2

CHIMNEY DIAMETER:

Follow  the  fireplace  manufacturer’s  manual  to 

determine required chimney diameter and clearances 

between  combustible  materials  and  your  fireplace. 

Never use a chimney with an inside diameter smaller 

than  your  firebox  flue  opening  unless  specifically 

allowed by the fireplace manufacturer. 

CHIMNEY ENCLOSURE REQUIREMENTS:

Interior chimneys shall be enclosed where they 
extend through closets, storage areas, occupied 
spaces, or anywhere the surface of the chimney could 
be contacted by persons or combustible materials. 
The air space between the outer wall of the chimney 
and the enclosure shall not be less than 2 inches.

WARNING:  Do not place any type of insulation or 

other  materials  in  the  required  clearance  spaces 

surrounding the chimney assembly.

Except for installation in one or two family dwellings, 
a factory built chimney that extends through any 

zone above that on which the connected appliance is 

located is to be provided with an enclosure having a 

fire resistance rating equal to or greater than that of 

the floor or roof assemblies through which it passes.

In cold climates, chimneys mounted on an outside wall 
should be enclosed in a chase. Exterior chases reduce 
condensation, creosote formation and enhance draft.

Chimney components intended for exterior 

installation must be marked “

Suitable for Interior or 

Exterior Installation

”.

INSTALLATION RECOMMENDATIONS:

Proper planning for your EC

O

-Steel Air-Cooled and 

Insulated Chimney installation will result in greater 

safety,  efficiency  and  convenience.  You  must  use 

only EC

O

-Steel Chimney parts and components 

to maintain a listed chimney system. Do not mix 
EC

O

-Steel Air-Cooled and EC

O

-Steel Insulated 

Chimney parts or try to match with other products or 
use improvised solutions.

Install  your  fireplace  as  described  by  the 

manufacturer’s installation instructions and maintain 

all required clearances.  Acceptance of the assembly 

is void if the installation instructions are not followed.

Connect only one fireplace per chimney. Follow the 

fireplace safety manual for maximum efficiency and 

safety. Do not over fire. Any damage to the fireplace 

or chimney can possibly void the warranty.

Do not burn driftwood, plastic, or chemically treated 
wood such as railroad ties. They are corrosive to your 

chimney system. Follow the fireplace manufacturer’s 

instructions regarding fuel.

ISOKERN FIREPLACE INSTALLATION:

Place Fireplace:

  Position  according  to  the  fireplace 

manufacturer’s installation instructions. The flue outlet 

should be placed between the rafters or joists above, 
if possible. 

Determine Chimney Size:

  Follow  the  fireplace 

manufacturer’s instructions for chimney size. 

Mount Anchor Plate:

 Chimneys for Isokern fireplaces 

with  EC

O

-Steel begin with an Anchor Plate or Anchor 

Plate with Damper. 

It is important that the surface of the Isokern chimney 

has a level surface on which to attach the Anchor Plate. 

If the top of the Isokern does not have a level surface, 

then  it  will  need  to  be  modified  accordingly.  Center 

the  Isowool  blanket  over  Isokern  Top  Plate  hole  and 

trace outline of hole with a pen or marker. Cut a hole in 

the blanket to match the hole in the Isokern top plate. 

Center the Isowool blanket over the Isokern Top Plate 

flue opening, then center anchor plate over the Isowool 

blanket.    If  a  Damper  is  used,  make  sure  nothing 

interferes with the damper plate movement.  Secure 
the Anchor Plate with four (4) masonry anchors. See 

FIG.1

.  If the Anchor Plate with Damper is installed the 

damper should swing freely.  When the chain is pulled 

down,  the  damper  should  close  (horizontal  position).  

