background image

 

 

 

 
 

"001--512"; Press “ENTER” to confirm exit, press “ESC” to abandon exit. 

3.

 

To accept the mainframe synchronous (from the models), you have to set the address value as 

"001". 

4.

 

In  the address value situations, if you install DMX  controller without connecting, the display 

will  twinkle;  if  you  install  connecting  DMX  controller,  the  display  will  not  twinkle;  but  the 

signal light will twinkle ,only the signal is exit. 

二、

 

DN. Pr. 

DMX Pre-Setting

 

This function let you to choose different operating modes. 

1.

 

Press the "up" or "down" keys to browse other menus. 

2.

 

Press  “ENTER”  to  enter,  then  press  “UP”  or  “DOWN”  and  choose  “nod.1”  or  “nod.2”,then 

press “enter” to save and exit or press “ESC” to exit directly. 

Nod.1: [mode 1] the normal channel value controlling 

Nod.2: [mode 1] the fewer channel value controlling   

3.

 

To  accept  the  mainframe  synchronous  (from  the  models),  you  have  to  pre-set  the  DMX  as 
“nod.1”. 

三、

 

Testing Procedures

 

This function allows you to take inner demonstration procedures without external connector. This setting 

will be kept up, If you don’t exit the testing procedure, you will automatically enter the testing procedure, 

once you start up it every time. 

Press “UP” or “DOWN” keys to browse other menus, press “ENTER” to enter. 

1. nod. 1 [testing mode 1] 

Press “ UP” or “DOWN” to select other modes, press “ ENTER” to enter, showing “RUN” 
testing work. If you need to exit, please press “ ESC”. 
2. nAst:

 [mainframe controlling] 

This  function  allows  you  to  test  directly,  which  don’t  require  mainframe  to  send  DMX  synchronous 

signal to deputy plane. 

Press  “UP”  or  “DOWN”  to  select  other  modes,  press  “ENTER”  to  enter,  appear  “ON”  as  mainframe 

sending out signal, the DMX signal light on. Appear “OFF” as mainframe don’t sending out signal, the 

DMX signal light crush out, press “ ENTER” to save and exit, press “ESC” to exit directly. After setting 
“ON”, you have to cut off external DMX controller, which don’t allow two or more mainframes with 

same setting in the same connecting road. 

四、

 

Audi 

[ Sound- controlled Stimulating ] 

This function allows you to use sound stimulated testing prosecutor. 

1.

 

Press “ UP” or “DOWN” to browse other menus. 

2.

 

Press  “  ENTER”  to  enter,  then  press  “UP”  or  “DOWN”  and  select  “ON”  or 
“OFF”  showing  whether  using  sound  stimulating  or  not  while  testing..  “ON”

 

shows  to  use  sound  controlling,  “OFF”  shows  not  to  use  sound  controlling, 
controlled automatically in the testing mode. After setting “ON”, the audio singal 
light will twinkle together with the music in the testing procedure. 

五、

r.Pan.

 [ Pan reverse in horizontal ] 

This function allows you to reverse in horizontal. 

Press “ENTER” to enter, use “UP” or “DOWN”, if you need to reverse, please select “ON”; if 

Summary of Contents for 1000

Page 1: ...SF SH04 Spot 1200W 220V 50 60HZ 18CH Moving Head Light USER MANUAL ...

Page 2: ...ction It combines mechanism electron and optics and adopted international standard DMX 512 signal Technology Parameter Voltage AC220V 240V Frequency 50 60HZ Power 1500W HMI1200 lamp Channel 18channels Color Temperature 7000K Applied modern ABS engineer plastic housing Digital display can be reversed 180 degree suitable for different installation 16Bit super smooth scan pan 540 tilt 270 8Bit or16Bi...

Page 3: ...nd maintenance persons must get familiar with the light performance before operation so that to avoid damage to the machine Please check if there is any damage during transportation before first usage Before changing the bulb please make sure the electric power is cut off and the lamp is cooled off Bulb temperature can reach above 200 degree Push the maintenance cover open the small bulb lid encas...

Page 4: ...fer line from 5 core to 3 core will be needed if the controller you use is 5 core outlet plug Please refer to Appendix 2 HMI 1200W lamp is discharge lamp it is fully illuminated about 5 10 minutes after power is on In the meantime please restart about 10 minutes after power is off When power is on the equipment will undertake self examination and can undertake operation after the self examination ...

Page 5: ... core and 5 core XLR control outlet plug 3 3 3 5 3 5 3 core plug 3 core plug 5 core plug 3 core pl ug 5 corepl ug 3 core pl ug DMX512 signal circuit Pin 1 screen Pin 2 signal Pin 3 signal The Instruction Manual for Computer Lightings The menu of control display boards is designed for various types of computer lights equipped with multiple functions of control mode and controlled easily For some sp...

Page 6: ...TER to enter 1 nod 1 testing mode 1 Press UP or DOWN to select other modes press ENTER to enter showing RUN testing work If you need to exit please press ESC 2 nAst mainframe controlling This function allows you to test directly which don t require mainframe to send DMX synchronous signal to deputy plane Press UP or DOWN to select other modes press ENTER to enter appear ON as mainframe sending out...

Page 7: ...ou to reverse in vertical Press ENTER to enter use UP or DOWN if you need to reverse please select ON if you don t need to reverse please select OFF press ENTER to save and exit press ESC to exit directly 七 rset device replacement This function allows you to restart up device to come back to original standard setting Press ENTER to confirm Esc Down Up Enter ...

Reviews: