background image

SCALE

HINGED

+EX

+SI

-SI

-EX

+SH

EX  Ω

SI Ω

NOTE

WT-3600

4000

1820

0.5

2

Y

RED GRN WHT BLK

YEL

500680

DCS-302

300

140

0.9

1/side

N

RED GRN WHT BLK

YEL

500317

TB5 (RIGHT CHANNEL)

OR

BLU

x2

TB4 (LEFT CHANNEL)

EDS-400

400

180

1.1

1

N

RED GRN WHT BLK

YEL

500317

LP-4310

1

Y

LP-4320

2

Y

LP-4300 #1

4410

2000

2

4

N

RED GRN WHT BLK

YEL

500711

LP-4300 #2

8820

4000

2

4

N

RED GRN WHT BLK

YEL

500785

LP-4300 #3

17640

8000

2

4

N

RED GRN WHT BLK

YEL

500680

LP-4300 HD

20000

9072

2

4

N

RED GRN WHT BLK

YEL

ECS150x

300

140

3

1

Y

GRN RED WHT BLK

YEL

500645

WP1000 #1

330

150

1

4

N

RED GRN WHT BLK

YEL

500736

or 500737

WP1000 #2

661.5

300

1

4

N

RED GRN WHT BLK

YEL

500725

WP1000 #3

1323

550

1

4

N

RED GRN WHT BLK

YEL

500722

DS750

750

340

2

1

N

RED GRN WHT BLK

YEL

500639

ECS400

400

181

1

Y

GRN RED WHT BLK

YEL

500645

1K CELL

ECS402

400

181

1

Y

GRN RED WHT BLK

YEL

500747

HC1000

2000

907

1

Y

GRN WHT RED

BLK

YEL

500680

C3600

4000

1814

4

N

RED GRN WHT BLK

YEL

500680

C7200

8000

3629

4

N

RED GRN WHT BLK

YEL

500680

SC1000/SC1000B

1000

2200

2

4

N

RED GRN WHT BLK

YEL

500783

Older revisions

WT3600

4000

1814

0.5

2

Y

RED GRN WHT BLK

YEL

500123

HC3600

4000

1814

1

Y

RED GRN WHT BLK

YEL

500123

500535 30' CABLE

HC7200

8000

3629

1

Y

RED GRN WHT BLK

YEL

500113

ECS150x

300

140

3

1

Y

RED WHT GRN BLK

YEL

N/A

OBS LOADCELL

FULL-SCALE 

lb

FULL-SCALE 

kg

FULL-SCALE 

mV/V

# LOAD 

CELLS

LOAD 

CELL 

IHPN

Summary of Contents for EI-250

Page 1: ...Economy Electronic Weight Indicator INSTALLATION OPERATION MANUAL 10 8 19 V1 0 Eagle Microsystems Inc 366 Circle of Progress Pottstown PA 19464 Phone 610 323 2250 Fax 610 323 0114 www eaglemicrosyste...

Page 2: ...Page Intentionally left blank...

Page 3: ...1 III INSTALLATION AND STARTUP 2 IV GENERAL OPERATION 2 V CALIBRATION AND ZERO PROCEDURE 3 VI ADJUSTING REMAINING WEIGHT TARE 3 VII CONFIGURATION 3 VIII PARAMETER LIST 4 IX TECHNICAL INFORMATION 5 WI...

Page 4: ...ty five 25 feet or less Max weight 9990 lbs kgs Resolution 0 1 0 2 0 5 1 2 or 5 Graduations 1000 typical Update rate Four sec normal once ten seconds low power mode Display four digit LCD 0 5 Push but...

Page 5: ...the enclosure and place 2 D cell batteries in the holder at the rear of the instrument 5 Bring the load cell cable into the enclosure through the strain relief at the bottom of the enclosure and wire...

Page 6: ...nter select pushbutton Look for the small arrow on the left side of the display 2 Press and HOLD the up or down arrow for three seconds the arrow on the left side of the display will start flashing 3...

Page 7: ...en weight is removed P116 Operational threshold 0 Full Scale Automatically displays remaining if weight goes over the threshold P117 Full scale User defined based on scale capacity limits Use the full...

Page 8: ...lor codes TB1 SI Positive Signal TB1 SI Negative Signal TB1 EX Negative Exitation S4 Gain A Both open 56 mV V B 75 A 1 35 AB 2 28 Set as close as possible to scale mV V S4 Gain B S4 Setup Enter config...

Page 9: ...736 or 500737 WP1000 2 661 5 300 1 4 N RED GRN WHT BLK YEL 500725 WP1000 3 1323 550 1 4 N RED GRN WHT BLK YEL 500722 DS750 750 340 2 1 N RED GRN WHT BLK YEL 500639 ECS400 400 181 1 Y GRN RED WHT BLK Y...

Page 10: ...User Changes Parameters requiring option cards Default values User Changes P111 Resolution P501 Relay Setpoint P112 Averaging P601 Analog Output F S P113 Auto Zero Off P116 Operational Threshold P117...

Reviews: