background image

4

OPERATION

DANGER FROM STEAM

 The unit has been designed for safe and fast removal of wallpaper but you must be aware at all times that 

steam is being produced and it can burn.

FILLING

WARNING: BEWARE OF HOT WATER DISCHARGE PRIOR TO STEAM EMISSION.
DO NOT:

•  Over-tighten the filler cap.
•  Overfill the unit by tilting the unit as hot water may be forced up the hose.
•  Leave unattended.

1.  Remove filler cap on top of the boiler and fill to the top with clean water, preferably hot. Do not tilt the unit when filling. If refilling 

the unit, ensure that itis disconnected from the main power

2.  If filled to the maximum (point of overflow) 5 litres, the stripper will operate for approximately 78 minutes before requiring refilling. 

It will take longer to commence steaming on a maximum fill, taking up to 15 minutes.

3.  Always replace the filler cap after filling. The cap only needs to be hand tight.
4.  The capacity of 5 litres (9 pints) provides approximately 78 mins steaming time before the safety cut-out operates. For 

a shorter steaming time use less water.

5.   Connect mains lead to the power socket and switch on the steam switch only, indicated by this symbol. It will take 

between 8 - 15 minutes (approx.) for the unit to start producing steam depending on the temperature and the quantity 
of water used. 

WARNING - Hot water discharge before steam is produced.

6.  Once steam is produced at the steam plate, you will need to switch the vacuum pump on, indicated by this symbol. 

You are then ready to commence operation. Make sure that the motor air inlet on the base of the unit is not blocked 
by the dustsheet as this will cause the motor to overheat. The motor is fitted with a re-setting thermal cut-out. If thermal cut-out 
is activated, please allow 15 minutes for the unit to reset.

STRIPPING

Remember to check a small area first.

WALLS

1.  If you are right handed, hold the steam plate in your left hand and place flat against the wall where you wish to commence 

removing the paper.

2.  Leave the plate against the wall for approximately 10 seconds. The length of time will depend on the type of wall covering you 

are removing.

3.  If you are left handed you may find it easier to operate with the other hand.
4.  Move the steam plate to the section immediately next to where you have just been working and use a wallscraper to remove the 

section that has just been steamed.

5.  By working in this way you should be able to remove paper continuously.
6.  Operate the steamer until steam is no longer produced (there is a safety cut out when water level gets too low), switch off the 

vacuum pump and boiler switch, and then leave for a minimum of 2 minutes before refilling. Allow to cool completely before 
packing away.

CEILINGS

Please note: While using the steam plate on the ceiling the unit will expel a small amount of water out of the base of the 
unit from the vacuum pump exhaust hose onto the surface below. Ensure that all floor surfaces are protected by dust 
sheets or plastic.

PREPARATION

If the plaster underneath the Paper or Artex is in a poor state of repair, care must be taken. If the plaster is old or cracked, the 
steam may penetrate, causing the plaster to “blister” or fall out. Check the plaster first and do not continue if this is unsound.

1.  In order to achieve the fastest result it is best to gently score the wallpaper to 

be removed before operating the stripper.

2.  If you have heavily embossed paper or painted paper this is essential. 
3.  Perforate the paper using a perforator tool, or alternatively score the paper in a 

criss-cross pattern approximately 6 inches apart with the edge of a wallscraper. 
A perforator tool is extremely useful for large surface areas and is available to 
buy through the online shop www.earlex.co.uk. For further availability please call 
our Customer Care Line on 01483 454666 quoting part number PPF1, or email  
[email protected] 

4.  As with all decorating, care should be taken to protect carpets and furniture 

with covers.

Summary of Contents for SS200

Page 1: ...t en aucun cas être tenue responsable en cas d utilisation de ce produit pour des travaux autres que ceux décrits dans ce manuel Lees deze instructies voor gebruik alstublieft zorgvuldig door Hartelijk bedankt voor uw aankoop van de Earlex Handenvrije behangstomer Om de beste resultaten te kunnen behalen dient u deze instructies zorgvuldig door te lezen VOOR u met het werk aanvangt Besteed ook spe...

Page 2: ...m plate When using on the ceiling remember to empty the waste water tank if it becomes full Always use and store upright If using on the stairs ensure boiler is in a safe and secure position The unit becomes hot in use Do not touch Only move by using the carry handle Always wear suitable protective clothing when operating the stripper A small amount of water will be expelled from a small hose in t...

Page 3: ...let to prevent steam escaping when using the unit on walls 7 Screw on the other end of the main hose to the boiler and tighten by hand 8 Connect the rubber Boiler Vacuum Tube F from the the vacuum outlet of the main hose to the vacuum port on top of the unit 9 Place the end of the ceiling waste water hose into the waste water collection tank 10 The unit is now ready to operate Please see operation...

Page 4: ...ur left hand and place flat against the wall where you wish to commence removing the paper 2 Leave the plate against the wall for approximately 10 seconds The length of time will depend on the type of wall covering you are removing 3 If you are left handed you may find it easier to operate with the other hand 4 Move the steam plate to the section immediately next to where you have just been workin...

Page 5: ...2 Leave the plate on the ceiling for a maximum of 10 seconds The length of time will depend on the type of covering you are removing 3 If you are left handed you may find it easier to operate with the other hand 4 Move the steam plate to the section immediately next to where you have just been working and use a wallscraper to remove the section that has just been steamed 5 Empty the ceiling waste ...

Page 6: ... obstructions If the hose is blocked NEVER force the safety valve closed The base of my unit is leaking water This is the residue water valve which releases a small amount of water collected by the vacuum on the steam plate when working on the ceiling This happens to ensure the safe running of the unit A maximum of 45ml of water will be expelled from this in 78 minutes Please protect all carpets a...

Page 7: ...ormity We declare that the unit SS200 conforms to 2006 95 EC EN60335 1 EN60335 2 54 2004 108 EC EN55014 1 EN55014 2 EN61000 3 2 EN61000 3 3 EMF EN 50366 Tim Hopper Technical Director MAINS CONNECTION This product is supplied with a specially prepared mains lead if the cord is damaged it must be replaced by the manufacturer its service agent or similar qualified persons in order to avoid a hazard P...

Reviews: