COMPLETION & STORAGE

1.  Switch off steam and vacuum pump switches, and unplug the unit. 
2.  Allow the unit to cool completely and then empty the unit and waste water collection tank of any remaining water. Never leave 

water in the unit whilst being stored. 

3.  Once the unit has cooled, wind the cable around the base of the feet on the unit and then wind the hose around the leg clips. 

Slot the steam plate into the side slots on the feet. 

HOW TO ASSEMBLE THE SPARE VACUUM CUP  

AND STEAM PLATE FILTER

Insert the vacuum seal (6) into the steam plate as shown. 

Insert the foam pump filter (7) as shown. 

1.1

1.2

1.3

1.4

1.5

2.1

2.2

2.3

2.4

1.  If you are right handed, hold the steam plate in your left hand and place flat against the ceiling where you wish to commence 

removing the Artex/paper.

2.  Leave the plate on the ceiling for a maximum of 10 seconds. The length of time will depend on the type of covering you are 

removing.

3.  If you are left handed you may find it easier to operate with the other hand.
4.  Move the steam plate to the section immediately next to where you have just been working and use a wallscraper to remove the 

section that has just been steamed.

5.  Empty the ceiling waste water tank when it starts to become full. It holds a total of 500ml of water and in 78 minutes should only 

require emptying once if a full tank is used.

6.  By working in this way you should be able to remove Artex/Paper continuously.
7.  You may have to leave the plate on the ceiling for longer periods or re-steam if not completely removed.
8.  Operate the steamer until steam is no longer produced (there is a safety cut out when water level gets too low), switch off the 

vacuum and leave for a minimum of 2 minutes before refilling. Allow to cool completely before packing away.

5mm

Summary of Contents for SS200

Page 1: ...t en aucun cas être tenue responsable en cas d utilisation de ce produit pour des travaux autres que ceux décrits dans ce manuel Lees deze instructies voor gebruik alstublieft zorgvuldig door Hartelijk bedankt voor uw aankoop van de Earlex Handenvrije behangstomer Om de beste resultaten te kunnen behalen dient u deze instructies zorgvuldig door te lezen VOOR u met het werk aanvangt Besteed ook spe...

Page 2: ...m plate When using on the ceiling remember to empty the waste water tank if it becomes full Always use and store upright If using on the stairs ensure boiler is in a safe and secure position The unit becomes hot in use Do not touch Only move by using the carry handle Always wear suitable protective clothing when operating the stripper A small amount of water will be expelled from a small hose in t...

Page 3: ...let to prevent steam escaping when using the unit on walls 7 Screw on the other end of the main hose to the boiler and tighten by hand 8 Connect the rubber Boiler Vacuum Tube F from the the vacuum outlet of the main hose to the vacuum port on top of the unit 9 Place the end of the ceiling waste water hose into the waste water collection tank 10 The unit is now ready to operate Please see operation...

Page 4: ...ur left hand and place flat against the wall where you wish to commence removing the paper 2 Leave the plate against the wall for approximately 10 seconds The length of time will depend on the type of wall covering you are removing 3 If you are left handed you may find it easier to operate with the other hand 4 Move the steam plate to the section immediately next to where you have just been workin...

Page 5: ...2 Leave the plate on the ceiling for a maximum of 10 seconds The length of time will depend on the type of covering you are removing 3 If you are left handed you may find it easier to operate with the other hand 4 Move the steam plate to the section immediately next to where you have just been working and use a wallscraper to remove the section that has just been steamed 5 Empty the ceiling waste ...

Page 6: ... obstructions If the hose is blocked NEVER force the safety valve closed The base of my unit is leaking water This is the residue water valve which releases a small amount of water collected by the vacuum on the steam plate when working on the ceiling This happens to ensure the safe running of the unit A maximum of 45ml of water will be expelled from this in 78 minutes Please protect all carpets a...

Page 7: ...ormity We declare that the unit SS200 conforms to 2006 95 EC EN60335 1 EN60335 2 54 2004 108 EC EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EMF EN 50366 Tim Hopper Technical Director MAINS CONNECTION This product is supplied with a specially prepared mains lead if the cord is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order to avoid a hazard P...

Reviews: