background image

   

                         

 

 Introduction

 

    

                         

 

 

P

ELLET

  

Q

UALITY

:

Pellet

 

quality

 

is

 

important,

 

please

 

read

 

the

 

following:

Your

 

pellet

 

stove

 

has

 

been

 

designed

 

to

 

burn

 

wood

 

pellets

 

only.

 

Do

 

not

 

use

 

any

 

other

 

type

 

of 

fuel,

 

as

 

this

 

will

 

void

 

any

 

warranties

 

stated

 

in

 

this

 

manual.

The

 

performance

 

of

 

your

 

pellet

 

stove

 

is

 

greatly

 

affected

 

by

 

the

 

type

 

and

 

quality

 

of

 

wood

 

pellets 

being

 

burned.

 

As

 

the

 

heat

 

output

 

of

 

various

 

quality

 

wood

 

pellets

 

differs,

 

so

 

will

 

the 

performance

 

and

 

heat

 

output

 

of

 

the

 

pellet

 

stove.

CAUTION:

 

It is important to select and use only pellets that are dry and free of dirt or any impurities such 

as high salt content. Dirty fuel will adversely affect the operation and performance of the unit and will void 
the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for wood pellet manufacturers. 
We recommend the use of pellets that meet or exceed these standards. Please use a recommended pellet 
type.

P.F.I.

 

PELLET

 

STANDARDS:

Fines (fine particles)......1% maximum through a 1/8” screen
Bulk Density..................40 pound per cubic foot minimum 

Size..............................1⁄4” to 5/16” diameter 1⁄2 – 11⁄2” long maximum Ash 

Content..................1% maximum (Premium grade)

..................3% maximum (Standard grade) 

Moisture Content...........8% maximum
Heat Content.................approximately 8200 Btu per pound minimum

ASH

: The ash content of the fuel and operation of your stove will directly determine the frequency of 

cleaning.  The use of high ash fuels may result in the stove needing to be cleaned daily.  A low ash fuel may 
allow longer intervals between cleaning.

CLINKERING:

 

[clinkers are silica (sand) or other impurities in the fuel that will form a hard mass during 

                                                Page 3  /  16

Summary of Contents for HP-0020S

Page 1: ...s and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COULD RESULT...

Page 2: ...ce Introduction 3 2 Structure instruction of pellet stove 7 3 Installation 8 4 Operating Instructions 10 5 Caution 11 6 Safety instructions 11 7 Maintenance 11 8 Troubleshooting 12 9 Warranty 13 10 Fi...

Page 3: ...d the warranty The Pellet Fuel Industries P F I has established standards for wood pellet manufacturers We recommend the use of pellets that meet or exceed these standards Please use a recommended pel...

Page 4: ...y result in property damage bodily injury or even death Contact your local building or fire official to obtain a permit and any information on installation restrictions and inspection requirements for...

Page 5: ...combustion air will result in the formation of soot which will collect on the glass the heat exchanger the exhaust vent system and may stain the outside of the house This is a dangerous situation and...

Page 6: ...door must be closed securely for proper and safe operation of the pellet stove Also ensure all gaskets on the door are checked and replaced when necessary KEEP ASH PAN FREE OF RAW FUEL DO NOT PLACE UN...

Page 7: ...ust temperature is still above 120 F 52 C Product performance introduction Pellet stove is advanced designed and has individual fresh air input and venting system Negative pressure burning technology...

Page 8: ...Structure instruction of pellet stove Note Page 8 16...

Page 9: ...chamber 6 window 7 hot wind channel 8 pellet grill 9 seal rope 10 fresh air chamber 11 ash cleaner 12 ash drawer 13 base 14 hopper 15 auger 16 auger motor 17 venting pipe 18 air input pipe 19 exhaust...

Page 10: ...that the electrical cord is not trapped under the appliance and that it is clear of any hot surfaces or sharp edges and also must be accessible If this power cord should become damaged a replacement...

Page 11: ...owner should connect with the local seller for the right installation When pellet stove is normal working the temperature on venting pipe surface can reach 200 C so the combustible things clothes and...

Page 12: ...r starts up f Depending on the heating desire fuel intake quantity can be adjusted from few to large by the fuel control switch SV3 At the same time adjust the switch SV1 and SV2 to blow the hot wind...

Page 13: ...erating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness must be under the unit 4 Do not open the stove door to pre...

Page 14: ...otor doesn t work Check the auger is blocked or not Check auger motor is blocked or not And the wires break or not Check the fasten screw between auger and motor loose or not B The orange lights are b...

Page 15: ...ke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dust in the stove with brush to ash drawer Attention the stov...

Page 16: ...Figure Electrical figure Page 16 16...

Reviews: