3
●
The original address code set-up before the products leave the factory:
patterns and colors streamline, X,Y axis is the positive direction
●
Use the XLR-XLR cable from the signal output port of the consol to connect the signal input port of
the first light, connect the signal output port of the first light with the signal input port of the second
light, and so on, until all lights are connected. Then connect the terminal plug with the signal output port
of the last light. (Figure Appendix 1)
Warning: Please remember the signal output of the last light should be connected with the terminal plug.
This plug add a resistance around 120
Ω
between 2nd and 3rd pin of CANON plug. Use this plug could
effectively avoid the signal reflection created during DMX512 signal transmission.
●
1200 Moving Head Light uses 3 core XLR outlet(plug). A transfer line from 5 core to 3 core will be
needed if the controller you use is 5 core outlet (plug). (Please refer to Appendix 2)
●
HMI 1200W lamp is discharge lamp, it is fully illuminated about 5-10 minutes after power is on. In
the meantime, please restart about 10 minutes after power is off.
●
When power is on, the equipment will undertake self-examination, and can undertake operation
after the self-examination is finished.
●
Please don’t shake the equipment during operation.
●
Please do not use the light continuously for over 8 hours.
○
Control Channel
1200Moving Head Light adopts international standard DMX512 signal. There are 10 control channels
and the detailed information of control is as follow:
● Table of 18 control channels
Channel
0 – 255
Control content
1
Strobe
0 – 255
Shutter open/strobe slo
w~fast 10-10times/second
2
Vector mode
0 – 255
…..
3
PAN
0 – 255
0 – 255, pan 0-540
0
scan
4
Tilt
0 - 255
0 – 255, tilt 0-270
0
scan
5
X, Y speed adjustment
0 – 255
0 – 255 adjust speed from slow to fast
6
Color Wheel A
0 - 255
0 – 255, tilt 0-270
0
scan
7
Color Wheel B
0 – 255