The  A  1000  is  a  broadband  solid  state  amplifier  covering  the  frequency  spectrum  from 
300  KHz  to  35  MHz.  It  is  rated  at  1000  watts  of  RF  power  with  low  harmonic  and 
intermodulation  distortion.  Over  1500  watts  of  saturated  power  can  be  produced  with 
increased  distortion  products.  A  linear  Class  A  design,  the  A1000  will  amplify  inputs  of 
AM, FM, SSB, pulse and any complex modulation signals. The amplifier has 60 dB gain, 
it  is  unconditionally  stable  and  will  not  oscillate  even  with  combinations  of  mismatched 
source  and  load  impedance.  It  is  protected  against  failure  due  to  output  load  mismatch 
and/or overdrive. 
 
RMS forward and reverse powers are monitored by a front panel meter. An integral power 
supply permits operation from 208 V three phase AC power/ max 30 Amps.  
 
 

1.2     INSTRUMENTATION IDENTIFICATION 

 
Each amplifier is identified by a serial number tag on the back panel of the unit. Both the 
model number and the serial number should be quoted to identify specific unit.  
 

1.3      SPECIFICATIONS 

 
Physical and electrical specifications are listed in Table 1-1 below 
 

Summary of Contents for A 1000

Page 1: ...ber 2010 Revision A 1 A 1000 Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these voltages and be t...

Page 2: ...lly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cos...

Page 3: ...SSB pulse and any complex modulation signals The amplifier has 60 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is prot...

Page 4: ...conditions without damage POWER OUTPUT METER True RMS power detection 5 of full scale accuracy POWER REQUIREMENTS 3 208 VAC 47 63 Hz 30 Amps SIZE 30 X 24 X 62 inches L x W X H 762 X 210 x 1575 mm L x...

Page 5: ...hieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument b The unit should not be driven at an input of over 1 dBm for a period of greater than one minute ii...

Page 6: ...ricted If the fault persists please contact Field Service 2 3 3 RS 232 Interface The A500 features a standard RS 232 serial interface suitable for connection to a PC or host system The communication p...

Page 7: ...BNC port The driver output signal is fed through a length of coaxial cable to the input of the IPA the output is fed to the power amplifier splitter This splitter has four outputs Each output is then...

Page 8: ...t is subject to change without notice September 2010 8 Revision A There are three switch mode power supply modules that provide a 42 VDC 300 ampere source Another provides 24 VDC outputs and provides...

Page 9: ...riodic maintenance The instrument is unconditionally stable and is fail safe under all load conditions Damage can only be externally caused by the incorrect selection of the AC supply voltage or by an...

Page 10: ...nect a sweep generator capable of sweeping the frequency range 300 KHz to 35 MHz to the input connector c Adjust the output level of the sweep generator so that a 50 ohm video detector connected at th...

Page 11: ...D151 e Attenuator 60 dB 1000 Watts Bird Figure 4 1 Gain Measurement 2 Connect the equipment as shown in Figure 4 1 then proceed as follows a Set the oscilloscope to DC Time cm to Ext X and gain to l0m...

Page 12: ...full deflection Rotate the step attenuator CCW so that the output is reduced by 60 dB g Reconnect the A1000 into the test set up of Figure 4 1 h Place the A1000 power switch to the ON position i Obse...

Page 13: ...place in a rigid outer box of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support for projecting parts to relieve these of unneces...