eamlab Studio300 User Manual Download Page 6

 

 

 

Pannel Front controls:   

fig.A. 

 

1.

  ILP

TM

 

 

intelligent lock power

   

Indicates the operating status of 'amplifier 

Indicates the operating status of the  thermal and DC protections. 

3 . ON/OFF  Switch 

Summary of Contents for Studio300

Page 1: ...1 Model Studio300 HI END stereo power amplifier User manual English Models for Europe 230 Vac 50 Hz ...

Page 2: ...2 ...

Page 3: ...temperature inside the rooms very quickly Then install the unit in a well ventilated place avoiding placing various objects in front of these openings to prevent fire and damage Leave a space of at least 20 cm behind 20 cm on both sides and 30 cm above the top panel of the machine to avoid fire or other damage 6 The voltage used must be specified Using this product with a current whose voltage is ...

Page 4: ...lanced 25 Kohm single ended THD Vs freq 0 2 to 5Khz 20Khz S N ratio 110 db DF 180 150Hz 4 Ohm Max V output 43V Max current drive 42A Measure 470 x 250 x 310 mm Weight 28Kg Compsumption 230Vac full power 6 A Input connector XLR neutrik and RCA Output connector VBT binding post 8mm wire Line filter Schaffner 15 A protection THL SVCS ILP IDCL safety 90 thermal switch ...

Page 5: ...e damage to speakers connected Before the installation remove your amplifier taking care to keep it in the future if you ever require to be shipped to a service center EAMLAB to be overhauled or repaired Installation thanks to its ease of use there are no particular notes of difficult interpretation Before making any connections make sure that the amplifier is turned OFF preferably with the mains ...

Page 6: ...6 Pannel Front controls fig A 1 ILPTM intelligent lock power Indicates the operating status of amplifier Indicates the operating status of the thermal and DC protections 3 ON OFF Switch ...

Page 7: ...ecome fixed after about 3sec 2 resets the parameters of current and voltage of the output stages to ensure maximum efficency 3 immediately disconnects the load in case of failure of the transistors 4 disconnect the load in the event of a short circuit on the output stages 5 disconnect the load in the event of a short circuit on the power cables 6 disconnect the load in the event of prolonged clipp...

Page 8: ...groped to solve the problem alone but immediatamnete contact theservicecenter Any unauthorized intervention by EAMLAB immediately void the warranty THLTM thermal overload The thermal protection system THLTM is activated only in the case in which the operating temperature of the final stages exceeds the threshold of 90 The intervention THL will be signaled by the fixed LEDs on the front panel see f...

Page 9: ...9 Connecting schematics ...

Page 10: ...tain minimum the size of the cabinet while having available powers with extraordinary high current delivery The amplification of the signal is entrusted to 12 power devices of last generation for each channel capable of dissipating each one more than 15A of DC current These final together with all the active components of the circuit have been selected based on the data of bandwidth that we wanted...

Page 11: ...pedance Detecting Current Limiting Tutte le protezioni attive presenti nei circuiti di amplificazione sono progettate affinchè non possano intervenire in nessun modo sul segnale audio che potrebbe invece degradare come avviene in molti casi su amplificatori non progettati a dovere IDCL is a protection circuit that constantly monitors the output current of the power output by comparing it with the ...

Page 12: ...s the correct operation even in the event of excessive thermal stress The circuit is activated when the temperature on the heat sink reaches the threshold of 70 c and makes sure to keep it stable within a tolerance of 10 by acting on micro variations of the polarization of the final stages The two LEDs on the front panel indicate the operation of the circuit THL this is a condition that occurs aft...