background image

 

The material contained in this document is the property of Electronics & Innovation Ltd., it is 
subject to change without notice.  
 

July 2012                                                                                                                      Revision I 

 

 

Table 1-1. SPECIFICATIONS 

 

FREQUENCY COVERAGE: 

10 KHz to 12 MHz 

GAIN: 

50 dB min, ±1.5 variation 

CLASS A LINEAR OUTPUT: 

100 watts P1dB 

HARMONIC DISTORTION: 

< -25 dBc at 100 watts output 

SATURATED RF POWER OUTPUT: 

200W Min. 

from  30kHz - 4MHz; 

175W Min. 

from  10kHz - 10MHz; 

150W Min. 

from  10MHz - 12MHz 

INPUT IMPEDANCE 

50 ohms, VSWR, 1.5:1 Maximum 

OUTPUT IMPEDANCE: 

50 ohms, VSWR, 2:1 Maximum 

STs  STABILITY: 

Continuous operation into any load or 
source impedance 

PROTECTION: 

Unit will withstand a + 13dBm input 
signal (1.0 Volts RMS) for all output load 
conditions, without damage 

POWER OUTPUT METER: 

True RMS power detection.  ±3% of full 
scale accuracy from 20 KHz 

– 12 MHz 

POWER REQUIREMENTS: 

100 

– 240 VAC 47-63 Hz 

SIZE: 

5.3 x 16.5 x 18.4 inches  
13.5 x 41.9 x 46.7 cm 

WEIGHT: 

32.5 pounds 14.7 kg 

CONNECTORS: 

BNC 

OPERATING   TEMPERATURE: 

– 40 C 

RACK  MOUNTING: 

 

 
 
 

Chapter 2 Operation 

 
2.1 INTRODUCTION 

 
The 2100L RF amplifier is used to amplify the RF level of signal sources in the 10 
KHz to 12 MHz range. No tuning or any other form of adjustment is required.  
 
The 2100L will work into any load impedance. Into a short circuit or infinite load 
at  some  phase  angles  it  may  protect  itself  at  power  greater  than  80%  rated 
power  output.  Any  power  reflected  due  to  output  load  mismatch  is  absorbed  in 
the  amplifier.  Therefore,  although  the  output  impedance  is  50  ohms  (maximum 
VSWR: 2:1), the amplifier will work into any load impedance. 
 
 

Summary of Contents for 2100L

Page 1: ...hout notice July 2012 Revision I 1 2100L Broadband Power Amplifier HIGH RF VOLTAGES MAY BE PRESENT AT THE OUTPUT OF THIS UNIT All operating personnel should use extreme caution in handling these volta...

Page 2: ...ly operational such that it performs according to the original specifications free of charge to the original purchaser Should warranty service be required the unit must be returned to E I freight cost...

Page 3: ...M FM SSB pulse and any complex modulation signals The amplifier has 50 dB gain it is unconditionally stable and will not oscillate even with combinations of mismatched source and load impedance It is...

Page 4: ...put load conditions without damage POWER OUTPUT METER True RMS power detection 3 of full scale accuracy from 20 KHz 12 MHz POWER REQUIREMENTS 100 240 VAC 47 63 Hz SIZE 5 3 x 16 5 x 18 4 inches 13 5 x...

Page 5: ...ms indicated maximum input voltage is 5 times the level of the input signal required to achieve maximum output Input voltages in excess of 2 volts peak may permanently damage the instrument iii Connec...

Page 6: ...unrestricted If the fault persists please contact Field Service 2 3 3 RS 232 Interface The 2100L features a standard RS 232 serial interface suitable for connection to a PC or host system The communi...

Page 7: ...l from the input of the driver is coupled to the input of the MMIC front end The output signal of the MMIC is coupled to the gate of transistor Q1 The further amplified signal appearing at the drain o...

Page 8: ...12 Revision I 8 The main power supply unit provides a 48 VDC 12 ampere source It is a switch mode power supply unit The output feeds the PA and the 24 Volt DC power supply regulator This in turn provi...

Page 9: ...ocedure 4 2 1 Initial Check The following check can be made after repair and adjustments or whenever the condition of the unit is in question a Connect AC power supply Switch on power and observe that...

Page 10: ...surement of Gain 1 Equipment Required or equivalent a Osilloscope Tektronix T921 b Sweep Generator HP8601A c Signal Generator Exact Model 7060 d 50 ohm Detector Wavetek D151 e Attenuator 30 dB 200 Wat...

Page 11: ...el to full deflection Rotate the step attenuator CCW so that the output is reduced by 50 dB g Reconnect the 2100L into the test set up of Figure 4 1 h Place the 2100L power switch to the ON position i...

Page 12: ...aper or plastic and place in a rigid outer box of wood fiberboard or very strong corrugated cardboard Use ample soft packing to prevent movement Provide additional support for projecting parts to reli...