5
Wear hearing protection.
Wear eye protection.
Wear respiratory protection.
Read the instruction manual
BEFORE USING THIS AIR TOOL
OPERATING INSTRUCTIONS
Add oil throughout the day when using. We highly recommend use of an in-line mini oiler to
accomplish this. Blow out air line to clear dirt and moisture. The air regulator knob can be
used as a throttle if there is no other means of regulating air. Turn the knob all the way in
and adjust outward until desired speed is reached.
Hold the tool away from work when starting. Set it down on the work evenly and make the
cut. When cut is completed, lift tool away from work before stopping the motor. Use only
discs rated at 20000 RPM or higher. Accessory retainers should be used to prevent ejec-
tion of the accessory which might injure persons.
EXCEPTION: Retainers need not be used if in compliance with acceptable safety codes. In
such cases, to avoid injury, the trigger should never be depressed unless the accessory is
held firmly against the work piece. Accessory should be removed when tool is not in use.
To ensure long life be sure to oil the tool daily. Pour 4 drops of Eagle air tool (SEA 20 non
detergent) oil into the air inlet, and then run the tool for a few seconds to clean.
If tool is an impact wrench fitted with a “Zirc” grease fitting:
The hammer mechanism of this tool also needs to be greased from time to time (depending
on usage). The tool is equipped with grease fitting for this purpose; use this connection to
re-grease the tool using Eagle impact wrench grease.
PLEASE USE EAGLE SEA 20 NON DETERGENT OIL
TROUBLESHOOTING
SYMPTOMS
CAUSE
REMEDY
Air tool does not
run or runs slow.
Lack of lubrication.
Lubricate as per instructions.
Dirt in tool.
Clean with mixture of 50/50 tool
oil/solvent. Lubricate after cleaning.
Insufficient air pressure.
Check regulator and air supply for
leaks. Check compressor to make
sure it operates at correct pressure.
Make sure air hose is properly sized
and that multiple hoses are not
connected to same outlet. Check air
hose for leaks and repair.
Rotor blades worn or motor
bearing worn or dirty.
Replace blades, inspect clean or
replace bearing.
IMPACT WRENCH
does not impact or
impacts slowly.
See causes (above).
See remedies (above).
Broken or worn impact
mechanism.
Inspect and repair as required.