When the chain is released (no weight on the chain), 
the damper should swing open (vertical position).  To 

install  the  lintel  hook,  place  the  damper  plate  in  the 

closed (horizontal) position.  Determine and mark the 

position of the lintel hook.  The lintel hook should be 

mounted in a position so as to provide  a small amount 
of tension in the spring attached to the chain.  See 

FIG. 1

.  The tension is needed to prevent the damper 

plate from rattling when closed.  Mount the lintel hook 

to masonry with the screws provided.  Do not obstruct 
openings in the anchor plate.

Warning:  Do not locate Anchor Plate with Damper  in 

a location inaccessible for inspection, cleaning and 

servicing after installation.

  

2

FIG. 1

ANCHOR PLATE

ISOKERN-
FIREPLACE

LINTEL 

HOOK

MASONRY

ANCHORS

ISOWOOL BLANKET

Summary of Contents for ECO-Steel

Page 1: ...th exception of the top portion of the chimney cap can be painted with a high temperature rust proof paint Wash the metal surface with a vinegar and water solution to remove any residue before painting Painting the chimney will help to increase chimney life Earthcore assumes no liability for structural damage or roof contamination as the result of creosote formation It is the owner s responsibilit...

Page 2: ...nd safety Do not over fire Any damage to the fireplace or chimney can possibly void the warranty Do not burn driftwood plastic or chemically treated wood such as railroad ties They are corrosive to your chimney system Follow the fireplace manufacturer s instructions regarding fuel ISOKERN FIREPLACE INSTALLATION Place Fireplace Position according to the fireplace manufacturer s installation instruc...

Page 3: ...9 5 AttachChimney Attachthefirstsectionofchimney on the Anchor Plate The joint assembly is a male to female slip fit and held together with button lock tabs See FIG 2 Maintain a 2 inch clearance to combustibles Do not fill the clearance space with any materials If an offset is required refer to Elbow Offset Installation Section CAP STORM COLLAR FLASHING ATTIC INSULATION SHIELD FIRESTOP CHIMNEY ANC...

Page 4: ... Supports which will support 30 feet of chimney FIG 5 Slide the Angle Support around the chimney and align over framed opening Secure to casing with 4 sheet metal screws and assemble brackets per FIG 6 Nail the brackets to the framing using a minimum of 2 nails or screws per bracket A Support Band may be required by some fireplace manufacturers to keep the chimney vertical and help maintain cleara...

Page 5: ...osure Always maintain a 2 air space clearance to combustibles Install the shield as follows Remove any insulation or debris from attic floor around the framed opening Assemble chimney sections above the Firestop to a height that extends beyond the height of the attic insulation shield Slip the Attic Insulation Shield over the chimney until the base sits squarely on the framed opening Secure the At...

Page 6: ...et chart add chimney sections between elbows total pipe length not to exceed 96 inches A Support Band or plumbers strap is required for every 4 foot interval between elbows to support the load as shown in FIG 12 Attach the upper elbow to bring the chimney back to vertical See TABLE 2 and FIG 13 for offset combinations FIG 13 FIG 12 TABLE 2 PLUMBER S STRAP SUPPORT BAND FIRESTOP W RADIATION SHIELD E...

Page 7: ...his transaction and shall not apply 2 The sole and exclusive remedy against Earthcore shall be for the repair or replacement of defective parts as provided herein above NO OTHER REMEDY Including but not limited to incidental or consequential loss shall be available The sole purpose of the stipulated exclusive remedy provided for herein shall be the repair and replacement of defective parts in the ...

Page 8: ...ECO36 36 Pipe 13ACECO48 13INECO48 48 Pipe 13ACECOAP 13INECOAP Anchor Plate 13ACECOAPD 13INECOAPD Anchor Plate w In Line Damper 13ACECOCC Chimney Cap 13ACECO15OS 13INECO15OS 15 Degree Elbow 13ACECO30OS 13INECO30OS 30 Degree Elbow 13ACECOWB Wall Band 2017 Earthcore Industries L L C Form No L2809 08 17 9670 13ACECOFS Firestop Assembly 13ACECOIS Insulation Shield 13ACECOFT Tall Cone Flashing 13ACECOFC...