eamlab Studio300 User Manual Download Page 7

 

 

 

 

 

Ready to Power on 

 

After making all connections correctly we  are 
ready    to    turn    on    the      amplifier. 
 
You  just  made,  the  amplifier  performs  some 
set in the reset to ensure a safe operation, this 
is  true  both  in  power-on  switch-off. 
 
As sometimes happens the major problems of 
high power amplifiers take over at power on 
or 

power 

down. 

Our amplifiers HA series are designed not to 
lie 

in 

this 

unfortunate 

situation. 

 
Pressed the power switch on the front panel, 
the  two  LEDs 

ILP

TM

  (see  fig.  A)  will  flash  for 

about  3  seconds  and  then  stay  on  steady. 
These  LEDs  indicate  the  operating  status  of 
the protections that serve different functions 
listed below:

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
ILP

TM

 (intelligent lock power):  

 
At Power on: 

-  connect  the  speakers  out  after  about 

3  seconds    (delay  antibump).  The  LEDs 
become fixed after about 3sec. 
 

2- 

resets  the  parameters  of  current  and 

voltage  of  the  output  stages    to  ensure 
maximum efficency 
 

3- 

immediately disconnects the load in case of 

failure of the transistors 
 

4 -

 disconnect the load in the event of a short 

circuit on the output stages 
 

5 -

 disconnect the load in the event of a short 

circuit on the power cables 
 

6  -

  disconnect  the  load  in  the  event  of 

prolonged  clipping  without  damaging  the 
speakers. 

 

At the power off

 

1

immediately disconnects the outputs from 

the load

 

 

If the LEDs flash always

 

In  remote  eventually  that  something  can 
impair  circuit 

ILP

TM

  quickly  intervene 

immediately  disconnecting  the  load  and 
blocking  the  amplifier.  The  LED  or  two  LEDs 
(the  2  channels  have  2  independent  circuits 
ILP)  will  flash  warning  that  something  went 
wrong during the operation. 
 

note

:  the  circuit 

ILP

TM

 

also  intervenes  when 

the 

DC 

output offset should increase coming 

from the parameters set in the factory. 

 
 

Function and protection 

Summary of Contents for Studio300

Page 1: ...1 Model Studio300 HI END stereo power amplifier User manual English Models for Europe 230 Vac 50 Hz ...

Page 2: ...2 ...

Page 3: ...temperature inside the rooms very quickly Then install the unit in a well ventilated place avoiding placing various objects in front of these openings to prevent fire and damage Leave a space of at least 20 cm behind 20 cm on both sides and 30 cm above the top panel of the machine to avoid fire or other damage 6 The voltage used must be specified Using this product with a current whose voltage is ...

Page 4: ...lanced 25 Kohm single ended THD Vs freq 0 2 to 5Khz 20Khz S N ratio 110 db DF 180 150Hz 4 Ohm Max V output 43V Max current drive 42A Measure 470 x 250 x 310 mm Weight 28Kg Compsumption 230Vac full power 6 A Input connector XLR neutrik and RCA Output connector VBT binding post 8mm wire Line filter Schaffner 15 A protection THL SVCS ILP IDCL safety 90 thermal switch ...

Page 5: ...e damage to speakers connected Before the installation remove your amplifier taking care to keep it in the future if you ever require to be shipped to a service center EAMLAB to be overhauled or repaired Installation thanks to its ease of use there are no particular notes of difficult interpretation Before making any connections make sure that the amplifier is turned OFF preferably with the mains ...

Page 6: ...6 Pannel Front controls fig A 1 ILPTM intelligent lock power Indicates the operating status of amplifier Indicates the operating status of the thermal and DC protections 3 ON OFF Switch ...

Page 7: ...ecome fixed after about 3sec 2 resets the parameters of current and voltage of the output stages to ensure maximum efficency 3 immediately disconnects the load in case of failure of the transistors 4 disconnect the load in the event of a short circuit on the output stages 5 disconnect the load in the event of a short circuit on the power cables 6 disconnect the load in the event of prolonged clipp...

Page 8: ...groped to solve the problem alone but immediatamnete contact theservicecenter Any unauthorized intervention by EAMLAB immediately void the warranty THLTM thermal overload The thermal protection system THLTM is activated only in the case in which the operating temperature of the final stages exceeds the threshold of 90 The intervention THL will be signaled by the fixed LEDs on the front panel see f...

Page 9: ...9 Connecting schematics ...

Page 10: ...tain minimum the size of the cabinet while having available powers with extraordinary high current delivery The amplification of the signal is entrusted to 12 power devices of last generation for each channel capable of dissipating each one more than 15A of DC current These final together with all the active components of the circuit have been selected based on the data of bandwidth that we wanted...

Page 11: ...pedance Detecting Current Limiting Tutte le protezioni attive presenti nei circuiti di amplificazione sono progettate affinchè non possano intervenire in nessun modo sul segnale audio che potrebbe invece degradare come avviene in molti casi su amplificatori non progettati a dovere IDCL is a protection circuit that constantly monitors the output current of the power output by comparing it with the ...

Page 12: ...s the correct operation even in the event of excessive thermal stress The circuit is activated when the temperature on the heat sink reaches the threshold of 70 c and makes sure to keep it stable within a tolerance of 10 by acting on micro variations of the polarization of the final stages The two LEDs on the front panel indicate the operation of the circuit THL this is a condition that occurs aft...