background image

The material contained in this document is the property of Electronics & Innovation Ltd., it is 
subject to change without notice.  
 
September 2010                                                                                                                           
 

Revision A 

 

 

Table 1-1. SPECIFICATIONS 

 

FREQUENCY COVERAGE: 

300 kHz to 35 MHz. 

GAIN: 

60 dB min, ±1.5 variation. 

CLASS A LINEAR OUTPUT: 

Nominal 1000 watts. 

SATURATED RF POWER OUTPUT: 

1500 Watts min 

INPUT IMPEDANCE 

50 ohms, VSWR, 1.5:1 Maximum. 

OUTPUT IMPEDANCE: 

50 ohms, VSWR, 2.5:1 Maximum 

STs  STABILITY: 

Continuous operation into any load or 
source impedance. 

PROTECTION: 

Unit will withstand a + 13 dBm input 
signal (1.0 Volts RMS) for all output load 
conditions, without damage. 

POWER OUTPUT METER: 

True RMS power detection.  ±5% of full 
scale accuracy. 

POWER REQUIREMENTS: 

3  208 VAC 47-63 Hz. 30 Amps 

SIZE: 

30 X 24 X 62 inches  L x W X H 
762 X 210 x 1575 mm.  L x W x H 

WEIGHT: 

610 pounds 277 kg 

CONNECTORS: 

OPERATING   TEMPERATURE: 

– 30 C 

RACK  MOUNTING: 

 

 
 

Chapter 2 Operation 

 
2.1 INTRODUCTION 

 
The  A1000 RF amplifier is used to amplify the RF level of  signal sources in the 
300 KHz to 35 MHz range. No tuning or any other form of adjustment is required.  
 
The  A1000  produces  rated  power  output  at  its  output  connector,  regardless  of 
load impedance. Any power reflected due to output load mismatch is absorbed in 
the  amplifier.  Therefore,  although  the  output  impedance  is  50  ohms  (maximum 
VSWR: 2.5:1), the amplifier will work into any load impedance. 
 
 
 
 
 

Summary of Contents for A 1000

Page 1: ...ber 2010 Revision A 1 A 1000 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these voltages and be t...

Page 2: ...lly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cos...

Page 3: ...SSB pulse and any complex modulation signals The amplifier has 60 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is prot...

Page 4: ...conditions without damage POWER OUTPUT METER True RMS power detection 5 of full scale accuracy POWER REQUIREMENTS 3 208 VAC 47 63 Hz 30 Amps SIZE 30 X 24 X 62 inches L x W X H 762 X 210 x 1575 mm L x...

Page 5: ...hieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument b The unit should not be driven at an input of over 1 dBm for a period of greater than one minute ii...

Page 6: ...ricted If the fault persists please contact Field Service 2 3 3 RS 232 Interface The A500 features a standard RS 232 serial interface suitable for connection to a PC or host system The communication p...

Page 7: ...BNC port The driver output signal is fed through a length of coaxial cable to the input of the IPA the output is fed to the power amplifier splitter This splitter has four outputs Each output is then...

Page 8: ...t is subject to change without notice September 2010 8 Revision A There are three switch mode power supply modules that provide a 42 VDC 300 ampere source Another provides 24 VDC outputs and provides...

Page 9: ...riodic maintenance The instrument is unconditionally stable and is fail safe under all load conditions Damage can only be externally caused by the incorrect selection of the AC supply voltage or by an...

Page 10: ...nect a sweep generator capable of sweeping the frequency range 300 KHz to 35 MHz to the input connector c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at th...

Page 11: ...D151 e Attenuator 60 dB 1000 Watts Bird Figure 4 1 Gain Measurement 2 Connect the equipment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0m...

Page 12: ...full deflection Rotate the step attenuator CCW so that the output is reduced by 60 dB g Reconnect the A1000 into the test set up of Figure 4 1 h Place the A1000 power switch to the ON position i Obse...

Page 13: ...place in a rigid outer box of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support for projecting parts to relieve these of unneces...

Reviews: