus Linear Assembly Instructions .................18-22
Assembled Linear Units ........................................23-24
Access Modification ...................................................25
B-Vent Metal Chimney - General Information .............26
B-Vent Metal Chimney & Components ......................27
B-Vent Metal Chimney Installation ........................28-29
Enervex RS Chimney Fan & MFD Components .........30
Enervex RS Chimney Fan & MFD - General Information .....30
2
Earthcore Industries
Isokern Maximus Linear Series Gas Fireplace
01/2020
Table of Contents
Enervex MFD - General Information ...........................31
Enervex RS Chimney Fan - General Information ........32
Enervex MFD & RS Chimney Fan - Installation
Instructions ..........................................................33
Enervex MFD & RS Chimney Fan - Wiring Diagram ...34
Firebrick Installation ...............................................35-36
Flush Wall Finish Detail ...............................................37
Clearance to Combustible Trim ...................................38
Isoflames Linear Burner - Safety Instructions ........39-40
Isoflames Liner Burner Rating Plate ...........................41
Isoflames Linear Burner - Components List ...............42
Isoflames Linear Burner - Specifications ....................43
Gas Line & Valve Box Installation ................................44
Valve Box & Burner Wiring Diagram ...........................45
Burner Installation .................................................46-47
Burner Component Connection .............................48-50
Burner Lighting Instructions .......................................51
Remote Control System ........................................52-53
Troubleshooting ..........................................................54
Glass Media Options ..................................................55
Optional Log Sets .......................................................56
Warranty Card .............................................................57
Warranty & Disclaimer ................................................58
ISOKERN LINEAR GAS FIREPLACE
LISTED VENTED GAS FIREPLACE PER ANSI Z21.50 - 2019
CSA 2.22-2019
NOT FOR USE WITH SOLID FUEL
FOR USE WITH PROPANE (LP) OR NATURAL GAS, SEE GAS IDENTIFYING TAG ON BURNER
82L48 NATURAL GAS MAX BTU 54,000; PROPANE MAX BTU 48,000
82L72 NATURAL GAS MAX BTU 92,000; PROPANE MAX BTU 80,000
82L96 NATURAL GAS MAX BTU 108,000; PROPANE MAX BTU 96,000
82L120 NATURAL GAS MAX BTU 110,000; PROPANE MAX BTU 105,000
*See Burner Rating Plate For Additional Information
MANIFOLD PRESSURE: PROPANE (LP): 10" WATER COLUMN; NATURAL GAS: 3.5" WATER COLUMN
MINIMUM PERMISSIBLE GAS SUPPLY PRESSURE FOR PURPOSE OF INPUT ADJUSTMENT:
PROPANE (LP): 11" WATER COLUMN; NATURAL GAS: 5" WATER COLUMN
CAUTION: THIS APPLIANCE IS ONLY FOR USE WITH THE TYPE OF GAS INDICATED ON THE RATING PLATE AND MAY BE INSTALLED IN
THE AFTER-MARKET, PERMANENTLY LOCATED, MANUFACTURED HOME (USA ONLY) OR MOBILE HOME, WHERE NOT PROHIBITED BY
LOCAL CODES. SEE OWNER’S MANUAL FOR DETAILS. THIS APPLIANCE IS NOT CONVERTIBLE FOR USE WITH OTHER GASES, UNLESS A
CERTIFIED KIT IS USED.
”
This appliance must be installed in accordance with local codes, if any, if none, follow the current ANSI Z223.1/NFPA 54 or
CSA B149.1
ELECTRICAL RATING:
UNIT: ELECTRONIC
1 PH
60 HZ
120 VOLTS
LESS THAN 5 AMPS
SERIAL NO:
L000001
CLEARANCE TO COMBUSTIBLES:
UNIT FRONT
= 0in
UNIT SIDES AND REAR
= 1.5in.
COMBUSTIBLE SHEATHING ABOVE OPENING TOP
=
8
in
SHEATHING OR TRIM TO OPENING SIDES
=
8
in
MANTLE ABOVE OPENING
= 12in.
= 12in
INSULATION FROM FIREBOX
= 3in.
= 3in
MADE IN THE USA
CHESAPEAKE, VA 23323
82L48
82L72
MODEL #
82L120
PFS REPORT NO. F19 - 161
ISOKERN LINEAR FIREPLACE RATING PLATE
EARTHCORE INDUSTRIES HEADQUARTERS
JACKSONVILLE, FL 32256
82L96
= 0in
= 0in
Open Front
Only
Glass Front
Only
= 0in
= 1.5in.
Rating Plate